Internal Lefort III and monobloc distraction with biodegradable devices

被引:0
作者
Cohen, SR [1 ]
Holmes, RE [1 ]
机构
[1] Childrens Hosp & Hlth Care Ctr San Diego, Craniofacial Surg Serv, San Diego, CA USA
来源
3RD INTERNATIONAL CONGRESS ON CRANIAL AND FACIAL BONE DISTRACTION PROCESSES: 2001 DISTRACTION ODYSSEY | 2001年
关键词
midface hypoplasia; distraction osteogenesis; resorbable fixation; LeFort III advancement; monobloc advancement;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In spite of the many advantages of internal metallic distraction devices, they can be more difficult to remove. By substituting the metallic fixation plates of the Stryker-Leibinger Modular Internal Distraction system, with resorbable MacroPore fixation mesh, only the distractor screw and cable drive need to be removed. Moreover, by utilizing a resorbable stabilizer, the screw and cable components are not needed for the consolidation phase, and can be removed at the completion of active distraction. Herein, 33 patients undergoing internal craniofacial distraction are presented. The MID system was utilized in 21, while a new Macropore, biodegradable distractor was employed in 12. The report documents our results and demonstrates early success with a new type of bioresorbable device. Our initial concept was to link plates and screws to a buried driving device. [1] This, in theory, would permit easy adaptation to almost all anatomic sites and variants. Toward this coal, we worked with Leibinger ultimately developing the Modular Internal Distraction (MID) system (Stryker-Leibinger, Inc., Kalamazoo, MI). [2] The MID system allowed the surgeon to fabricate custom internal distraction devices for virtually any region of the craniofacial skeleton. The first generation system contains expansion screws capable of 15 mm and 30 mm. of distraction. Depending on the distraction site and osteotomy, any configuration of titanium plates could be attached to the distraction screw to permit uniplanar internal distraction. A flexible activation cable is brought out through a distant, inconspicuous stab wound in the hair behind the ear. The MID system has been used extensively. It's primary disadvantage has been the difficulty of removal. We prefer to remove all hardware whenever feasible. Thus, a second operation, which required similar exposure to the first was required for device explantation. To eliminate the difficulty of device removal, we worked with the development team at MacroPore, Inc. (San Diego, CA) to come up with a resorbable design. On November 19, 1999, the first resorbable distractor was employed in a 13 year old boy with hemifacial microsomia to correct severe malar hypoplasia. [3] The device worked well and was easy to remove. Furthermore, because of the development of a new biodegradable stabilization plate, the metallic driving device could be explanted at the conclusion of the distraction period. This permitted rapid and early device removal without the need for complete re-exposure. The biodegradable stabilization plate provided rigid fixation of the advancement, while protecting the underlying, immature bony regenerate. Consolidation was therefore allowed to take place, while eliminating the external cable and the attached metallic distraction screw.
引用
收藏
页码:447 / 454
页数:8
相关论文
共 50 条
  • [41] Double-step transport distraction osteogenesis in the reconstruction of unilateral large mandibular defects after tumour resection using internal distraction devices
    Wang, J. J.
    Chen, J.
    Ping, F. Y.
    Yan, F. G.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (05) : 587 - 595
  • [42] Comparison of Lefort-1 advancement by internal and external distraction osteogenesis in non-syndromic cleft lip and palate: A systematic review and meta-analysis
    Pandey, Sameer
    Chug, Ashi
    Reddy, Srinivas Gosla
    Simre, Saurabh S.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2025, 37 (01) : 23 - 30
  • [43] Frontofacial advancement by internal distraction devices. A technical modification for the management of craniofacial dysostosis in early childhood
    Adolphs, N.
    Klein, M.
    Haberl, E. -J.
    Menneking, H.
    Hoffmeister, B.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (06) : 777 - 782
  • [44] Additional orthognathic surgery following Le Fort III and monobloc advancement
    Nout, E.
    Koudstaal, M. J.
    Wolvius, E. B.
    Van der Wal, K. G. H.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (07) : 679 - 684
  • [45] Simultaneous Lefort 2 Distraction and Fronto-Orbito-Malar Advancement: Correcting Severe Upper and Midface Retrusion in a Patient With Crouzon Syndrome
    De Stefano, Sofia
    Lopez, Emmanuela Nadal
    Sabas, Mariana
    JOURNAL OF CRANIOFACIAL SURGERY, 2025, 36 (02) : e209 - e211
  • [46] Modified Lefort Distraction Osteogenesis for the Treatment of Nager Syndrome-Associated Midface Hypoplasia: Technique and Review
    Simpson, Andrew M.
    Mehta, Sagar T.
    Siddiqi, Faizi
    Yamashiro, Duane
    Gociman, Barbu
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (06) : E621 - E623
  • [47] Soft-Tissue Volumetric Changes Following Monobloc Distraction Procedure: Analysis Using Digital Three-Dimensional Photogrammetry System (3dMD)
    Chan, Fuan Chiang
    Kawamoto, Henry K.
    Federico, Christina
    Bradley, James P.
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (02) : 416 - 420
  • [48] Midface correction in patients with Crouzon syndrome is Le Fort III distraction osteogenesis with a rigid external distraction device the gold standard?
    Engel, Michael
    Berger, Moritz
    Hoffmann, Juergen
    Kuehle, Reinald
    Rueckschloss, Thomas
    Ristow, Oliver
    Freudlsperger, Christian
    Kansy, Katinka
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (03) : 420 - 430
  • [49] Rapid maxillary distraction protocol utilizing the halo distraction system and rigid internal fixation
    Baker, Stephen B.
    Reid, Russell R.
    Burkey, Brooke
    Bartlett, Scott P.
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2007, 44 (05) : 476 - 481
  • [50] Fronto-facial monobloc distraction in syndromic craniosynostosis. Three-dimensional evaluation of treatment outcome and facial growth
    Ko, E. W-C.
    Chen, P. K-T.
    Tai, I. C-H.
    Huang, C. S.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (01) : 20 - 27