Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources

被引:3
|
作者
Meigooni, Ali S. [1 ,2 ]
Luerman, Christine M. [2 ]
Sowards, Keith T. [3 ]
机构
[1] N Shore Univ Hosp, Dept Radiat Med, Manhasset, NY 11030 USA
[2] Univ Kentucky, Dept Radiat Med, Med Ctr, Lexington, KY 40536 USA
[3] Univ Louisville, James Graham Brown Canc Ctr, Louisville, KY 40202 USA
关键词
biological organs; brachytherapy; dosimetry; iodine; palladium; INTERSTITIAL BRACHYTHERAPY SOURCES; MONTE-CARLO CALCULATIONS; DOSIMETRIC CHARACTERISTICS; RATE CONSTANT; THERMOLUMINESCENT DOSIMETRY; TRANSVERSE-AXIS; AIDED DOSIMETRY; ANISOTROPY FUNCTIONS; SOLID PHANTOMS; MODEL; 6711;
D O I
10.1118/1.3095776
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, several different models of I-125 and Pd-103 brachytherapy sources have been introduced in order to meet the increasing demand for prostate seed implants. These sources have different internal structures; hence, their TG-43 dosimetric parameters are not the same. In this study, the effects of the dosimetric differences among the sources on their clinical applications were evaluated. The quantitative and qualitative evaluations were performed by comparisons of dose distributions and dose volume histograms of prostate implants calculated for various designs of I-125 and Pd-103 sources. These comparisons were made for an identical implant scheme with the same number of seeds for each source. The results were compared with the Amersham model 6711 seed for I-125 and the Theragenics model 200 seed for Pd-103 using the same implant scheme.
引用
收藏
页码:1452 / 1458
页数:7
相关论文
共 50 条
  • [21] Optic Disc Dose Comparison Between 125I and 103Pd Collaborative Ocular Melanoma Study (COMS) Plaques Based on Current Clinical Practice
    Lee, Yongsook C.
    Lin, Shih-Chi
    Kim, Yongbok
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (06)
  • [22] The impact of prescription depth, dose rate, plaque size, and source loading on the central axis using 103Pd, 125I, and 131Cs
    Rivard, Mark J.
    Melhus, Christopher S.
    Sioshansi, Shirin
    Morr, Jody
    BRACHYTHERAPY, 2008, 7 (04) : 327 - 335
  • [23] RADIATION DOSE DELIVERED BY 125I, 103PD AND 131CS AND DOSE ENHANCEMENT BY GOLD NANOPARTICLE (GNP) SOLUTION IN PROSTATE BRACHYTHERAPY: A COMPARATIVE ANALYSIS BY MONTE CARLO SIMULATION
    Khan, Hamda
    Aziz, Umair
    Koreshi, Zafar Ullah
    IIUM ENGINEERING JOURNAL, 2019, 20 (02): : 176 - 187
  • [24] Dose optimization in 125I permanent prostate seed implants using the Monte Carlo method
    Reis, Juraci P.
    Menezes, Artur F.
    Souza, Edmilson M.
    Facure, Alessandro
    Medeiros, Jose A. C. C.
    Silva, Ademir X.
    COMPUTER PHYSICS COMMUNICATIONS, 2012, 183 (04) : 847 - 852
  • [25] Dosimetric analysis of urinary morbidity following prostate brachytherapy (125I vs. 103Pd) combined with external beam radiation therapy
    Chen, CT
    Waterman, FM
    Valicenti, RK
    Gomella, LG
    Strup, SE
    Dicker, AP
    INTERNATIONAL JOURNAL OF CANCER, 2001, 96 : 83 - 88
  • [26] 125I versus 103Pd for low-risk prostate cancer:: Preliminary PSA outcomes from a prospective randomized multicenter trial
    Wallner, K
    Merrick, G
    True, L
    Sutlief, S
    Cavanagh, W
    Butler, W
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (05): : 1297 - 1303
  • [27] Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co
    Reed, J. L.
    Rasmussen, B. E.
    Davis, S. D.
    Micka, J. A.
    Culberson, W. S.
    DeWerd, L. A.
    MEDICAL PHYSICS, 2014, 41 (12)
  • [28] High-resolution 3D dose distribution measured for two low-energy x-ray brachytherapy seeds: 125I and 103Pd
    Massillon-Jl, G.
    Minniti, R.
    Mitch, M. G.
    Soares, C. G.
    Hearn, R. A.
    RADIATION MEASUREMENTS, 2011, 46 (02) : 238 - 243
  • [29] Consequences of dose heterogeneity on the biological efficiency of 103Pd permanent breast seed implants
    Afsharpour, Hossein
    Reniers, Brigitte
    Landry, Guillaume
    Pignol, Jean-Philippe
    Keller, Brian M.
    Verhaegen, Frank
    Beaulieu, Luc
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03) : 809 - 823
  • [30] Dosimetric comparison between realistic ocular model and other models for COMS plaque brachytherapy with 103Pd, 131Cs, and 125I radioisotopes
    Atiyeh Ebrahimi-Khankook
    Alireza Vejdani-Noghreiyan