Contactless Vibrational Analysis of Transparent Hydrogel Structures Using Laser-Doppler Vibrometry

被引:11
|
作者
Schwarz, S. [1 ,2 ,3 ]
Hartmann, B. [1 ,3 ]
Sauer, J. [4 ]
Burgkart, R. [5 ]
Sudhop, S. [1 ,3 ]
Rixen, D. J. [2 ]
Clausen-Schaumann, H. [1 ,3 ]
机构
[1] Munich Univ Appl Sci, Ctr Appl Tissue Engn & Regenerat Med, Lothstr 34, D-80335 Munich, Germany
[2] Tech Univ Munich, Dept Mech Engn, D-85748 Garching, Germany
[3] Ludwig Maximilians Univ Munchen, Ctr NanoSci, D-80799 Munich, Germany
[4] Polytec GmbH, D-76337 Waldbronn, Germany
[5] Tech Univ Munich, Klin & Poliklin Orthopadie & Sportorthopadie, D-81675 Munich, Germany
关键词
LDV; Mechanical properties; Biomaterials; Atomic force microscopy (AFM); Compression testing; MECHANICAL-PROPERTIES; ARTICULAR-CARTILAGE; MIGRATION; GROWTH; MORPHOGENESIS; ELASTICITY; BEHAVIOR; CELLS; WATER;
D O I
10.1007/s11340-020-00626-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background Investigating the mechanical properties of biological and biocompatible hydrogels is important in tissue engineering and biofabrication. Atomic force microscopy (AFM) and compression testing are routinely used to determine mechanical properties of tissue and tissue constructs. However, these techniques are slow and require mechanical contact with the sample, rendering in situ measurements difficult. Objective We therefore aim at a fast and contactless method for determining the mechanical properties of biological hydrogels and investigate if an optical method, like Laser-Doppler vibrometry (LDV), can accomplish this task. Methods LDV is a fast contactless method for mechanical analysis. Nonetheless, LDV setups operating in the visible range of the optical spectrum are difficult to use for transparent materials, such as biological hydrogels, because LDV relies on reflected or back-scattered light from the sample. We therefore use a near-infrared (NIR) scanning LDV to determine the vibration spectra of cylindrical gelatin discs of different gelatin concentration and compare the results to AFM data and unconfined compression testing. Results We show that the gelatin test structures can be analyzed, using a NIR LDV, and the Young's moduli can be deduced from the resonance frequencies of the first normal (0,1) mode of these structures. As expected, the frequency of this mode increases with the square root of the Young's modulus and the damping constant increases exponentially with gelatin concentration, which underpins the validity of our approach. Conclusions Our results demonstrate that NIR wavelengths are suitable for a fast, contactless vibrational analysis of transparent hydrogel structures.
引用
收藏
页码:1067 / 1078
页数:12
相关论文
共 50 条
  • [1] Contactless Vibrational Analysis of Transparent Hydrogel Structures Using Laser-Doppler Vibrometry
    S. Schwarz
    B. Hartmann
    J. Sauer
    R. Burgkart
    S. Sudhop
    D. J. Rixen
    H. Clausen-Schaumann
    Experimental Mechanics, 2020, 60 : 1067 - 1078
  • [2] Fast characterization of silicon membrane structures by laser-doppler vibrometry
    Gerbach, Ronny
    Ebert, Matthias
    Bagdahn, Joerg
    MICROELECTROMECHANICAL SYSTEMS - MATERIALS AND DEVICES, 2008, 1052 : 21 - 28
  • [3] THE APPLICATION OF SCANNING LASER-DOPPLER VIBROMETRY IN AEROENGINE DEVELOPMENT
    HANCOX, J
    STAPLES, BC
    PARKER, RJ
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 1995, 209 (G1) : 35 - 42
  • [4] Differential laser-Doppler vibrometry for airborne vibration measurements with drones
    Schewe M.
    Ismail M.A.A.
    Rembe C.
    Technisches Messen, 2021, 88 (S1): : S42 - S47
  • [5] Applications of laser-Doppler vibrometry during MEMS device qualification
    De Coster, Jeroen
    Sangameswaran, Sandeep
    De Wolf, Ingrid
    OPTICAL MEASUREMENT TECHNIQUES FOR STRUCTURES AND SYSTEMS, 2009, : 141 - 150
  • [6] A Normalized Model of a Microelectromechanical Relay Calibrated by Laser-Doppler Vibrometry
    Marvin, Jessica
    Jang, Michael
    Contreras, Daniel
    Spencer, Matthew
    MICROMACHINES, 2022, 13 (10)
  • [7] CONTOUR MAPPING OF PRECISION BALL DEFECTS WITH LASER-DOPPLER VIBROMETRY
    CHONG, AKF
    LIEU, DK
    PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1993, 15 (03): : 166 - 172
  • [8] Investigation of the mechanics of type III stapes colurnella tyrnpanoplasty using laser-doppler vibrometry
    Chien, Wade
    Rosowski, John J.
    Merchant, Saumil N.
    OTOLOGY & NEUROTOLOGY, 2007, 28 (06) : 782 - 787
  • [9] TYMPANIC MEMBRANE VIBRATION ANALYSIS BY LASER-DOPPLER VIBROMETRY IN EXPERIMENTAL FIXATION OF THE STAPES FOOTPLATE
    STASCHE, N
    BAKER, A
    FOTH, HJ
    HUTHOFF, C
    HORMANN, K
    LARYNGO-RHINO-OTOLOGIE, 1994, 73 (07) : 353 - 357
  • [10] CONTACTLESS MEASUREMENT OF YARN SPEED WITH A LASER-DOPPLER VELOCITY METER
    DUBBELDA.GC
    JOURNAL OF THE TEXTILE INSTITUTE, 1974, 65 (09) : 483 - 487