Contactless Vibrational Analysis of Transparent Hydrogel Structures Using Laser-Doppler Vibrometry

被引:11
|
作者
Schwarz, S. [1 ,2 ,3 ]
Hartmann, B. [1 ,3 ]
Sauer, J. [4 ]
Burgkart, R. [5 ]
Sudhop, S. [1 ,3 ]
Rixen, D. J. [2 ]
Clausen-Schaumann, H. [1 ,3 ]
机构
[1] Munich Univ Appl Sci, Ctr Appl Tissue Engn & Regenerat Med, Lothstr 34, D-80335 Munich, Germany
[2] Tech Univ Munich, Dept Mech Engn, D-85748 Garching, Germany
[3] Ludwig Maximilians Univ Munchen, Ctr NanoSci, D-80799 Munich, Germany
[4] Polytec GmbH, D-76337 Waldbronn, Germany
[5] Tech Univ Munich, Klin & Poliklin Orthopadie & Sportorthopadie, D-81675 Munich, Germany
关键词
LDV; Mechanical properties; Biomaterials; Atomic force microscopy (AFM); Compression testing; MECHANICAL-PROPERTIES; ARTICULAR-CARTILAGE; MIGRATION; GROWTH; MORPHOGENESIS; ELASTICITY; BEHAVIOR; CELLS; WATER;
D O I
10.1007/s11340-020-00626-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background Investigating the mechanical properties of biological and biocompatible hydrogels is important in tissue engineering and biofabrication. Atomic force microscopy (AFM) and compression testing are routinely used to determine mechanical properties of tissue and tissue constructs. However, these techniques are slow and require mechanical contact with the sample, rendering in situ measurements difficult. Objective We therefore aim at a fast and contactless method for determining the mechanical properties of biological hydrogels and investigate if an optical method, like Laser-Doppler vibrometry (LDV), can accomplish this task. Methods LDV is a fast contactless method for mechanical analysis. Nonetheless, LDV setups operating in the visible range of the optical spectrum are difficult to use for transparent materials, such as biological hydrogels, because LDV relies on reflected or back-scattered light from the sample. We therefore use a near-infrared (NIR) scanning LDV to determine the vibration spectra of cylindrical gelatin discs of different gelatin concentration and compare the results to AFM data and unconfined compression testing. Results We show that the gelatin test structures can be analyzed, using a NIR LDV, and the Young's moduli can be deduced from the resonance frequencies of the first normal (0,1) mode of these structures. As expected, the frequency of this mode increases with the square root of the Young's modulus and the damping constant increases exponentially with gelatin concentration, which underpins the validity of our approach. Conclusions Our results demonstrate that NIR wavelengths are suitable for a fast, contactless vibrational analysis of transparent hydrogel structures.
引用
收藏
页码:1067 / 1078
页数:12
相关论文
共 50 条
  • [41] Enhancing Multichannel Laser-Doppler Vibrometry Signals with Application to (Carotid-Femoral) Pulse Transit Time Estimation
    Beeckman, Simeon
    Li, Yanlu
    Aasmul, Soren
    Baets, Roel
    Boutouyrie, Pierre
    Segers, Patrick
    Madhu, Nilesh
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [42] Determination of the excitation spectrum for contactless broadband measurements of the frequency response function with plasma excitation and laser Doppler vibrometry
    Cao, Xiaodong
    Yu, Mengwei
    Bauer, Georg
    Rembe, Christian
    TM-TECHNISCHES MESSEN, 2020, 87 (s1) : S102 - S107
  • [43] Development of a robot-aided modal analysis measurement method using laser Doppler vibrometry
    Devigne, O.
    Hoffait, S.
    Bruls, O.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2020) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2020), 2020, : 1847 - 1858
  • [44] PULSE-WAVE DETECTION AND ANALYSIS IN HUMAN TEETH USING LASER-DOPPLER FLOWMETRY
    SCHULER, J
    VOSS, A
    DETTENHOFER, G
    CASCORBI, I
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 919 - 919
  • [45] Structural damage assessment in composite material using Laser Doppler Vibrometry
    Willemann, DP
    Castellini, P
    Revel, GM
    Tomasini, EP
    SIXTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 2004, 5503 : 375 - 379
  • [46] Fast loose rivet detection by using Scanning Laser Doppler Vibrometry
    Stamm, M.
    Schlemme-Weber, S.
    Appl, S.
    Koeser, J.
    Pfeiffer, H.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2020) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2020), 2020, : 2843 - 2853
  • [47] Load/unload measurements using laser doppler vibrometry and acoustic emission
    Weissner, S
    Talke, FE
    TRIBOLOGY INTERNATIONAL, 2000, 33 (5-6) : 367 - 372
  • [48] New Aspects in the Clinical Diagnosis of Otosclerosis Using Laser Doppler Vibrometry
    Jakob, Andre
    Bornitz, Matthias
    Kuhlisch, Eberhard
    Zahnert, Thomas
    OTOLOGY & NEUROTOLOGY, 2009, 30 (08) : 1049 - 1057
  • [49] Evaluation of a Slider with an Integrated Magnetic Microactuator Using Laser Doppler Vibrometry
    Dinulovic, D.
    Ruffert, C.
    Saalfeld, H.
    Gatzen, H. H.
    ACTUATOR 10, CONFERENCE PROCEEDINGS, 2010, : 774 - 777
  • [50] Visualising scattering underwater acoustic fields using laser Doppler vibrometry
    Harland, A. R.
    Petzing, J. N.
    Tyrer, J. R.
    JOURNAL OF SOUND AND VIBRATION, 2007, 305 (4-5) : 659 - 671