Experimental study on refrigerant charge amount and optimal high pressure of a CO2 heat pump system for an electric bus

被引:0
|
作者
Guo, Yang [1 ]
Yang, Wei [2 ]
Wu, Haimei [2 ]
Li, Tao [2 ]
Chen, Shangmai [1 ]
Jin, Zunlong [1 ]
Deng, Rongbin [2 ]
机构
[1] Zhengzhou Univ, Sch Mech & Power Engn, Zhengzhou, Peoples R China
[2] Zhengzhou Kelin Motor Vehicle Air Conditioning Co, Zhengzhou, Peoples R China
关键词
AIR-CONDITIONING SYSTEM; CARBON-DIOXIDE; PERFORMANCE; R744; VEHICLE; SPACE;
D O I
10.1063/5.0117747
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to investigate the influence of refrigerant charge amount and discharge pressure on a CO2 heat pump system of an electric bus, an experiment setup was built. Tests were carried out in an enthalpy difference chamber to obtain the coefficient of performance and heating capacity of the system at each operating condition. The influence of operation parameters-including refrigerant charge amount, ambient temperature, outlet temperature of gas cooler, and compressor speed-was considered in this experiment. The results showed that the system performance was influenced by charge amount, and the minimum charge amount was 6.8 kg. The charge amount was almost independent of the ambient temperature, but the system performance was more sensitive to the charge amount at low temperatures. The optimal high-pressure relationship for this CO2 heat pump is p(opt) = 0.162T(gc.out) - 0.016T(amb) + 2.668, which was fitted considering both the outlet temperature of the gas cooler and the ambient temperature. Meanwhile, the low-temperature performance test (-22 & DEG;C) showed that this CO2 heat pump system can meet the operation requirements of city buses at low temperature.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] An experimental and theoretical investigation of refrigerant charge on a secondary loop air-conditioning heat pump system in electric vehicles
    Li, Kang
    Xu, Dan
    Lan, Jiao
    Su, Lin
    Fang, Yidong
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (08) : 3381 - 3398
  • [42] EXPERIMENTAL STUDY ON PERFORMANCE OF HEAT PUMP AIR CONDITIONING SYSTEM FOR PURE ELECTRIC BUS WITH ECONOMIZER
    Su, Zhiyong
    Li, Haijun
    Liu, Enhai
    Zhang, Zhonglai
    Yu, Zhuang
    Han, Chuang
    Bai, Junqin
    Niu, Huawen
    Zhai, Junjie
    THERMAL SCIENCE, 2021, 25 (03): : 2075 - 2081
  • [43] Numerical Investigation of the Effect of Using CO2 as the Refrigerant in a Heat Pump Tumble Dryer System
    Erdem, Serkan
    Heperkan, Hasan
    DRYING TECHNOLOGY, 2014, 32 (16) : 1923 - 1930
  • [44] Experimental investigation on the heating performance of a CO2 heat pump system with intermediate cooling for electric vehicles
    Chen, Yiyu
    Zou, Huiming
    Dong, Junqi
    Wu, Jiang
    Xu, Hongbo
    Tian, Changqing
    APPLIED THERMAL ENGINEERING, 2021, 182
  • [45] Experimental investigation on a transcritical CO2 air conditioning system for an electric bus
    Song, Xia
    Yu, Binbin
    Lu, Daxiong
    Shi, Junye
    Chen, Jiangping
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 608 - 615
  • [46] Experimental investigation on performance of transcritical CO2 heat pump system with ejector under optimum high-side pressure
    Xu, Xiao Xiao
    Chen, Guang Ming
    Tang, Li Ming
    Zhu, Zhi Jiang
    ENERGY, 2012, 44 (01) : 870 - 877
  • [47] Research on refrigerant charge determination under different compressor speed and its effects on the performance of transcritical CO2 air-conditioning heat pump system in electric vehicle
    Jiang, Ziqi
    Tian, Yafen
    Li, Kang
    Zhao, Zhaorui
    Liu, Ni
    Zhang, Hua
    ENERGY, 2024, 296
  • [48] Experimental Study of a Dual-mode CO2 Heat Pump System with Thermal Storage
    Liu, Fang
    Zhu, Weiquan
    Cai, Yang
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105
  • [49] Experimental study on two types of transcritical CO2 heat pump water heater system
    Chen, Qi
    Tong, Yang
    Li, Mao
    Zhu, Zhijiang
    Tang, Liming
    Chen, Guangming
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2013, 34 (11): : 1903 - 1909
  • [50] EXPERIMENTAL AND SIMULATION STUDY OF TRANSCRITICAL CO2 WATER-WATER HEAT PUMP SYSTEM
    Yang, Junlan
    Zhang, Xin
    Du, Yufan
    Han, Yifei
    Wang, Linxiu
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (08): : 265 - 272