Blood pressure estimation based on heart sound signals

被引:1
|
作者
Cheng Xie-Feng [1 ]
Dai Shi-Cheng [1 ]
Zhao Peng-Jun [2 ]
机构
[1] Nanjing Univ Posts & Telecommun, Coll Elect & Opt Engn, Nanjing 210023, Peoples R China
[2] Shanghai Jiao Tong Univ, Xin Hua Hosp, Pediat Cardiol, Sch Med, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
blood pressure; aortic valve heart sound; peak detection; kurtosis;
D O I
10.7498/aps.69.20200254
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Cardiovascular disease, especially hypertension, has become one of the biggest killers of human life and health. Therefore, early detection and prevention of cardiovascular diseases are of great significance for people's health. In this paper, we explore the relationship between aortic valve heart sound signal and blood pressure, and propose a method of non-invasively estimating blood pressure based on heart sound signals. First, according to the relationship between blood pressure and the heart sound signal, both the time interval between the peak point of the first heart sound and that of the second heart sound and the kurtosis of the second heart sound are extracted as features. Then the time interval between the first heart sound and the second heart sound, and the kurtosis of the second heart sound are linearly fitted to the measured blood pressure. Finally, according to the linear relationship between heart sound and blood pressure, a blood pressure evaluation formula based on the heart sound is established. The experimental results show that the time interval between the peak point of the first heart sound and that of the second heart sound, and the kurtosis of the second heart sound can be used as the characteristic parameters of blood pressure evaluation, which have a good linear relationship with blood pressure. The goodness of fit is 0.801 and 0.765, separately. The average error between the blood pressure calculated from the blood pressure calculation formula and the blood pressure measured by a commercial electronic sphygmomanometer is less than 5 mmHg, and the standard deviation is less than 8 mmHg. For hypertensive patients, the time interval between the peak point of the first heart sound and the second heart sound is shortened, and the kurtosis of the second heart sound is increased, which is a typical feature of heart sounds in patients with hypertension. Compared with the traditional blood pressure calculation method, the blood pressure assessment method proposed in this paper only needs to collect heart sound signals to effectively assess the blood pressure. The method is convenient to operate and can be used for continuously monitoring the blood pressure, and is especially suitable for monitoring the blood pressures of infants, disabled patients with limbs, and disabilities in certain medical environments.
引用
收藏
页数:10
相关论文
共 17 条
  • [1] [Anonymous], 2014, THESIS
  • [2] [Anonymous], 2015, NCD mortality and morbidity
  • [3] NONINVASIVE DETERMINATION OF SYSTOLIC BLOOD-PRESSURE BY HEART-SOUND PATTERN-ANALYSIS
    BARTELS, A
    HARDER, D
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 (03): : 249 - 256
  • [4] Arterial pressure changes monitoring with a new precordial noninvasive sensor
    Bombardini, Tonino
    Gemignani, Vincenzo
    Bianchini, Elisabetta
    Venneri, Lucia
    Petersen, Christina
    Pasanisi, Emilio
    Pratali, Lorenza
    Pianelli, Mascia
    Faita, Francesco
    Giannoni, Massimo
    Arpesella, Giorgio
    Picano, Eugenio
    [J]. CARDIOVASCULAR ULTRASOUND, 2008, 6 (1)
  • [5] Cai R P, 2012, SCI MONTHLY, V507, P236
  • [6] Ding XR, 2016, IEEE J BIOMED HEALTH, V20, P1
  • [7] Digital signal processing of the phonocardiogram: Review of the most recent advancements
    Durand, LG
    Pibarot, P
    [J]. CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1995, 23 (3-4) : 163 - 219
  • [8] A METHOD USING INDUCED WAVES TO STUDY PRESSURE PROPAGATION IN HUMAN ARTERIES
    LANDOWNE, M
    [J]. CIRCULATION RESEARCH, 1957, 5 (06) : 594 - 601
  • [9] Correlation of blood pressure and the ratio of S1 to S2 as measured by esophageal stethoscope and wireless bluetooth transmission
    Lim, Kyoung Hoon
    Shin, Young Duck
    Park, Sang Hi
    Bae, Jin Ho
    Lee, Hong Jae
    Kim, Seon Jung
    Shin, Ji Yun
    Choi, Young Jin
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2013, 29 (04) : 1023 - 1027
  • [10] Performance of an open-source heart sound segmentation algorithm on eight independent databases
    Liu, Chengyu
    Springer, David
    Clifford, Gari D.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2017, 38 (08) : 1730 - 1745