Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources

被引:3
|
作者
Meigooni, Ali S. [1 ,2 ]
Luerman, Christine M. [2 ]
Sowards, Keith T. [3 ]
机构
[1] N Shore Univ Hosp, Dept Radiat Med, Manhasset, NY 11030 USA
[2] Univ Kentucky, Dept Radiat Med, Med Ctr, Lexington, KY 40536 USA
[3] Univ Louisville, James Graham Brown Canc Ctr, Louisville, KY 40202 USA
关键词
biological organs; brachytherapy; dosimetry; iodine; palladium; INTERSTITIAL BRACHYTHERAPY SOURCES; MONTE-CARLO CALCULATIONS; DOSIMETRIC CHARACTERISTICS; RATE CONSTANT; THERMOLUMINESCENT DOSIMETRY; TRANSVERSE-AXIS; AIDED DOSIMETRY; ANISOTROPY FUNCTIONS; SOLID PHANTOMS; MODEL; 6711;
D O I
10.1118/1.3095776
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, several different models of I-125 and Pd-103 brachytherapy sources have been introduced in order to meet the increasing demand for prostate seed implants. These sources have different internal structures; hence, their TG-43 dosimetric parameters are not the same. In this study, the effects of the dosimetric differences among the sources on their clinical applications were evaluated. The quantitative and qualitative evaluations were performed by comparisons of dose distributions and dose volume histograms of prostate implants calculated for various designs of I-125 and Pd-103 sources. These comparisons were made for an identical implant scheme with the same number of seeds for each source. The results were compared with the Amersham model 6711 seed for I-125 and the Theragenics model 200 seed for Pd-103 using the same implant scheme.
引用
收藏
页码:1452 / 1458
页数:7
相关论文
共 50 条
  • [31] Dosimetric comparison between realistic ocular model and other models for COMS plaque brachytherapy with 103Pd, 131Cs, and 125I radioisotopes
    Ebrahimi-Khankook, Atiyeh
    Vejdani-Noghreiyan, Alireza
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2018, 57 (03) : 265 - 275
  • [32] Cluster pattern analysis of energy deposition sites for the brachytherapy sources 103Pd, 125I, 192Ir, 137Cs, and 60Co
    Villegas, Fernanda
    Tilly, Nina
    Backstrom, Gloria
    Ahnesjo, Anders
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18) : 5531 - 5543
  • [33] Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for 125I prostate implants
    Assam, Isong
    Vijande, Javier
    Ballester, Facundo
    Perez-Calatayud, Jose
    Poppe, Bjorn
    Siebert, Frank-Andre
    MEDICAL PHYSICS, 2022, 49 (09) : 6195 - 6208
  • [34] Idealized line source configuration for permanent 125I prostate implants
    Leclerc, G
    Lavallée, MC
    Tubic, D
    Métivier, J
    Vigneault, É
    Beaulieu, L
    RADIOTHERAPY AND ONCOLOGY, 2004, 72 (02) : 213 - 220
  • [35] Evolution of dose distribution for a 125I eye plaque using MCNPX and Plaque Simulator software
    Poorbaygi, Hosein
    Sardari, Elham
    Aghamiri, Seyed Mahmoud Reza
    Sheibani, Shahab
    Arjmand, Mojtaba
    Moradi, Somayeh
    Ghassemi, Fariba
    PRECISION RADIATION ONCOLOGY, 2024, 8 (02): : 70 - 76
  • [36] Treatment-planning considerations for prostate implants with the new linear RadioCoil™ 103Pd brachytherapy source
    Meigooni, Ali S.
    Awan, Shahid B.
    Rachabatthula, Venkata
    Koona, Rafiq A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (03): : 23 - 36
  • [37] A comparison of the impact of isotope (125I vs. 103Pd) on toxicity and biochemical outcome after interstitial brachytherapy and external beam radiation therapy for clinically localized prostate cancer
    Kollmeier, Marisa A.
    Pei, Xin
    Algur, Ece
    Yamada, Yoshiya
    Cox, Brett W.
    Cohen, Gil'ad N.
    Zaider, Marco
    Zelefsky, Michael J.
    BRACHYTHERAPY, 2012, 11 (04) : 271 - 276
  • [38] Evaluation of the Dosimetric Parameters for 125I Brachytherapy Determined in Prostate Medium using CT Images
    Hanada, Takashi
    Yorozu, Atsunori
    Ohashi, Toshio
    Shigematsu, Naoyuki
    Maruyama, Koichi
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (05) : 553 - 561
  • [39] Evaluation of dose enhancement in presence of gold nanoparticles in eye brachytherapy by 103Pd source
    Rezaei, Hadi
    Zabihzadeh, Mansour
    Ghorbani, Mahdi
    Ahmadabad, Foad Goli
    Mostaghimi, Hesameddin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (03) : 545 - 553
  • [40] Is there a preferred strength for regularly spaced 125I seeds in inverse-planned prostate implants?
    Sloboda, RS
    Pedersen, JE
    Halperin, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (01): : 234 - 244