Automated synthesis of hypoxia imaging agent [18F]FMISO based upon a modified Explora FDG4 module

被引:14
|
作者
Wang, Mingwei [1 ]
Zhang, Yingjian [1 ]
Zhang, Yongping [1 ]
Yuan, Huiyu [1 ]
机构
[1] Fudan Univ, PET Ctr, Dept Nucl Med, Dept Oncol,Shanghai Med Coll, Shanghai 200032, Peoples R China
基金
中国国家自然科学基金;
关键词
NECK-CANCER; FLUOROMISONIDAZOLE; HEAD; PET;
D O I
10.1007/s10967-008-7395-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new automated synthesis procedure of 1-H-1-(3-[F-18]fluoro-2-hydroxypropyl)-2-nitroimidazole ([F-18]FMISO), a specific hypoxia imaging agent with great significances for the noninvasive, dynamic hypoxia evaluation of cancer, was developed by modifying Explora FDG(4) module, a commercial [F-18]FDG production system, in this study. Its radiochemical synthesis was carried out via two sequent reaction steps, i.e. the nucleophilic displacement of labeling precursor 1-(2'-nitro-1'-imidazolyl)-2-O-tetrahydropyranyl-3-O-tosyl-propanediol (NITTP) with activated F-18- ion at 100 A degrees C for 8 minutes, and the following hydrolysis with 1M HCl at 100 A degrees C for 5 minutes and neutralization with 1M NaOH. Two-pot reaction with two independent separations was adopted to assure the good separation of final product via solid phase extraction (SPE) based upon combined Sep-pak cartridges instead of high performance liquid chromatography (HPLC). This fast, reliable preparation route of F-18-FMISO could complete within 50 minutes with about 55% of high radiochemical yield (with decay correction) and more than 98% of good radiochemical purity. The modified module could perform multiple runs of production of [F-18]FMISO.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [1] Automated Synthesis of 18F-Fluoroacetate Using Explora FDG4 Module
    Sun, Li-Quan
    Luo, Ai-Qin
    Fujibayashi, Yasuhisa
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2315 - +
  • [2] Fully Automated Methods for [18F]FDG and [18F]-NaF Productions Using Explora FDG4: Validation and Reliability of Multi-subsequent Preparations for Clinical Applications
    Awad, Eman
    Ali, Hatim
    Lamb, James
    Al-Momani, Ehab
    CURRENT RADIOPHARMACEUTICALS, 2022, 15 (04) : 341 - 346
  • [3] Automated synthesis of [18F]FMISO on IBA Synthera®
    Blom, Elisabeth
    Koziorowski, Jacek
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 299 (01) : 265 - 270
  • [4] Comparison of [18F]-FMISO, [18F]-FAZA and [18F]-HX4 for PET imaging of hypoxia - a simulation study
    Wack, Linda J.
    Moennich, David
    Van Elmpt, Wouter
    Zegers, Catharina M. L.
    Troost, Esther G. C.
    Zips, Daniel
    Thorwarth, Daniela
    ACTA ONCOLOGICA, 2015, 54 (09) : 1370 - 1377
  • [5] Comparison of three 18F-labeled 2-nitroimidazoles for imaging hypoxia in breast cancer xenografts: [18F]FBNA, [18F]FAZA and [18F]FMISO
    dos Santos, Sofia Nascimento
    Wuest, Melinda
    Jans, Hans-Sonke
    Woodfield, Jenilee
    Nario, Arian Perez
    Krys, Daniel
    Dufour, Jennifer
    Glubrecht, Darryl
    Bergman, Cody
    Bernardes, Emerson Soares
    Wuest, Frank
    NUCLEAR MEDICINE AND BIOLOGY, 2023, 124
  • [6] First Comparison between [18f]-FMISO and [18f]-Faza for Preoperative Pet Imaging of Hypoxia in Lung Cancer
    Thureau, Sebastien
    Piton, Nicolas
    Gouel, Pierrick
    Modzelewski, Romain
    Dujon, Antoine
    Baste, Jean-Marc
    Melki, Jean
    Rinieri, Philippe
    Peillon, Christophe
    Rastelli, Olivier
    Lequesne, Justine
    Hapdey, Sebastien
    Sabourin, Jean-Christophe
    Bohn, Pierre
    Vera, Pierre
    CANCERS, 2021, 13 (16)
  • [7] Automated synthesis of [18F]FMISO on IBA Synthera®
    Elisabeth Blom
    Jacek Koziorowski
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 299 : 265 - 270
  • [8] Automated synthesis and PET evaluation of both enantiomers of [18F]FMISO
    Revunov, Evgeny
    Jorgensen, Jesper T.
    Jensen, Andreas Ingemann
    Hansen, Anders E.
    Severin, Gregory W.
    Kjaer, Andreas
    Zhuravlev, Fedor
    NUCLEAR MEDICINE AND BIOLOGY, 2015, 42 (04) : 413 - 419
  • [9] [18F]EF3 is not superior to [18F]FMISO for PET-based hypoxia evaluation as measured in a rat rhabdomyosarcoma tumour model
    Dubois, Ludwig
    Landuyt, Willy
    Cloetens, Lieselotte
    Bol, Anne
    Bormans, Guy
    Haustermans, Karin
    Labar, Daniel
    Nuyts, Johan
    Gregoire, Vincent
    Mortelmans, Luc
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (02) : 209 - 218
  • [10] High-yield automated synthesis of [18F]fluoroazomycin arabinoside ([18F]FAZA) for hypoxia-specific tumor imaging
    Hayashi, Kazutaka
    Furutsuka, Kenji
    Takei, Makot
    Muto, Masatoshi
    Nakao, Ryuji
    Aki, Hatsumi
    Suzuki, Kazutoshi
    Fukumura, Toshimitsu
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (07) : 1007 - 1013