Chronic leak detection for single and multiphase flow: A critical review on onshore and offshore subsea and arctic conditions

被引:40
作者
Behari, Niresh [1 ,2 ]
Sheriff, M. Ziyan [3 ,4 ]
Rahman, Mohammad Azizur [5 ]
Nounou, Mohamed [4 ]
Hassan, Ibrahim [6 ]
Nounou, Hazem [7 ]
机构
[1] Mem Univ Newfoundland, St John, NF, Canada
[2] Royal Dutch Shell, Amsterdam, Netherlands
[3] Texas A&M Univ, Artie McFerrin Dept Chem Engn, College Stn, TX 77843 USA
[4] Texas A&M Univ Qatar, Chem Engn Program, Doha, Qatar
[5] Texas A&M Univ Qatar, Petr Engn Program, Doha, Qatar
[6] Texas A&M Univ Qatar, Mech Engn Program, Doha, Qatar
[7] Texas A&M Univ Qatar, Elect Engn Program, Doha, Qatar
关键词
Pipeline leak detection; Multiphase flow; Chronic leaks; Subsea and arctic flow monitoring; Fiber optic sensing; Leak detection and localization technology; FLUID DYNAMIC SIMULATION; NEGATIVE-PRESSURE WAVE; DETECTION SYSTEMS; EXPERT-SYSTEM; PIPELINE; OIL; COMPOSITE; ALGORITHM; LOCATION; MODEL;
D O I
10.1016/j.jngse.2020.103460
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Leak detection in pipelines has been a prevalent issue for several decades. Pipeline leaks from sources such as small cracks and pinholes are termed chronic leaks, as they have the potential of going unnoticed for long time periods, causing both economic losses and environmental damage. Literature lacks a comprehensive review of chronic leaks, especially under subsea or arctic conditions. Therefore, a primary objective of this work was the critical analysis of the current state of leak detection technology, especially under these conditions. A summary of critical findings from both experimental and field studies is included. A secondary goal was to determine the leak detection accuracy, resource level requirements, and risk of installation and operation for various techniques. The analysis shows medium to large scale leaks between 3 and 10 mm can be detected using dynamic pressure wave monitoring for single phase flow, whereas sequential probability ratio testing (SPRT) using real time transient monitoring (RTTM) can be used to monitor leaks for multiphase flow even in shallow water conditions and along elevated pipeline networks. Vacuum annulus monitoring arrangements can be utilized in order to detect chronic leaks, but are limited in their application due to weight and difficulty of pipeline installation. Additionally, distributed temperature sensing (DTS) and distributed acoustic sensing (DAS) leak detection using fiber optic cables (FOC) was found to be resource intensive and have higher installation cost and operational risks due to unknown equipment reliability and location or sealing of the FOC on the pipeline structure. SPRT using RTTM have comparable accuracy to DTS or DAS leak detection and can be retrofitted to existing pipeline networks. However, more pilot studies utilizing FOC for subsea and arctic conditions need to be developed and examined. Leak detection using new pipeline construction materials such as reinforced thermoplastics (RTP) also warrant further research due to a current lack of reliable technology for these materials.
引用
收藏
页数:18
相关论文
共 106 条
  • [21] Computational fluid dynamic simulation of small leaks in water pipelines for direct leak pressure transduction
    Ben-Mansour, R.
    Habib, M. A.
    Khalifa, A.
    Youcef-Toumi, K.
    Chatzigeorgiou, D.
    [J]. COMPUTERS & FLUIDS, 2012, 57 : 110 - 123
  • [22] Bennett C.L., 1995, INT S OPT SCI ENG IN
  • [23] Best Management Practice, 2017, US REINF COMP PIP NO
  • [24] Beushausen R., 2004, PROCEECGINGS BIENNIA, P2285
  • [25] bin Md Akib Afifi, 2011, 2011 Proceedings of IEEE 7th International Colloquium on Signal Processing & its Applications (CSPA 2011), P103, DOI 10.1109/CSPA.2011.5759852
  • [26] Bryce PW, 2002, OIL GAS J, V100, P53
  • [27] Chunlong Ma, 2010, 2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering (CMCE 2010), P306, DOI 10.1109/CMCE.2010.5609975
  • [28] Chunyuan Wang, 2018, IOP Conference Series: Materials Science and Engineering, V394, DOI 10.1088/1757-899X/394/4/042077
  • [29] CFD modeling of plume and free surface behavior resulting from a sub-sea gas release
    Cloete, Schalk
    Olsen, Jan Erik
    Skjetne, Paal
    [J]. APPLIED OCEAN RESEARCH, 2009, 31 (03) : 220 - 225
  • [30] Standing wave difference method for leak detection in pipeline systems
    Covas, D
    Ramos, H
    de Almeida, AB
    [J]. JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2005, 131 (12): : 1106 - 1116