10-Year Follow-Up of the NexGen CR Total Knee Prosthesis

被引:6
|
作者
Hack, J. [1 ,2 ]
Mai, S. [1 ]
Siebert, W. [1 ]
机构
[1] Klin Kassel, Vitos Orthopad, Kassel, Germany
[2] Univ Klinikum Giessen & Marburg GmbH, Klin Unfall Hand & Wiederherstellungschirurg, D-35043 Marburg, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE | 2015年 / 153卷 / 05期
关键词
total knee arthroplasty; NexGen (R) CR; 10-year survival rate; knee osteoarthritis; ARTHROPLASTY; SYSTEM; MINIMUM; SURVIVORSHIP; 14-YEAR; DESIGN; TKA;
D O I
10.1055/s-0035-1546040
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this study was to evaluate long-term clinical and radiological results as well as survival rates of the NexGen (R) CR posterior cruciate retaining prosthesis. Patients and Methods: We evaluated a consecutive series of 761 total knee replacements performed on 716 patients from 1999 to 2001 at our institution. All patients had been recorded prospectively in our in-house arthroplasty register. Follow-up data were available for 379 patients at 10 years postoperatively. Functional outcome was evaluated using the Knee Society score. An additional radiographic evaluation was performed on 224 patients at 10 years. The mean age of the patients at the time of surgery was 71 years. 75% of the patients were female, 25% were male. Mean BMI of the patients was 29.2 kg/m(2). The preoperative diagnosis was osteoarthritis in 91%, rheumatoid arthritis in 5,5% and posttraumatic osteoarthritis in 2%. Patella resurfacing was performed in 4%. All components were cemented. Results and Discussion: Mean Knee Society clinical score improved from 26.7 points preoperatively to 88.5 points at the time of the latest follow-up, and mean Knee Society function score improved from 48.3 to 55.2 points. Flexion improved from a mean of 106.7 degrees preoperatively to 111.4 degrees at 10 years. Patellofemoral pain was indicated by 66% of the patients before surgery and 4% at the latest follow-up. 96% were satisfied with the result of the surgery at 10 years. Radiographic evaluation was performed on 224 patients at the time of the latest follow-up. 203 patients (91%) had normal radiographic findings, 21 patients (9%) showed pathological findings. Radiolucencies were seen in 18 patients on the AP view of the tibia, 1 patient had an additional femoral radiolucency. There was an osteolysis located in the lateral tibia seen in 1 patient and an occurrence of heterotopic ossification in another patient. One knee showed a patella subluxation. No patient had radiographic evidence of loosening. 17 knees had required revision surgery with exchange of at least one of the components up to 10 years after the index procedure. 5 of the patients had revision for a deep infection, 2 for periprosthetic fractures of the distal femur with loosening of the prosthesis, 1 for fracture of the proximal tibia due to osteoporosis, 4 for aseptic loosening, 3 for instability and 2 for severe pain. Kaplan-Meier survival of all components using revision for any reason as the end point was 97.8% at 10 years. Conclusion: The good clinical and radiological long-term results as well as the satisfactory survival rate after total knee replacement with the NexGen CR (R) prosthesis are comparable with the results of other long-term studies using the NexGen CR (R) and assimilable prosthesis. Our results demonstrate that quality of life was improved by the implantation of the NexGen CR (R) prosthesis even a long time after the index procedure despite old age and comorbidity of the patients.
引用
收藏
页码:508 / 515
页数:8
相关论文
共 50 条
  • [1] The Bi-Surface total knee arthroplasty: Minimum 10-year follow-up study
    Nakamura, Shinichiro
    Kobayashi, Masahiko
    Ito, Hiromu
    Nakamura, Kenji
    Ueo, Toyoji
    Nakamura, Takashi
    KNEE, 2010, 17 (04) : 274 - 278
  • [2] A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results
    Abonyi, Bence
    Pap, Karoly
    Gal, Tamas
    Vasarhelyi, Gabor
    Udvarhelyi, Ivan
    Hangody, Laszlo
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (01) : 10 - 16
  • [3] A high-flexion design total knee prosthesis: a ten to twelve-year follow-up study
    Kim, Man Soo
    Choi, Keun Young
    Hur, Jae Hyeong
    In, Yong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [4] Unicompartmental knee arthroplasty: 10-year follow-up
    Bistolfi, A.
    Crova, M.
    Deledda, D.
    Paonessa, M.
    Cimino, A.
    Ravera, L.
    Massazza, G.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2012, 63 (03) : 155 - 161
  • [5] The self-aligning knee prosthesis: clinical and radiological outcome and survival analysis of a cruciate retaining meniscal bearing knee at 10-year follow-up
    van Stralen, R. A.
    Anderson, P. G.
    Wymenga, A. B.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (11) : 2728 - 2734
  • [6] The EUROP total knee prosthesis: A ten-year follow-up study of a posterior cruciate-retaining design
    Mouttet, A.
    Louis, M. -L.
    Sourdet, V.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (06) : 639 - 647
  • [7] Cementless total knee arthroplasty with Profix: A 8-to 10-year follow-up study
    Hardeman, Francois
    Vandenneucker, Hilde
    Van Lauwe, Johan
    Bellemans, Johan
    KNEE, 2006, 13 (06) : 419 - 421
  • [8] Hybrid Component Fixation in Total Knee Arthroplasty Minimum of 10-Year Follow-Up Study
    Yang, Jae-Hyuk
    Yoon, Jung-Ro
    Oh, Chi-Hun
    Kim, Taik-Sun
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 1111 - 1118
  • [9] The Insall-Burstein total knee replacement in osteoarthritis - A 10-year minimum follow-up
    Aglietti, P
    Buzzi, R
    De Felice, R
    Giron, F
    JOURNAL OF ARTHROPLASTY, 1999, 14 (05) : 560 - 565
  • [10] LCS mobile-bearing total knee replacement. A 10-year's follow-up study
    Vogt, J. -C.
    Saarbach, C.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (03) : 177 - 182