Comparison of exercise stress testing with dobutamine stress echocardiography and exercise technetium-99m isonitrile single photon emission computerized tomography for diagnosis of coronary artery disease

被引:0
|
作者
Oguzhan, A [1 ]
Kisacik, HL [1 ]
Ozdemir, K [1 ]
Altunkeser, BB [1 ]
Durmaz, T [1 ]
Altinyay, E [1 ]
Kural, T [1 ]
Korkmaz, S [1 ]
Kir, M [1 ]
Kutuk, E [1 ]
Goksel, S [1 ]
机构
[1] ANKARA YUKSEK IHTISAS HOSP,DEPT CARDIOL,ANKARA,TURKEY
来源
JAPANESE HEART JOURNAL | 1997年 / 38卷 / 03期
关键词
dobutamine; exercise; stress echocardiography; technetium 99m isonitrile single-photon emission computed tomography;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To compare the value of exercise electrocardiography with dobutamine stress echocardiography and exercise technetium-99m isonitrile single-photon emission computed tomography for coronary artery disease, 70 patients with either suspected or proven coronary artery disease underwent dobutamine stress echocardiography, exercise technetium-99m isonitrile single-photon emission computed tomography (mibi-SPECT) and treadmill exercise electrocardiography (EGG). Dobutamine echocardiography and exercise mibi-SPECT revealed a higher overall sensitivitiy than exercise testing (90 vs 57%, p < 0.001; 96 vs 57%, P < 0.001, respectively). Dobutamine stress echocardiography showed a higher specificity than both exercise mibi-SPECT and treadmill exercise electrocardiography (90 vs 71%, P > 0.05; 90 and 62% p < 0.05, respectively) but the difference between dobutamine stress echocardiography and exercise mibi-SPECT was not statistically significant. Diagnostic accuracy of dobutamine stress echocardiography and exercise mibi-SPECT was higher than that of exercise testing (90 vs 59%, P < 0.001; 89 vs 59%, P < 0.001, respectively). Dobutamine stress echocardiography and exercise mibi-SPECT have superiority over exercise testing in the diagnosis of coronary artery disease and dobutamine stress echocardiography is an alternative for exercise mibi-SPECT.
引用
收藏
页码:333 / 344
页数:12
相关论文
共 50 条
  • [21] Dobutamine stress thallium-201 single-photon emission tomography versus echocardiography for evaluation of the extent and location of coronary artery disease late after myocardial infarction
    Elhendy, A
    Bax, JJ
    van Domburg, RT
    Valkema, R
    Cornel, JH
    Reijs, AEM
    Krenning, EP
    Roelandt, JRTC
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (05) : 467 - 473
  • [22] The diagnostic value of adenosine stress-contrast echocardiography for diagnosis of coronary artery disease in hypertensive patients: Comparison to Tl-201 single-photon emission computed tomography
    Aggeli, Constadina
    Christoforatou, Euaggelia
    Giannopoulos, Georgios
    Roussakis, Georgios
    Kokkinakis, Christos
    Barbetseas, John
    Vlachopoulos, Charalambos
    Stefanadis, Christodoulos
    AMERICAN JOURNAL OF HYPERTENSION, 2007, 20 (05) : 533 - 538
  • [23] Safety, hemodynamic profile, and feasibility of dobutamine stress technetium myocardial perfusion single-photon emission CT imaging for evaluation of coronary artery disease in the elderly
    Elhendy, A
    van Domburg, RT
    Bax, JJ
    Valkema, R
    Reijs, AEM
    Krenning, EP
    Roelandt, JRTC
    CHEST, 2000, 117 (03) : 649 - 656
  • [24] Prognostic Value of Dipyridamole Stress Myocardial Contrast Echocardiography: Comparison With Single Photon Emission Computed Tomography
    Dawson, Dana
    Kaul, Sanjiv
    Peters, Dawn
    Rinkevich, Diana
    Schnell, Gregory
    Belcik, J. Todd
    Wei, Kevin
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (08) : 954 - 960
  • [25] Head-to-head comparison of exercise stress testing, pharmacologic stress echocardiography, and perfusion tomography as first-line examination for chest pain in patients without history of coronary artery disease
    Giovanni M. Santoro
    Roberto Sciagrà
    Piergiovanni Buonamici
    Nicola Consoli
    Vincenzo Mazzoni
    Francesca Zerauschek
    Gianni Bisi
    Pier Filippo Fazzini
    Journal of Nuclear Cardiology, 1998, 5 : 19 - 27
  • [26] Detection of a biphasic response of hibernating myocardium by dobutamine-stress electrocardiography gated technetium-99m-tetrofosmin single photon emission computed tomography - A case report
    Yamagishi, H
    Akioka, K
    Hirata, K
    Sakanoue, Y
    Toda, I
    Yoshiyama, M
    Teragaki, M
    Takeuchi, K
    Yoshikawa, J
    Ochi, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1999, 63 (09): : 688 - 691
  • [27] Diagnostic accuracy of contrast echocardiography during adenosine stress for detection of abnormal myocardial perfusion: a prospective comparison with technetium-99 m sestamibi single-photon emission computed tomography
    Abdelmoneim, Sahar S.
    Bernier, Mathieu
    Dhoble, Abhijeet
    Moir, Stuart
    Hagen, Mary E.
    Ness, Sue Ann C.
    Pellikka, Patricia A.
    Abdel-Kader, Samir S.
    Mulvagh, Sharon L.
    HEART AND VESSELS, 2010, 25 (02) : 121 - 130
  • [28] Additive value of low-dose dobutamine to technetium-99m sestamibi-gated single-photon emission computed tomography for prediction of wall motion improvement in patients undergoing coronary artery bypass graft
    Zafrir, N
    Arditi, A
    Ben-Gal, T
    Solodky, A
    Hassid, Y
    Sulkes, J
    Battler, A
    CLINICAL CARDIOLOGY, 2003, 26 (11) : 530 - 535
  • [29] Head-to-head comparison of exercise stress testing, pharmacologic stress echocardiography, and perfusion tomography as first-line examination for chest pain in patients without history of coronary artery disease
    Santoro, GM
    Sciagra, R
    Buonamici, P
    Consoli, N
    Mazzoni, V
    Zerauschek, F
    Bisi, G
    Fazzini, PF
    JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (01) : 19 - 27
  • [30] Incremental value of stress echocardiography and computed tomography coronary calcium scoring for the diagnosis of coronary artery disease
    Wael AlJaroudi
    Mohamad Jihad Mansour
    Maroun Chedid
    Omar Hamoui
    Joseph Asmar
    Layal Mansour
    Elie Chammas
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1133 - 1139