共 50 条
Auditory cortex activation in deaf subjects during cochlear electrical stimulation - Evaluation by functional magnetic resonance imaging
被引:24
作者:
Berthezene, Y
Truy, E
Morgon, A
Giard, MH
Hermier, M
Franconi, JM
Froment, JC
机构:
[1] HOP EDOUARD HERRIOT,DEPT OTORHINOLARYNGOL,LYON,FRANCE
[2] CNRS,UPRESSA 5020,LYON,FRANCE
[3] INSERM,U280,F-69008 LYON,FRANCE
[4] SIEMENS,PARIS,FRANCE
关键词:
functional magnetic resonance imaging;
auditory cortex;
electrical cochlear stimulation;
deafness;
cochlear implant candidates;
D O I:
10.1097/00004424-199705000-00007
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
RATIONALE AND OBJECTIVES. The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS. Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven cochlear implant candidates. These patients suffered from postlingual-acquired deafness. Four patients were stimulated above the electrical perception threshold and three below the electrical discomfort threshold. Functional scans (fast low-angle shot 91 mseconds/60 mseconds) were acquired in an oblique axial plane running parallel to the sylvian fissure. Pour consecutive series of six images were obtained in 6 minutes. The acquisition time of each image was 15 seconds. RESULTS. During electrical cochlear stimulation below the discomfort threshold, the three patients described ''auditory'' sensations with activation of the superior temporal regions. In two patients with electrical stimulation of the left ear, the maximum signal intensity increased by 8.42% in the right auditory cortex and 5.69% in the left. In one patient with a right electrical stimulation only the left cortex was activated. Electrical cochlear stimulation above the perception threshold induces no significant activation in the auditory cortex. CONCLUSION. Functioning MR imaging can detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using a conventional 1.5-tesla system in a routine hospital environment. Further studies are needed to investigate its usefulness in clinical practice.
引用
收藏
页码:297 / 301
页数:5
相关论文