Dispersion of indoor air pollutants emitted at near-floor levels in rooms with floor heating and mixing ventilation

被引:7
作者
Jurelionis, Andrius [1 ]
Stasiuliene, Laura [1 ]
Prasauskas, Tadas [2 ]
Martuzevicius, Dainius [2 ]
机构
[1] Kaunas Univ Technol, Dept Bldg Energy Syst, Studentu G 48, LT-51367 Kaunas, Lithuania
[2] Kaunas Univ Technol, Dept Environm Technol, Kaunas, Lithuania
关键词
Floor heating; Indoor air pollution; Personal exposure; Air distribution; CFD predictions; PERSONAL EXPOSURE; EMISSIONS; PARTICLES; CARPETS; VOC;
D O I
10.1177/1420326X16669975
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The usage of floor heating is increasing in low-energy buildings as it enables efficient applications of low-exergy level heat sources as well as provides a uniform distribution of air temperature and low air velocities in heated spaces. The aim of this study was to analyse the effects of floor heating on the dispersion of gaseous pollutants emitted at the floor level, considering that carpets and flooring materials can be sources of such pollution. Mixing ventilation with high-level wall grille air supply and in-ceiling four-way air supply was tested numerically and experimentally in the full-scale chamber at the air change rate of 2 h(-1). Three positions of a heated dummy in relation to the pollution source, cold surface and air supply diffusers were analysed. Both experiments and CFD predictions revealed the overall positive effect of floor heating on ventilation effectiveness and personal exposure. Floor heating increased pollutant removal effectiveness by 5% and reduced personal exposure by 22% on average.
引用
收藏
页码:205 / 218
页数:14
相关论文
共 31 条
  • [21] Human convective boundary layer and its interaction with room ventilation flow
    Licina, D.
    Melikov, A.
    Sekhar, C.
    Tham, K. W.
    [J]. INDOOR AIR, 2015, 25 (01) : 21 - 35
  • [22] Influence of geometry of thermal manikins on concentration distribution and personal exposure
    Melikov, A.
    Kaczmarczyk, J.
    [J]. INDOOR AIR, 2007, 17 (01) : 50 - 59
  • [23] Non-buoyant pollutant sources and particles in displacement ventilation
    Mundt, E
    [J]. BUILDING AND ENVIRONMENT, 2001, 36 (07) : 829 - 836
  • [24] Mundt M., 2004, Ventilation Effectiveness: Rehva Guidebooks
  • [25] Flow patterns and thermal comfort in a room with panel, floor and wall heating
    Myhren, Jonn Are
    Holmberg, Sture
    [J]. ENERGY AND BUILDINGS, 2008, 40 (04) : 524 - 536
  • [26] Nielsen P. V., 1992, INDOOR ENV TECHNOLOG, V98, P963
  • [27] Transport of particulate and gaseous pollutants in the vicinity of a human body
    Rim, Donghyun
    Novoselac, Atila
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (09) : 1840 - 1849
  • [28] Rydberg J, 1947, VVS, V3
  • [29] Material Emissions and Indoor Simulation
    Yu, Chuck W. F.
    Kim, Jeong Tai
    [J]. INDOOR AND BUILT ENVIRONMENT, 2013, 22 (01) : 21 - 29
  • [30] Building Pathology, Investigation of Sick Buildings - VOC Emissions
    Yu, Chuck Wah Francis
    Kim, Jeong Tai
    [J]. INDOOR AND BUILT ENVIRONMENT, 2010, 19 (01) : 30 - 39