Contactless Vibrational Analysis of Transparent Hydrogel Structures Using Laser-Doppler Vibrometry

被引:11
|
作者
Schwarz, S. [1 ,2 ,3 ]
Hartmann, B. [1 ,3 ]
Sauer, J. [4 ]
Burgkart, R. [5 ]
Sudhop, S. [1 ,3 ]
Rixen, D. J. [2 ]
Clausen-Schaumann, H. [1 ,3 ]
机构
[1] Munich Univ Appl Sci, Ctr Appl Tissue Engn & Regenerat Med, Lothstr 34, D-80335 Munich, Germany
[2] Tech Univ Munich, Dept Mech Engn, D-85748 Garching, Germany
[3] Ludwig Maximilians Univ Munchen, Ctr NanoSci, D-80799 Munich, Germany
[4] Polytec GmbH, D-76337 Waldbronn, Germany
[5] Tech Univ Munich, Klin & Poliklin Orthopadie & Sportorthopadie, D-81675 Munich, Germany
关键词
LDV; Mechanical properties; Biomaterials; Atomic force microscopy (AFM); Compression testing; MECHANICAL-PROPERTIES; ARTICULAR-CARTILAGE; MIGRATION; GROWTH; MORPHOGENESIS; ELASTICITY; BEHAVIOR; CELLS; WATER;
D O I
10.1007/s11340-020-00626-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background Investigating the mechanical properties of biological and biocompatible hydrogels is important in tissue engineering and biofabrication. Atomic force microscopy (AFM) and compression testing are routinely used to determine mechanical properties of tissue and tissue constructs. However, these techniques are slow and require mechanical contact with the sample, rendering in situ measurements difficult. Objective We therefore aim at a fast and contactless method for determining the mechanical properties of biological hydrogels and investigate if an optical method, like Laser-Doppler vibrometry (LDV), can accomplish this task. Methods LDV is a fast contactless method for mechanical analysis. Nonetheless, LDV setups operating in the visible range of the optical spectrum are difficult to use for transparent materials, such as biological hydrogels, because LDV relies on reflected or back-scattered light from the sample. We therefore use a near-infrared (NIR) scanning LDV to determine the vibration spectra of cylindrical gelatin discs of different gelatin concentration and compare the results to AFM data and unconfined compression testing. Results We show that the gelatin test structures can be analyzed, using a NIR LDV, and the Young's moduli can be deduced from the resonance frequencies of the first normal (0,1) mode of these structures. As expected, the frequency of this mode increases with the square root of the Young's modulus and the damping constant increases exponentially with gelatin concentration, which underpins the validity of our approach. Conclusions Our results demonstrate that NIR wavelengths are suitable for a fast, contactless vibrational analysis of transparent hydrogel structures.
引用
收藏
页码:1067 / 1078
页数:12
相关论文
共 50 条
  • [11] Laser Doppler vibrometry at dynamic structures of wind turbines
    Goehler, Benjamin
    Lutzmann, Peter
    Scherer-Kloeckling, Clemens
    Brunner, Simon
    Kaufmann, Ilja
    TM-TECHNISCHES MESSEN, 2020, 87 (06) : 392 - 403
  • [12] An adaptive continuous scanning laser Doppler vibrometry technique for measuring vibrational mode shapes of structures with holes
    Zhang, Lei
    Zang, Chaoping
    Jing, Tong
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (11)
  • [13] Diagnostic utility of laser-Doppler vibrometry in conductive hearing loss with normal tympanic membrane
    Rosowski, JJ
    Mehta, RP
    Merchant, SN
    OTOLOGY & NEUROTOLOGY, 2003, 24 (02) : 165 - 175
  • [14] MEMS characterization using laser Doppler vibrometry
    Lawrence, EM
    Speller, KE
    Yu, DL
    RELIABILITY, TESTING, AND CHARACTERIZATION OF MEMS/MOEMS II, 2003, 4980 : 51 - 62
  • [15] Damage detection of civil concrete structures by laser Doppler vibrometry
    Abe, M
    Fujino, Y
    Kaito, K
    PROCEEDINGS OF IMAC-XIX: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, 2001, 4359 : 704 - 709
  • [16] Dynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative Study
    Ivanovic, Aleksandra
    Cheng, Jeffrey Tao
    Schmeltz, Margaux
    Wimmer, Wilhelm
    Schlepuetz, Christian M.
    Remenschneider, Aaron K.
    Bonnin, Anne
    Anschuetz, Lukas
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2025, 26 (01): : 63 - 75
  • [17] Laser-Doppler vibrometry with variable GHz heterodyne carrier via frequency-offset lock
    Kowarsch, Robert
    Rembe, Christian
    INTERFEROMETRY XIX, 2018, 10749
  • [18] Dynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative StudyDynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative StudyA. Ivanovic et al.
    Aleksandra Ivanovic
    Jeffrey Tao Cheng
    Margaux Schmeltz
    Wilhelm Wimmer
    Christian M. Schlepuetz
    Aaron K. Remenschneider
    Anne Bonnin
    Lukas Anschuetz
    Journal of the Association for Research in Otolaryngology, 2025, 26 (1) : 63 - 75
  • [19] BLOODFLOW MEASUREMENT USING THE LASER-DOPPLER TECHNIQUE
    NILSSON, A
    TENLAND, T
    OBERG, A
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (01) : N18 - N19
  • [20] THE DYNAMICS OF MICRO SLIDERS USING LASER DOPPLER VIBROMETRY
    BRIGGS, CA
    TALKE, FE
    IEEE TRANSACTIONS ON MAGNETICS, 1990, 26 (05) : 2442 - 2444