Comparison of an All-Inside Suture Technique With Traditional Pull-Out Suture and Suture Anchor Repair Techniques for Flexor Digitorum Profundus Attachment to Bone

被引:24
作者
Chu, Jennifer Y.
Chen, Tony
Awad, Hani A.
Elfar, John
Hammert, Warren C.
机构
[1] Univ Rochester, Med Ctr, Dept Orthopaed Surg & Rehabil, Ctr Musculoskeletal Res, Rochester, NY 14642 USA
[2] Univ Rochester, Med Ctr, Dept Biomed Engn, Rochester, NY 14642 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2013年 / 38A卷 / 06期
关键词
Flexor digitorum profundus avulsion; flexor digitorum profundus repair; flexor tendon repair; tendon attachment to bone; TENDON REPAIR; BIOMECHANICAL ANALYSIS; ZONE; BUTTON; INJURIES;
D O I
10.1016/j.jhsa.2013.02.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose One goal in repairing zone 1 flexor digitorum profundus (FDP) injuries is to create a tendon-bone construct strong enough to allow early rehabilitation while minimizing morbidity. This study compares an all-inside suture repair technique biomechanically with pull-out suture and double-suture anchor repairs. Methods Repairs were performed on 30 cadaver fingers. In all-inside suture repairs (n = 8), the FDP tendon was attached to bone with two 3-0 Ethibond sutures and tied over the dorsal aspect of distal phalanx. Pull-out suture repairs (n = 8) were performed with 2-0 Prolene suture and tied over a dorsal button. There were 2 suture anchor repair groups: Arthrex Micro Corkscrew anchors preloaded with 2-0 FiberWire suture (n = 7) and Depuy Micro Mitek anchors preloaded with 3-0 Orthocord suture (n = 7). Repair constructs were tested using a servohydraulic materials testing system and loaded until the repair lost 75% of its strength. Results There were no statistically significant differences in tensile stiffness, ultimate load, or work to failure between the repairs. Failure mode was suture stretch and gap formation greater than 2 mm at the repair site for all pull-out suture repairs and for 7 of 8 all-inside suture repairs. Two of the Arthrex Micro Corkscrew repairs and 5 of the Depuy Micro Mitek repairs failed by anchor pull-out. Conclusions This cadaveric biomechanical study showed no difference in tensile stiffness, ultimate load, and work to failures between an all-inside suture repair technique for zone 1 FDP repairs and previously described pull-out suture and suture anchor repair techniques. The all-inside suture technique also has the advantages of avoiding an external button and the cost of anchors. Therefore, it should be considered as an alternative to other techniques. Clinical relevance This study introduces a new FDP reattachment technique that avoids some of the shortcomings of current techniques. (Copyright (C) 2013 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:1084 / 1090
页数:7
相关论文
共 13 条
[1]   Bone suture anchors versus the pullout button for repair of distal profundus tendon injuries: A comparison of strength in human cadaveric hands [J].
Brustein, M ;
Pellegrini, J ;
Choueka, J ;
Heminger, H ;
Mass, D .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (03) :489-496
[2]   The Mantero flexor tendon repair in zone 1 [J].
Guinard, D ;
Montanier, F ;
Thomas, D ;
Corcella, D ;
Moutet, F .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1999, 24B (02) :148-151
[3]   THE MORBIDITY OF THE BUTTON-OVER-NAIL TECHNIQUE FOR ZONE 1 FLEXOR TENDON REPAIRS. SHOULD WE STILL BE USING THIS TECHNIQUE? [J].
Kang, N. ;
Marsh, D. ;
Dewar, D. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2008, 33E (05) :566-570
[4]   A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair [J].
Lawrence, TA ;
Davis, TRC .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04) :836-841
[5]   Repair of Flexor Digitorum Profundus to Distal Phalanx: A Biomechanical Evaluation of Four Techniques [J].
Lee, Steve K. ;
Fajardo, Marc ;
Kardashian, George ;
Klein, Jason ;
Tsai, Peter ;
Christoforou, Dimitrios .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (10) :1604-1609
[6]   Effect of suture material and bone quality on the mechanical properties of zone I flexor tendon-bone reattachment with bone anchors [J].
Matsuzaki, Hironori ;
Zaegel, Melissa A. ;
Gelberman, Richard H. ;
Silva, Matthew J. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (05) :709-717
[7]   Comparison of pullout button versus suture anchor for zone I flexor tendon repair [J].
McCallister, WV ;
Ambrose, HC ;
Katolik, LI ;
Trumble, TE .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (02) :246-251
[8]   Avulsion Injuries of the Flexor Digitorum Profundus Tendon [J].
Ruchelsman, David E. ;
Christoforou, Dimitrios ;
Wasserman, Bradley ;
Lee, Steve K. ;
Rettig, Michael E. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (03) :152-162
[9]   Effect of suture material on gap formation and failure in type 1 FDP avulsion repairs in a cadaver model [J].
Schreuder, F. B. ;
Scougall, P. J. ;
Puchert, E. ;
Vizesi, F. ;
Walsh, W. R. .
CLINICAL BIOMECHANICS, 2006, 21 (05) :481-484
[10]   The effects of multiple-strand suture techniques on the tensile properties of repair of the flexor digitorum profundus tendon to bone [J].
Silva, MJ ;
Hollstien, SB ;
Fayazi, AH ;
Adler, P ;
Gelberman, RH ;
Boyer, MI .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (10) :1507-1514