The compliance with and knowledge about radiation protection in operating room personnel: a cross-sectional study with a questionnaire

被引:42
作者
Jentzsch, Thorsten [1 ]
Pietsch, Christiane M. [1 ,2 ]
Stigler, Brigitte [1 ]
Ramseier, Leonhard E. [3 ]
Seifert, Burkhardt [4 ]
Werner, Clement M. L. [1 ]
机构
[1] Univ Zurich, Div Trauma Surg, Dept Surg, Univ Zurich Hosp, CH-8091 Zurich, Switzerland
[2] Kantonsspital Baden, Clin Orthopaed & Trauma Surg, Baden, Switzerland
[3] Univ Childrens Hosp Zurich, Orthopaed Div, Dept Surg, Zurich, Switzerland
[4] Univ Zurich, Dept Biostat, Epidemiol Biostat & Prevent Inst, Zurich, Switzerland
关键词
Radiation protection; X-ray; Compliance; Knowledge; Operating room personnel; Trauma surgery; Questionnaire; Training; INTRAOPERATIVE SCATTERED RADIATION; IONIZING-RADIATION; TRAUMA SURGEONS; EXPOSURE; FLUOROSCOPY; RISK; HIP; SIMULATION; FIXATION; HAND;
D O I
10.1007/s00402-015-2257-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Radiation protection is becoming more important with an ongoing increase in radiation exposure due to the use of X-rays in minimally invasive procedures in orthopaedic and trauma surgeries. However, sufficient education in medical physics and radiation protection can often be improved. A questionnaire consisting of four questions about personal data and ten questions about radiation protection was distributed to lead consultants, consultants, residents, medical students, and medical technical assistants at two institutions, a level 1 trauma center and a children's hospital. This study consisted of 83 participants. The compliance with radiation protection, i.e., usage of a dosimetry, an apron, and a thyroid shield on a regular basis was only seen in 54 %. Participants from the trauma center wore a dosimeter and thyroid shield significantly more often. The regular use of a thyroid shield differed significantly between job positions. It was observed in 80 % of students, but only 15 % of technical assistants. Only 65 % of all knowledge questions were answered correctly. There was a discrepancy between incorrectly answered knowledge questions (35 %) and those marked as uncertain (20 %). Different job positions did not have an impact on the answers to the questions in most instances. The compliance with and the knowledge about radiation protection seems to be unnecessarily low in trauma physicians and technical assistants. The discrepancy in falsely answered questions and those marked as uncertain may suggest that participants may overestimate their knowledge about radiation protection, which is potentially harmful due to the increased radiation exposure. Therefore, we advocate a quick and valuable training of trauma surgeons and medical staff addressing the important preventive measures, some of which are illustrated in the present study. These consist of wearing dosimetry and protection devices, reduction in X-ray duration, preferably antero-posterior C-arm positioning with the image intensifier close to the patient and the surgeon, maximal distance, collimation, and increased voltage. Furthermore, the use of visual feedback on complex and potentially hazardous radiation facts may be useful for training purposes. Cross-sectional study with a questionnaire.
引用
收藏
页码:1233 / 1240
页数:8
相关论文
共 40 条
[1]   Scattered radiation during fixation of hip fractures - Is distance alone enough protection? [J].
Alonso, JA ;
Shaw, DL ;
Maxwell, A ;
McGill, GP ;
Hart, GC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :815-818
[2]  
[Anonymous], ION RAD OCC RAD PROT
[3]  
[Anonymous], 2007, ANN ICRP, V37, P2
[4]  
[Anonymous], OPERATIVE ORTHOPADIE
[5]  
[Anonymous], BUND KONS GES RECHTS
[6]   THE RISK FROM RADIATION EXPOSURE DURING OPERATIVE X-RAY SCREENING IN HAND SURGERY [J].
ARNSTEIN, PM ;
RICHARDS, AM ;
PUTNEY, R .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1994, 19B (03) :393-396
[7]   Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience [J].
Botchu, Rajesh ;
Ravikumar, Kassetti .
INDIAN JOURNAL OF ORTHOPAEDICS, 2008, 42 (04) :471-473
[8]  
Bott OJ, 2011, RADIOGRAPHICS, V31, pE31, DOI [10.1148/rg.313105125, 10.1148/rg.313105125/-/DC1]
[9]   Improving education on C-arm operation and radiation protection with a computer-based training and simulation system [J].
Bott, Oliver Johannes ;
Wagner, Markus ;
Duwenkamp, Christopher ;
Hellrung, Nils ;
Dresing, Klaus .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (04) :399-407
[10]  
Burns S, 2013, J BONE JOINT SURG AM, V95A, P1307, DOI [10.2106/JBJS.L.00893, 10.2106/JBJS.L00893]