10-Year Follow-Up of the NexGen CR Total Knee Prosthesis

被引:6
|
作者
Hack, J. [1 ,2 ]
Mai, S. [1 ]
Siebert, W. [1 ]
机构
[1] Klin Kassel, Vitos Orthopad, Kassel, Germany
[2] Univ Klinikum Giessen & Marburg GmbH, Klin Unfall Hand & Wiederherstellungschirurg, D-35043 Marburg, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE | 2015年 / 153卷 / 05期
关键词
total knee arthroplasty; NexGen (R) CR; 10-year survival rate; knee osteoarthritis; ARTHROPLASTY; SYSTEM; MINIMUM; SURVIVORSHIP; 14-YEAR; DESIGN; TKA;
D O I
10.1055/s-0035-1546040
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this study was to evaluate long-term clinical and radiological results as well as survival rates of the NexGen (R) CR posterior cruciate retaining prosthesis. Patients and Methods: We evaluated a consecutive series of 761 total knee replacements performed on 716 patients from 1999 to 2001 at our institution. All patients had been recorded prospectively in our in-house arthroplasty register. Follow-up data were available for 379 patients at 10 years postoperatively. Functional outcome was evaluated using the Knee Society score. An additional radiographic evaluation was performed on 224 patients at 10 years. The mean age of the patients at the time of surgery was 71 years. 75% of the patients were female, 25% were male. Mean BMI of the patients was 29.2 kg/m(2). The preoperative diagnosis was osteoarthritis in 91%, rheumatoid arthritis in 5,5% and posttraumatic osteoarthritis in 2%. Patella resurfacing was performed in 4%. All components were cemented. Results and Discussion: Mean Knee Society clinical score improved from 26.7 points preoperatively to 88.5 points at the time of the latest follow-up, and mean Knee Society function score improved from 48.3 to 55.2 points. Flexion improved from a mean of 106.7 degrees preoperatively to 111.4 degrees at 10 years. Patellofemoral pain was indicated by 66% of the patients before surgery and 4% at the latest follow-up. 96% were satisfied with the result of the surgery at 10 years. Radiographic evaluation was performed on 224 patients at the time of the latest follow-up. 203 patients (91%) had normal radiographic findings, 21 patients (9%) showed pathological findings. Radiolucencies were seen in 18 patients on the AP view of the tibia, 1 patient had an additional femoral radiolucency. There was an osteolysis located in the lateral tibia seen in 1 patient and an occurrence of heterotopic ossification in another patient. One knee showed a patella subluxation. No patient had radiographic evidence of loosening. 17 knees had required revision surgery with exchange of at least one of the components up to 10 years after the index procedure. 5 of the patients had revision for a deep infection, 2 for periprosthetic fractures of the distal femur with loosening of the prosthesis, 1 for fracture of the proximal tibia due to osteoporosis, 4 for aseptic loosening, 3 for instability and 2 for severe pain. Kaplan-Meier survival of all components using revision for any reason as the end point was 97.8% at 10 years. Conclusion: The good clinical and radiological long-term results as well as the satisfactory survival rate after total knee replacement with the NexGen CR (R) prosthesis are comparable with the results of other long-term studies using the NexGen CR (R) and assimilable prosthesis. Our results demonstrate that quality of life was improved by the implantation of the NexGen CR (R) prosthesis even a long time after the index procedure despite old age and comorbidity of the patients.
引用
收藏
页码:508 / 515
页数:8
相关论文
共 50 条
  • [31] Is Immediate Postoperative Mechanical Axis Associated with the Revision Rate of Primary Total Knee Arthroplasty? A 10-Year Follow-up Study
    Park, Ju-Kwon
    Seon, Jong-Keun
    Cho, Kyu-Jin
    Lee, Nam-Hoon
    Song, Eun-Kyoo
    CLINICS IN ORTHOPEDIC SURGERY, 2018, 10 (02) : 167 - 173
  • [32] Early experience with the NexGen((R)) CR-Flex Mobile knee arthroplasty system: results of 2-year follow-up
    Endres, Stefan
    Wilke, Axel
    ORTHOPEDIC REVIEWS, 2010, 2 (01) : 3 - 5
  • [33] Good results with minimally invasive unicompartmental knee resurfacing after 10-year follow-up
    Redish M.H.
    Fennema P.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (5) : 959 - 965
  • [34] The Survivorship and Clinical Results of Minimally Invasive Unicompartmental Knee Arthroplasty at 10-Year Follow-up
    Kim, Kyung Tae
    Lee, Song
    Kim, Jee Hyoung
    Hong, Sung Won
    Jung, Woo Shik
    Shin, Won Shik
    CLINICS IN ORTHOPEDIC SURGERY, 2015, 7 (02) : 199 - 206
  • [35] Long-term outcomes of total elbow arthroplasty: a systematic review of studies at 10-year follow-up
    Davey, Martin S.
    Hurley, Eoghan T.
    Gaafar, Mohamed
    Molony, Diarmuid
    Mullett, Hannan
    Pauzenberger, Leo
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (06) : 1423 - 1430
  • [36] Does computer-assisted surgery influence survivorship of cementless total knee arthroplasty in patients with primary osteoarthritis? A 10-year follow-up study
    Hervé Ouanezar
    Florent Franck
    Alexandre Jacquel
    Vincent Pibarot
    Julien Wegrzyn
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3448 - 3456
  • [37] A 15 to 17-year follow-up of the Kinemax total knee replacement
    Grazette, Andrew J.
    Wylde, Vikki
    Dixon, Samantha
    Whitehouse, Sarah L.
    Blom, Ashley W.
    Whitehouse, Michael R.
    KNEE, 2018, 25 (06) : 1292 - 1298
  • [38] Ivory arthroplasty for trapeziometacarpal osteoarthritis: 10-year follow-up
    Vissers, Gino
    Goorens, Chul Ki
    Vanmierlo, Bert
    Bonte, Francis
    Mermuys, Koen
    Fils, Jean-Francois
    Goubau, Jean F.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2019, 44 (02) : 138 - 145
  • [39] Prospective, Randomized Study Between Insall-Burstein II and NexGen Legacy with a Minimum 9-Year Follow-Up
    Oh, Kwang-Jun
    Goodman, Stuart B.
    Yang, Jae-Hyuk
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1232 - 1238
  • [40] Long-term clinical results of alumina ceramic medial pivot total knee arthroplasty: a 10-year follow-up study
    Hideki Ueyama
    Shigeru Nakagawa
    Yuichi Kishimura
    Yukihide Minoda
    Suguru Nakamura
    Junichiro Koyanagi
    Mitsuyoshi Yamamura
    Yoshinori Kadoya
    Arthroplasty, 5