Three-Phase Fault Detection During Power Swing by Transient Monitor

被引:76
作者
Khodaparast, Jalal [1 ]
Khederzadeh, Mojtaba [1 ]
机构
[1] Shahid Beheshti Univ, Fac Elect & Comp Engn, Tehran 1658953571, Iran
关键词
Distance relay; dynamic phasor; power swing blocking; three-phase fault; transient monitor; INSTANTANEOUS OSCILLATING PHASOR; SYMMETRICAL FAULT; DISTANCE RELAY; BLOCKING; SCHEME;
D O I
10.1109/TPWRS.2014.2365511
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Distance relays are immune to inadvertent operation during power swings by a block known as "power swing blocking (PSB)". Its main function is discriminating faults from power swings. However, if a fault occurs during a power swing, PSB should be de-blocked and let the distance relay to operate normally and clear the fault accordingly. Meanwhile, discrimination of a three-phase fault from a power swing is the most difficult task due to their likelihood. This paper proposes a new method to overcome this issue by monitoring the transient period established in the process of current dynamic phasor estimation. In this regard, transient monitor (TM) index, which is the difference between the estimated current samples regenerated from the calculated dynamic phasors and the actual sample values, is used to distinguish the fault from the power swing. Fourier-Taylor transformation is applied to estimate the dynamic phasor of the current signal. Simulation results verify the inherent potential of the proposed method to overcome the issue.
引用
收藏
页码:2558 / 2565
页数:8
相关论文
共 25 条
[1]   Dynamic Phasor and Frequency Estimates Through Maximally Flat Differentiators [J].
Angel Platas-Garza, Miguel ;
Antonio de la O Serna, Jose .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (07) :1803-1811
[2]  
[Anonymous], C371182005 IEEE
[3]  
Apostolov AP, 2004, 2004 IEEE PES POWER SYSTEMS CONFERENCE & EXPOSITION, VOLS 1 - 3, P592
[4]  
Blumschein J., 2014, J. Power Energy Eng, V2, P694, DOI [10.4236/jpee.2014.24093, DOI 10.4236/JPEE.2014.24093]
[5]   Distance relay with out-of-step-blocking function using wavelet transform [J].
Brahma, Sukumar M. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (03) :1360-1366
[6]   Phasor estimation from phasorlets [J].
de la O Serna, JA .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (01) :134-143
[7]   Instantaneous Oscillating Phasor Estimates With TaylorK-Kalman Filters [J].
de la O Serna, Jose Antonio ;
Rodriguez-Maldonado, Johnny .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (04) :2336-2344
[8]  
Fu L., 2006, P IEEE POW ENG SOC G, P1
[9]  
IEEE PSRC WG D6, 2005, POWER SWING OUT STEP
[10]   Synchrophasor-Assisted Zone 3 Operation [J].
Kundu, Pratim ;
Pradhan, Ashok Kumar .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (02) :660-667