Posterior Glenoid Wear in Total Shoulder Arthroplasty: Eccentric Anterior Reaming Is Superior to Posterior Augment

被引:27
|
作者
Wang, Tim [1 ]
Abrams, Geoffrey D. [1 ,2 ]
Behn, Anthony W. [1 ]
Lindsey, Derek [2 ]
Giori, Nicholas [2 ]
Cheung, Emilie V. [1 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA 94063 USA
[2] Vet Affairs Palo Alto Hlth Care Syst, Ctr Tissue Regenerat Repair & Restorat, Palo Alto, CA USA
关键词
TOTAL KNEE ARTHROPLASTY; BONE DEFICIENCY; WEDGE AUGMENTATION; COMPONENTS; EROSION; OSTEOARTHRITIS; RETROVERSION; MANAGEMENT; FIXATION; DESIGN;
D O I
10.1007/s11999-015-4482-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Uncorrected glenoid retroversion during total shoulder arthroplasty may lead to an increased likelihood of glenoid prosthetic loosening. Augmented glenoid components seek to correct retroversion to address posterior glenoid bone loss, but few biomechanical studies have evaluated their performance. Questions/purposes We compared the use of augmented glenoid components with eccentric reaming with standard glenoid components in a posterior glenoid wear model. The primary outcome for biomechanical stability in this model was assessed by (1) implant edge displacement in superior and inferior edge loading at intervals up to 100,000 cycles, with secondary outcomes including (2) implant edge load during superior and inferior translation at intervals up to 100,000 cycles, and (3) incidence of glenoid fracture during implant preparation and after cyclic loading. Methods A 12A degrees-posterior glenoid defect was created in 12 composite scapulae, and the specimens were divided in two equal groups. In the posterior augment group, glenoid version was corrected to 8A degrees and an 8A degrees-augmented polyethylene glenoid component was placed. In the eccentric reaming group, anterior glenoid reaming was performed to neutral version and a standard polyethylene glenoid component was placed. Specimens were cyclically loaded in the superoinferior direction to 100,000 cycles. Superior and inferior glenoid edge displacements were recorded. Results Surviving specimens in the posterior augment group showed greater displacement than the eccentric reaming group of superior (1.01 +/- 0.02 [95% CI, 0.89-1.13] versus 0.83 +/- 0.10 [95% CI, 0.72-0.94 mm]; mean difference, 0.18 mm; p = 0.025) and inferior markers (1.36 +/- 0.05 [95% CI, 1.24-1.48] versus 1.20 +/- 0.09 [95% CI, 1.09-1.32 mm]; mean difference, 0.16 mm; p = 0.038) during superior edge loading and greater displacement of the superior marker during inferior edge loading (1.44 +/- 0.06 [95% CI, 1.28-1.59] versus 1.16 +/- 0.11 [95% CI, 1.02-1.30 mm]; mean difference, 0.28 mm; p = 0.009) at 100,000 cycles. No difference was seen with the inferior marker during inferior edge loading (0.93 +/- 0.15 [95% CI, 0.56-1.29] versus 0.78 +/- 0.06 [95% CI, 0.70-0.85 mm]; mean difference, 0.15 mm; p = 0.079). No differences in implant edge load were seen during superior and inferior loading. There were no instances of glenoid vault fracture in either group during implant preparation; however, a greater number of specimens in the eccentric reaming group were able to achieve the final 100,000 time without catastrophic fracture than those in the posterior augment group. Conclusions When addressing posterior glenoid wear in surrogate scapula models, use of angle-backed augmented glenoid components results in accelerated implant loosening compared with neutral-version glenoid after eccentric reaming, as shown by increased implant edge displacement at analogous times.
引用
收藏
页码:3928 / 3936
页数:9
相关论文
共 50 条
  • [21] Midterm radiographic outcomes of anatomic total shoulder arthroplasty in biplanar glenoid deformities
    Olson, Jeffrey J.
    Hill, J. Ryan
    Buchman, Brett
    Aleem, Alexander W.
    Keener, Jay D.
    Zmistowski, Benjamin M.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (04) : 1043 - 1050
  • [22] Total shoulder arthroplasty with an uncemented soft-metal-backed glenoid component
    Fucentese, Sandro F.
    Costouros, John G.
    Kuehnel, Stefanie-Peggy
    Gerber, Christian
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (04) : 624 - 631
  • [23] Total shoulder arthroplasty for glenohumeral arthritis associated with posterior glenoid bone loss: midterm results of an all-polyethylene, posteriorly augmented, stepped glenoid component
    Debernardis, Dennis
    Donnelly, David
    Bahel, Aditya
    Favorito, Paul
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (01) : 51 - 61
  • [24] Is the Posterior Approach With Posterior locking compression plate and Anterior Allograft Useful and Safe in the Treatment of Periprosthetic Humeral Fractures Following Reverse Total Shoulder Arthroplasty?
    Vicenti, Giovanni
    Solarino, Giuseppe
    Carrozzo, Massimiliano
    Simone, Filippo
    Ottaviani, Guglielmo
    Bizzoca, Davide
    Zavattini, Giacomo
    Zaccari, Domenico
    Buono, Claudio
    Moretti, Biagio
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13
  • [25] Comparison of Glenoid Version and Posterior Humeral Subluxation in Patients With and Without Posterior Shoulder Instability
    Parada, Stephen A.
    Eichinger, Josef K.
    Dumont, Guillaume D.
    Burton, Lauren E.
    Coats-Thomas, Maggie S.
    Daniels, Stephen D.
    Sinz, Nathan J.
    Provencher, Matthew T.
    Higgins, Laurence D.
    Warner, Jon J. P.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (02) : 254 - 260
  • [26] Anatomic shoulder arthroplasty with high side reaming versus reverse shoulder arthroplasty for eccentric glenoid wear patterns with an intact rotator cuff: comparing early versus midterm outcomes with minimum 7 years of follow-up
    Cuff, Derek J.
    Simon, Peter
    Patel, Jay S.
    Munassi, Steven D.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (05) : 972 - 979
  • [27] The posterior condylar offset ratio and femoral anatomy in anterior versus posterior referencing total knee arthroplasty
    Almeida, P. H.
    Vilaca, A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (06) : 687 - 691
  • [28] Glenoid implant orientation and cement failure in total shoulder arthroplasty: a finite element analysis
    Yongpravat, Charlie
    Kim, H. Mike
    Gardner, Thomas R.
    Bigliani, Louis U.
    Levine, William N.
    Ahmad, Christopher S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (07) : 940 - 947
  • [29] The effects of glenoid wear patterns on patients with osteoarthritis in total shoulder arthroplasty: an assessment of outcomes and value
    Hussey, Michael M.
    Steen, Brandon M.
    Cusick, Michael C.
    Cox, Jacob L.
    Marberry, Scott T.
    Simon, Peter
    Cottrell, Benjamin J.
    Santoni, Brandon G.
    Frankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (05) : 682 - 690
  • [30] Advances in Glenoid Design in Anatomic Total Shoulder Arthroplasty
    Trivedi, Nikunj N.
    Shimberg, Jilan L.
    Sivasundaram, Lakshmanan
    Mengers, Sunita
    Salata, Michael J.
    Voos, James E.
    Gillespie, Robert J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (20) : 1825 - 1835