Posterior Glenoid Wear in Total Shoulder Arthroplasty: Eccentric Anterior Reaming Is Superior to Posterior Augment

被引:27
|
作者
Wang, Tim [1 ]
Abrams, Geoffrey D. [1 ,2 ]
Behn, Anthony W. [1 ]
Lindsey, Derek [2 ]
Giori, Nicholas [2 ]
Cheung, Emilie V. [1 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA 94063 USA
[2] Vet Affairs Palo Alto Hlth Care Syst, Ctr Tissue Regenerat Repair & Restorat, Palo Alto, CA USA
关键词
TOTAL KNEE ARTHROPLASTY; BONE DEFICIENCY; WEDGE AUGMENTATION; COMPONENTS; EROSION; OSTEOARTHRITIS; RETROVERSION; MANAGEMENT; FIXATION; DESIGN;
D O I
10.1007/s11999-015-4482-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Uncorrected glenoid retroversion during total shoulder arthroplasty may lead to an increased likelihood of glenoid prosthetic loosening. Augmented glenoid components seek to correct retroversion to address posterior glenoid bone loss, but few biomechanical studies have evaluated their performance. Questions/purposes We compared the use of augmented glenoid components with eccentric reaming with standard glenoid components in a posterior glenoid wear model. The primary outcome for biomechanical stability in this model was assessed by (1) implant edge displacement in superior and inferior edge loading at intervals up to 100,000 cycles, with secondary outcomes including (2) implant edge load during superior and inferior translation at intervals up to 100,000 cycles, and (3) incidence of glenoid fracture during implant preparation and after cyclic loading. Methods A 12A degrees-posterior glenoid defect was created in 12 composite scapulae, and the specimens were divided in two equal groups. In the posterior augment group, glenoid version was corrected to 8A degrees and an 8A degrees-augmented polyethylene glenoid component was placed. In the eccentric reaming group, anterior glenoid reaming was performed to neutral version and a standard polyethylene glenoid component was placed. Specimens were cyclically loaded in the superoinferior direction to 100,000 cycles. Superior and inferior glenoid edge displacements were recorded. Results Surviving specimens in the posterior augment group showed greater displacement than the eccentric reaming group of superior (1.01 +/- 0.02 [95% CI, 0.89-1.13] versus 0.83 +/- 0.10 [95% CI, 0.72-0.94 mm]; mean difference, 0.18 mm; p = 0.025) and inferior markers (1.36 +/- 0.05 [95% CI, 1.24-1.48] versus 1.20 +/- 0.09 [95% CI, 1.09-1.32 mm]; mean difference, 0.16 mm; p = 0.038) during superior edge loading and greater displacement of the superior marker during inferior edge loading (1.44 +/- 0.06 [95% CI, 1.28-1.59] versus 1.16 +/- 0.11 [95% CI, 1.02-1.30 mm]; mean difference, 0.28 mm; p = 0.009) at 100,000 cycles. No difference was seen with the inferior marker during inferior edge loading (0.93 +/- 0.15 [95% CI, 0.56-1.29] versus 0.78 +/- 0.06 [95% CI, 0.70-0.85 mm]; mean difference, 0.15 mm; p = 0.079). No differences in implant edge load were seen during superior and inferior loading. There were no instances of glenoid vault fracture in either group during implant preparation; however, a greater number of specimens in the eccentric reaming group were able to achieve the final 100,000 time without catastrophic fracture than those in the posterior augment group. Conclusions When addressing posterior glenoid wear in surrogate scapula models, use of angle-backed augmented glenoid components results in accelerated implant loosening compared with neutral-version glenoid after eccentric reaming, as shown by increased implant edge displacement at analogous times.
引用
收藏
页码:3928 / 3936
页数:9
相关论文
共 50 条
  • [31] Glenoid articular conformity affects stress distributions in total shoulder arthroplasty
    Zhang, Jingzhou
    Yongpravat, Charlie
    Kim, H. Mike
    Levine, William N.
    Bigliani, Louis U.
    Gardner, Thomas R.
    Ahmad, Christopher S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (03) : 350 - 356
  • [32] Posterior open wedge glenoid osteotomy provides reliable results in young patients with increased glenoid retroversion and posterior shoulder instability
    Lacheta, Lucca
    Singh, Taran S. P.
    Hovsepian, Jean M.
    Braun, Sepp
    Imhoff, Andreas B.
    Pogorzelski, Jonas
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (01) : 299 - 304
  • [33] Posterior open wedge glenoid osteotomy provides reliable results in young patients with increased glenoid retroversion and posterior shoulder instability
    Lucca Lacheta
    Taran S. P. Singh
    Jean M. Hovsepian
    Sepp Braun
    Andreas B. Imhoff
    Jonas Pogorzelski
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 299 - 304
  • [34] Total Shoulder Arthroplasty Using OVO®/OVO® Motion with Inlay Glenoid Shoulder Arthroplasty System
    Yalcin, Sercan
    Scarcella, Michael
    Miniaci, Anthony
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 38
  • [35] Posterior-approach total shoulder arthroplasty: a case series with a minimum of 2-year outcomes
    Kohrs, Brandon
    Nolan, Joseph R.
    Greiwe, R. Michael
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (12) : 2778 - 2785
  • [36] Long-term results after posterior open glenoid wedge osteotomy for posterior shoulder instability associated with excessive glenoid retroversion
    Waltenspuel, Manuel
    Haeller, Thomas
    Ernstbrunner, Lukas
    Wyss, Sabine
    Wieser, Karl
    Gerber, Christian
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (01) : 81 - 89
  • [37] Mid-term results of reverse shoulder arthroplasty for glenohumeral osteoarthritis with posterior glenoid deficiency and humeral subluxation
    Collin, Philippe
    Herve, Anthony
    Walch, Gilles
    Boileau, Pascal
    Muniandy, Moganadass
    Chelli, Mickael
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (10) : 2023 - 2030
  • [38] A comparison of onlay versus inlay glenoid component loosening in total shoulder arthroplasty
    Gagliano, Jeffrey R.
    Helms, Sarah M.
    Colbath, Gregory P.
    Przestrzelski, Breanne T.
    Hawkins, Richard J.
    DesJardins, John D.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (07) : 1113 - 1120
  • [39] Reverse total shoulder arthroplasty with structural bone grafting of large glenoid defects
    Jones, Richard B.
    Wright, Thomas W.
    Zuckerman, Joseph D.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (09) : 1425 - 1432
  • [40] Glenoid bone grafting in primary reverse total shoulder arthroplasty
    Ernstbrunner, Lukas
    Werthel, Jean-David
    Wagner, Eric
    Hatta, Taku
    Sperling, John W.
    Cofield, Robert H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (08) : 1441 - 1447