Quality assessment and transfusion efficacy of buffy coat-derived platelet concentrates washed with platelet additive solution

被引:6
|
作者
Fernandez-Munoz, Hermogenes [1 ,2 ]
Castilla-Llorente, Cristina [1 ,3 ]
Plaza, Eva M. [1 ]
Martinez-Millan, Cristina [1 ]
Heras, Inmaculada [1 ]
Iniesta, Pastora [1 ]
Amigo, Maria L. [1 ]
Ferrer-Marin, Francisca [1 ]
Candela, Maria J. [1 ]
Lozano, Maria L. [1 ]
Vicente, Vicente [1 ]
Rivera, Jose [1 ]
机构
[1] Univ Murcia, Morales Meseguer Univ Hosp, Reg Blood Donat Ctr, Haematol & Med Oncol Serv,IMIB Arrixaca,CIBERER, Murcia, Spain
[2] Rafael Mendez Univ Hosp, Haematol & Blood Therapy Serv, Lorca, Spain
[3] Gustave Roussy Inst, Haematol Serv, Villejuif, France
关键词
washed platelet concentrates; washed platelet function; washed platelet transfusion; VerifyNow (R) system; IN-VITRO QUALITY; WASHING PLATELETS; STORAGE; SYSTEM; REFRACTORINESS; APHERESIS; REMOVAL;
D O I
10.2450/2017.0277-16
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transfusion of washed platelet concentrates (W-PC) is recommended for some patients, such as those who have had previous severe allergic transfusion reactions. However, we still lack a standardised method for preparing these products. Here, we assessed the effect of a manual washing procedure on in vitro platelet quality and on the transfusion efficacy of W-PCs. Materials and methods. Buffy coat-derived W-PC in Composol solution were prepared by one-step centrifugation. Platelet activation and function were evaluated before and after washing by means of: (i) CD62 expression by flow cytometry; (ii) platelet aggregation (LTA); and (iii) the VerifyNow (R) P2Y12 test. A pilot prospective transfusion study was carried out in 11 onco-hematology patients receiving, in a short time, two consecutive transfusions: one with standard PC (S-PC) and one with W-PC. The post-transfusion platelet increment, the 1 h and 24 h corrected count increment (CCI) and occurrence of bleeding events were used as indices of transfusion efficacy. Results. Platelet recovery in W-PC was 84.8 +/- 5.4%. Washing slightly increased platelet activation in W-PC vs pre-washed samples (% CD62+ platelets 23.6 +/- 7 vs 14.8 +/- 1; p=0.03). As compared to prewash samples, platelet reactivity of W-PC as measured by VerifyNow (R) P2Y12 was significantly lower with ADP (PRU 32.2 +/- 37.7 vs 4.2 +/- 2.4, p=0.027), but similar using TRAP. Platelet aggregation responses to TRAP, collagen, ristocetin and arachidonic acid were maintained in W-PC. The pilot transfusion trial showed similar 1 h (13.5 +/- 5.6 vs 11.5 +/- 7.3, p=0.49) and 24 h (11 +/- 7.2 vs 9 +/- 6.5, p=0.48) CCI for S-PC and W-PC. Transfusion of W-PC was not associated with an increased number of bleeding events. Discussion. We have set up a simple method to obtain buffy-coat-derived W-PC, which has minor effects on in vitro platelet quality and transfusion effectiveness. This procedure can be easily implemented in transfusion centres for on-demand preparation of washed platelets.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 50 条
  • [1] Cryopreservation of buffy-coat-derived platelet concentrates in dimethyl sulfoxide and platelet additive solution
    Johnson, L. N.
    Winter, K. M.
    Reid, S.
    Hartkopf-Theis, T.
    Marks, D. C.
    CRYOBIOLOGY, 2011, 62 (02) : 100 - 106
  • [2] Cryopreservation of buffy coat-derived platelet concentrates photochemically treated with amotosalen and UVA light
    Meinke, Stephan
    Wikman, Agneta
    Gryfelt, Gunilla
    Hultenby, Kjell
    Uhlin, Michael
    Hoeglund, Petter
    Sandgren, Per
    TRANSFUSION, 2018, 58 (11) : 2657 - 2668
  • [3] Platelet activation of platelet concentrates derived from buffy coat and apheresis methods
    Ali, Soleimany Ferizhandy
    TRANSFUSION AND APHERESIS SCIENCE, 2011, 44 (01) : 11 - 13
  • [4] Superior integrin activating capacity and higher adhesion to fibrinogen matrix in buffy coat-derived platelet concentrates (PCs) compared to PRP-PCs
    Beshkar, Pezhman
    Hosseini, Ehteramolsadat
    Ghasemzadeh, Mehran
    TRANSFUSION AND APHERESIS SCIENCE, 2018, 57 (01) : 76 - 81
  • [5] Quality assessment of buffy-coat-derived leucodepleted platelet concentrates in PAS-plasma, prepared by the OrbiSac or TACSI automated system
    Plaza, E. M.
    Cespedes, P.
    Fernandez, H.
    Sanchez-Guiu, M. I.
    Egea, J. M.
    Vicente, V.
    Lozano, M. L.
    Rivera, J.
    VOX SANGUINIS, 2014, 106 (01) : 38 - 44
  • [6] Platelet concentrates derived from buffy coat and apheresis:: biochemical and functional differences
    Böck, M
    Rahrig, S
    Kunz, D
    Lutze, G
    Heim, MU
    TRANSFUSION MEDICINE, 2002, 12 (05) : 317 - 324
  • [7] Soluble CD40L and CD62P levels differ in single-donor apheresis platelet concentrates and buffy coat-derived pooled platelet concentrates
    Sut, Caroline
    Tariket, Sofiane
    Aloui, Chaker
    Arthaud, Charles-Antoine
    Eyraud, Marie-Ange
    Fagan, Jocelyne
    Chavarin, Patricia
    Hamzeh-Cognasse, Hind
    Laradi, Sandrine
    Garraud, Olivier
    Cognasse, Fabrice
    TRANSFUSION, 2019, 59 (01) : 16 - 20
  • [8] The history of buffy coat platelet concentrates: The Dutch story
    van der Meer, Pieter F.
    Reesink, Hendrik W.
    de Korte, Dirk
    Loos, Johannes A.
    Klei, Thomas R. L.
    VOX SANGUINIS, 2022, 117 (07) : 913 - 919
  • [9] Comparative analysis of the quality of platelet concentrates produced by apheresis procedures, platelet rich plasma, and buffy coat
    Li, Meng
    Zhao, Yuwei
    Chen, Xue
    Du, Xinman
    Luo, Yue
    Li, Ying
    Kang, Jianxun
    Wan, Like
    Tang, Jingyun
    Fu, Xuemei
    TRANSFUSION, 2024, 64 (02) : 367 - 379
  • [10] Comparison of the platelet-rich plasma and buffy coat protocols for preparation of canine platelet concentrates
    Hoareau, Guillaume L.
    Jandrey, Karl E.
    Burges, Julie
    Bremer, Daphne
    Tablin, Fern
    VETERINARY CLINICAL PATHOLOGY, 2014, 43 (04) : 513 - 518