The biomechanical effect of artificial and human bone density on stopping and stripping torque during screw insertion

被引:40
|
作者
Tsuji, Matthew [1 ]
Crookshank, Meghan [1 ,2 ]
Olsen, Michael [1 ,2 ]
Schemitsch, Emil H. [1 ,2 ]
Zdero, Racl [2 ,3 ]
机构
[1] Univ Toronto, Fac Med, Toronto, ON M5S 1A8, Canada
[2] Lab St Michaels Hosp, Martin Orthoped Biomech, Toronto, ON M5B 1W8, Canada
[3] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
关键词
Biomechanics; Artificial; Human; Density; Cortical; Cancellous; Stopping torque; Stripping torque; CANCELLOUS BONE; FRACTURE FIXATION; BENDING STRENGTH; PULLOUT STRENGTH; PEDICLE SCREWS; HOLDING POWER; FEMUR; SHAFT; HIP;
D O I
10.1016/j.jmbbm.2013.03.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Orthopedic surgeons apply torque to metal screws manually by "subjective feel" to obtain adequate fracture fixation, i.e. stopping torque, and attempt to avoid accidental overtightening that leads to screw-bone interface failure, i.e. stripping torque. Few studies have quantified stripping torque in human bone, and only one older study from 1980 reported stopping/stripping torque ratio. The present aim was to measure stopping and stripping torque of cortical and cancellous screws in artificial and human bone over a wide range of densities. Sawbone blocks were obtained having densities from 0.08 to 0.80 g/cm(3). Sixteen fresh-frozen human femurs of known standardized bone mineral density (sBMD) were also used. Using a torque screwdriver, 3.5-mm diameter cortical screws and 6.5-mm diameter cancellous screws were inserted for adequate tightening as determined subjectively by an orthopedic surgeon, i.e. stopping torque, and then further tightened until failure of the screw-bone interface, i.e. stripping torque. There were weak (R=0.25) to strong (R=0.99) linear correlations of absolute and normalized torque vs. density or sBMD. Maximum stopping torques normalized by screw thread area engaged by the host material were 15.2 N/mm (cortical screws) and 13.4 N/mm (cancellous screws) in sawbone blocks and 20.9 N/mm (cortical screws) and 6.1 N/mm (cancellous screws) in human femurs. Maximum stripping torques normalized by screw thread area engaged by the host material were 23.4 N/mm (cortical screws) and 16.8 N/mm (cancellous screws) in sawbone blocks and 29.3 N/mm (cortical screws) and 8.3 N/mm (cancellous screws) in human femurs. Combined average stopping/ stripping torque ratios were 80.8% (cortical screws) and 76.8% (cancellous screws) in sawbone blocks, as well as 66.6% (cortical screws) and 84.5% (cancellous screws) in human femurs. Surgeons should be aware of stripping torque limits for human femurs and monitor stopping torque during surgery. This is the first study of the effect of sawbone density or human bone sBMD on stopping and stripping torque. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:146 / 156
页数:11
相关论文
共 50 条
  • [21] Screw insertion torque as parameter to judge the fixation. Assessment of torque and pull-out strength in different bone densities and screw-pitches
    Addevico, Francesco
    Morandi , Massimo
    Scaglione, Michelangelo
    Solitro, Giovanni F.
    CLINICAL BIOMECHANICS, 2020, 72 : 130 - 135
  • [22] Histologic and Biomechanical Evaluation of the Effects of Implant Insertion Torque on Peri-Implant Bone Healing
    Consolo, Ugo
    Travaglini, Domenico
    Todisco, Marzio
    Trisi, Paolo
    Galli, Silvia
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (03) : 860 - 865
  • [23] Value of different preoperative bone evaluation methods in predicting intraoperative screw insertion torque: a prospective clinical comparative trial
    Yin, Houjie
    Lin, Wentao
    Zheng, Guanghao
    Yang, Ruobing
    Xie, Faqin
    Yuan, Weiquan
    Chen, Tao
    Mao, Raobing
    Wang, Xiaoqian
    Wang, Zhiyun
    SPINE JOURNAL, 2024, 24 (10) : 1833 - 1843
  • [24] Effect of pilot hole on biomechanical and in vivo pedicle screw–bone interface
    Patrícia Silva
    Rodrigo César Rosa
    Antonio Carlos Shimano
    Helton L. A. Defino
    European Spine Journal, 2013, 22 : 1829 - 1836
  • [25] Biomechanical analysis analyzing association between bone mineral density and lag screw migration
    Lee, Hyeonjoon
    Kim, Soo Ah
    Jo, Sungmin
    Jo, Suenghwan
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [26] Bone density and insertion torque as predictors of anterior cruciate ligament graft fixation strength
    Järvinen, TLN
    Nurmi, JT
    Sievänen, H
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (06) : 1421 - 1429
  • [27] Pullout strength of cancellous screws in human femoral heads depends on applied insertion torque, trabecular bone microarchitecture and areal bone mineral density
    Ab-Lazid, Rosidah
    Perilli, Egon
    Ryan, Melissa K.
    Costi, John J.
    Reynolds, Karen J.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 40 : 354 - 361
  • [28] The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models
    Patel, Purvi S. D.
    Shepherd, Duncan E. T.
    Hukins, David W. L.
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (08) : 822 - 828
  • [29] The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation
    Lee, J. H.
    Lee, J-H.
    Park, J. W.
    Shin, Y. H.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (01): : 93 - 97
  • [30] Screw Insertion in Osteoporotic Bone: Turn-of-the-Nut and Torque-Based Techniques Provide Similar Resistance to Bone Plate Slippage
    Mears, Simon C.
    Langdale, Evan R.
    Belkoff, Stephen M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (02) : E65 - E68