Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources

被引:3
|
作者
Meigooni, Ali S. [1 ,2 ]
Luerman, Christine M. [2 ]
Sowards, Keith T. [3 ]
机构
[1] N Shore Univ Hosp, Dept Radiat Med, Manhasset, NY 11030 USA
[2] Univ Kentucky, Dept Radiat Med, Med Ctr, Lexington, KY 40536 USA
[3] Univ Louisville, James Graham Brown Canc Ctr, Louisville, KY 40202 USA
关键词
biological organs; brachytherapy; dosimetry; iodine; palladium; INTERSTITIAL BRACHYTHERAPY SOURCES; MONTE-CARLO CALCULATIONS; DOSIMETRIC CHARACTERISTICS; RATE CONSTANT; THERMOLUMINESCENT DOSIMETRY; TRANSVERSE-AXIS; AIDED DOSIMETRY; ANISOTROPY FUNCTIONS; SOLID PHANTOMS; MODEL; 6711;
D O I
10.1118/1.3095776
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, several different models of I-125 and Pd-103 brachytherapy sources have been introduced in order to meet the increasing demand for prostate seed implants. These sources have different internal structures; hence, their TG-43 dosimetric parameters are not the same. In this study, the effects of the dosimetric differences among the sources on their clinical applications were evaluated. The quantitative and qualitative evaluations were performed by comparisons of dose distributions and dose volume histograms of prostate implants calculated for various designs of I-125 and Pd-103 sources. These comparisons were made for an identical implant scheme with the same number of seeds for each source. The results were compared with the Amersham model 6711 seed for I-125 and the Theragenics model 200 seed for Pd-103 using the same implant scheme.
引用
收藏
页码:1452 / 1458
页数:7
相关论文
共 50 条
  • [41] Permanent implantation of 125I sources in the prostate:: Radical limits of simplicity
    McLaughlin, PW
    Narayana, V
    Fields, MT
    Dworzanin, ME
    Winfield, RJ
    Roberson, PL
    RADIOLOGY, 1999, 213 (03) : 839 - 844
  • [42] Investigation of dose distribution of TheraSeed 200 103Pd brachytherapy seed on coaxial cylindrical phantom shells using Monte Carlo simulation
    Camgoz, Berkay
    Kumru, Mehmet Nurullah
    ANNALS OF NUCLEAR MEDICINE, 2011, 25 (05) : 371 - 379
  • [43] DICOM CT-based Monte Carlo dose calculations for prostate permanent implant using 125I seed sources
    Mishra, Subhalaxmi
    Deshpande, Sudesh
    Pathan, Munir S.
    Selvam, T. Palani
    RADIATION PHYSICS AND CHEMISTRY, 2023, 210
  • [44] A 17-year retrospective study of institutional results for eye plaque brachytherapy of uveal melanoma using 125I, 103Pd, and 131Cs and historical perspective
    Leonard, Kara L.
    Gagne, Nolan L.
    Mignano, John E.
    Duker, Jay S.
    Bannon, Elizabeth A.
    Rivard, Mark J.
    BRACHYTHERAPY, 2011, 10 (04) : 331 - 339
  • [45] A new genetic algorithm technique in optimization of permanent 125I prostate implants
    Yang, GZ
    Reinstein, LE
    Pai, S
    Xu, ZG
    Carroll, DL
    MEDICAL PHYSICS, 1998, 25 (12) : 2308 - 2315
  • [46] Dosimetric comparison of four new design 103Pd brachytherapy sources: Optimal design using silver and copper rod cores
    Hosseini, S. Hamed
    Sadeghi, Mahdi
    Ataeinia, Vahideh
    MEDICAL PHYSICS, 2009, 36 (07) : 3080 - 3085
  • [47] SOME TREATMENT PLANNING CONSIDERATIONS FOR PD-103 AND I-125 PERMANENT INTERSTITIAL IMPLANTS
    NATH, R
    MEIGOONI, AS
    MELILLO, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (05): : 1131 - 1138
  • [48] Monte Carlo radiation dose simulations and dosimetric comparison of the model 6711 and 9011 125I brachytherapy sources
    Rivard, Mark J.
    MEDICAL PHYSICS, 2009, 36 (02) : 486 - 491
  • [49] Monte Carlo modeling of the transverse-axis dose distribution of the Model 200 103Pd interstitial brachytherapy source
    Williamson, JF
    MEDICAL PHYSICS, 2000, 27 (04) : 643 - 654
  • [50] A dose-response study for I-125 prostate implants
    Stock, RG
    Stone, NN
    Tabert, A
    Iannuzzi, C
    DeWyngaert, JK
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (01): : 101 - 108