Molecularly imprinted polymeric coatings for sensitive and selective gravimetric detection of artemether

被引:16
作者
Arshad, Usman [1 ]
Mujahid, Adnan [1 ]
Lieberzeit, Peter [2 ]
Afzal, Adeel [3 ]
Bajwa, Sadia Zafar [4 ]
Iqbal, Naseer [3 ]
Roshan, Sumaira [1 ]
机构
[1] Univ Punjab, Inst Chem, Lahore 54590, Pakistan
[2] Univ Vienna, Dept Phys Chem, Waehringer Str 42, A-1090 Vienna, Austria
[3] Univ Hafr Al Batin, Coll Sci, Dept Chem, POB 1803, Hafar al Batin 39524, Saudi Arabia
[4] Natl Inst Biotechnol & Genet Engn, Jhang Rd, Faisalabad, Pakistan
关键词
METABOLITE DIHYDROARTEMISININ; VOLTAMMETRIC SENSOR; EFFICIENT MODIFIER; MASS-SPECTROMETRY; LUMEFANTRINE; ELECTRODE; DESIGN; PLASMA; NANOPARTICLES; QUANTITATION;
D O I
10.1039/d0ra04785f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Monitoring antimalarial drugs is necessary for clinical assays, human health, and routine quality control practices in pharmaceutical industries. Herein, we present the development of sensor coatings based on molecularly imprinted polymers (MIPs) combined with quartz crystal microbalance (QCM) for sensitive and selective gravimetric detection of an antimalarial drug: artemether. The MIP coatings are synthesized by using artemether as the template in a poly(methacrylic acid-co-ethylene glycol dimethacrylate) matrix. Artemether-MIP and the non-imprinted polymer (NIP) control or reference layers are deposited on 10 MHz dual-electrode QCM by spin coating (187 +/- 9 nm layer thickness after optimization). The coatings are characterized by FTIR spectroscopy and atomic force microscopy that reveal marked differences among the MIP and NIP. The MIP-QCM sensor exhibits high sensitivity (0.51 Hz ppm(-1)) with sub-10 ppm detection and quantification limits. The MIP-QCM sensor also exhibits a 6-fold higher sensitivity compared to the NIP-QCM, and a dynamic working range of 30-100 ppm. The response time of MIP-QCM devices for a single cycle of analyte adsorption, signal saturation, and MIP regeneration is less than 2.5 min. The sensor also demonstrates selectivity factors of artemether-MIP of 2.2 and 4.1 compared to artemisinin and lumefantrine, respectively. Reversibility tests reveal less than 5% variation in sensor responses over three cycles of measurements at each tested concentration. The MIP-QCM showed lower detection limits than conventional HPLC-UV, and faster response time compared to HPLC-UV and liquid chromatography-mass spectrometry (LC-MS).
引用
收藏
页码:34355 / 34363
页数:9
相关论文
共 41 条
  • [1] A collaborative effect of imprinted polymers and Au nanoparticles on bioanalogous detection of organic vapors
    Afzal, Adeel
    Feroz, Saima
    Iqbal, Naseer
    Mujahid, Adnan
    Rehman, Abdul
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 431 - 439
  • [2] Determination of artemether and lumefantrine in anti-malarial fixed-dose combination tablets by microemulsion electrokinetic chromatography with short-end injection procedure
    Amin, N'Cho Christophe
    Fabre, Huguette
    Blanchin, Marie-Dominique
    Montels, Jerome
    Ake, Michele
    [J]. MALARIA JOURNAL, 2013, 12
  • [3] [Anonymous], 2015, GUID TREATM MAL
  • [4] Arun R., 2011, International Journal Pharmaceutical and Biomedical Research, V2, P201
  • [5] A novel sensitive electrochemical sensor based on in-situ polymerized molecularly imprinted membranes at graphene modified electrode for artemisinin determination
    Bai, Huiping
    Wang, Chunqiong
    Chen, Jing
    Peng, Jun
    Cao, Qiue
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 64 : 352 - 358
  • [6] Liquid chromatography-tandem mass spectrometry for the simultaneous quantitation of artemether and lumefantrine in human plasma: Application for a pharmacokinetic study
    Cesar, Isabela Costa
    de Aquino Ribeiro, Jose Antonio
    Teixeira, Leonardo de Souza
    Bellorio, Karini Bruno
    de Abreu, Fernanda Crunivel
    Moreira, Josianny Mesquita
    Chellini, Paula Rocha
    Pianetti, Gerson Antonio
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 114 - 120
  • [7] Simultaneous determination of artemether and lumefantrine in fixed dose combination tablets by HPLC with UV detection
    Cesar, Isabela da Costa
    Andrade Nogueira, Fernando Henrique
    Pianetti, Gerson Antonio
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (03) : 951 - 954
  • [8] César ID, 2009, BRAZ J PHARM SCI, V45, P737
  • [9] Recent applications of molecular imprinted polymers for enantio-selective recognition
    Cheong, Won Jo
    Ali, Faiz
    Choi, Ji Ho
    Lee, Jin Ook
    Sung, Kim Yune
    [J]. TALANTA, 2013, 106 : 45 - 59
  • [10] Optimizing derivatization conditions using an experimental design and simultaneous estimation of artemether and lumefantrine by ratio first order derivative spectrophotometric method
    Christian, Jenee
    Shah, Purvi
    Patel, Margi
    Patel, Kalpana
    Gandhi, Tejal