NIR- and FRET-Based Sensing of Cu2+ and S2- in Physiological Conditions and in Live Cells

被引:230
作者
Kar, Chirantan [1 ]
Adhikari, Manab Deb [2 ]
Ramesh, Aiyagari [2 ]
Das, Gopal [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Gauhati 781039, Assam, India
[2] Indian Inst Technol, Dept Biotechnol, Gauhati 781039, Assam, India
关键词
RESONANCE ENERGY-TRANSFER; RATIOMETRIC FLUORESCENCE DETECTION; COPPER(II) COMPLEX; NEURODEGENERATIVE DISEASES; SELECTIVE RECOGNITION; MOLECULAR-MECHANISMS; BACTERIAL-INFECTION; TRIPODAL RECEPTOR; HYDROGEN-SULFIDE; AQUEOUS-SOLUTION;
D O I
10.1021/ic301872q
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
We have synthesized a new indole functionalized rhodamine derivative L-1 which specifically binds to Cu2+ in the presence of large excess of other competing ions with visually observable changes in their electronic and fluorescence spectral behavior. These spectral changes are significant enough in the NIR and visible region of the spectrum and thus enable naked eye detection. The receptor, L-1, could be employed as a resonance energy transfer (RET) based sensor for detection of Cu2+ based on the process involving the donor indole and the acceptor Cu2+ bound xanthene fragment. Studies reveal that L-1-Cu complex is selectively and fully reversible in presence of sulfide anions. Further, fluorescence microscopic studies confirmed that the reagent L-1 could also be used as an imaging probe for detection of uptake of these ions in HeLa cells.
引用
收藏
页码:743 / 752
页数:10
相关论文
共 50 条
  • [31] Simultaneous bioimaging recognition of Al3+ and Cu2+ in living-cell, and further detection of F- and S2- by a simple fluorogenic benzimidazole-based chemosensor
    Liu, Haiyang
    Zhang, Bibo
    Tan, Chunyan
    Liu, Feng
    Cao, Jiakun
    Tan, Ying
    Jiang, Yuyang
    TALANTA, 2016, 161 : 309 - 319
  • [32] Benzodithieno-imidazole based π-conjugated fluorescent polymer probe for selective sensing of Cu2+
    Giri, Dipanjan
    Patra, Sanjib K.
    RSC ADVANCES, 2015, 5 (96) : 79011 - 79021
  • [33] A FRET-based carbon dot-MnO2 nanosheet architecture for glutathione sensing in human whole blood samples
    Wang, Yuhui
    Jiang, Kai
    Zhu, Jiali
    Zhang, Ling
    Lin, Hengwei
    CHEMICAL COMMUNICATIONS, 2015, 51 (64) : 12748 - 12751
  • [34] A perylene diimide-based near-IR ratiometric sensor for detection of Cu2+ ions: ensemble for discrimination of CN- and S2- ions
    Sharma, Poonam
    Singh, Prabhpreet
    ANALYTICAL METHODS, 2020, 12 (06) : 758 - 767
  • [35] A resumable two-photon fluorescent probe for Cu2+ and S2- based on magnetic silica core-shell Fe3O4@SiO2 nanoparticles and its application in bioimaging
    Jiang, Huie
    Liu, Yan
    Luo, Weifang
    Wang, Yujiao
    Tang, Xiaoliang
    Dou, Wei
    Cui, Yumei
    Liu, Weisheng
    ANALYTICA CHIMICA ACTA, 2018, 1014 : 91 - 99
  • [36] Catching S2- and Cu2+ by a highly sensitive and efficient salamo-like fluorescence-ultraviolet dual channel chemosensor
    Mu, Hao-Ran
    Yu, Meng
    Wang, Lan
    Zhang, Yang
    Ding, Yu-Jie
    PHOSPHORUS SULFUR AND SILICON AND THE RELATED ELEMENTS, 2020, 195 (09) : 730 - 739
  • [37] Study on the photochromism, photochromic fluorescence switch, fluorescent and colorimetric sensing for Cu2+ of naphthopyran-diaminomaleonitrile dyad and recognition Cu2+ in living cells
    Zhang, Heyang
    Zhong, Tianyuan
    Jiang, Nan
    Zhang, Zhuo
    Gong, Xue
    Wang, Guang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 233
  • [38] Design of a FRET-based fluorescent probe for the reversible detection of SO2and formaldehyde in living cells and mice
    Gao, Wenjie
    Ma, Yanyan
    Lin, Weiying
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (32) : 13654 - 13658
  • [39] Mitochondria-targeted and FRET-based fluorescent probe for the imaging of endogenous SO2 in living cells
    Sun, Yaru
    Wang, Yan
    Lu, Yaru
    Kong, Xiuqi
    Wei, Hua
    Chen, Qingxian
    Yan, Mei
    Dong, Baoli
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 265
  • [40] A highly selective fluorescent sensor based on calix[4]arene appended benzothiazole units for Cu2+, S2- and HSO4- ions in aqueous solution
    Erdemir, Serkan
    Tabakci, Begum
    Tabakci, Mustafa
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 228 : 109 - 116