Design and implementation of a 150 GHz single-channel millimeter wave interferometer on Joint TEXT tokamak

被引:3
作者
Feng, X. D. [1 ]
Zhuang, G. [1 ]
Yang, Z. J. [1 ]
Gao, L. [1 ]
Hu, X. W. [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
关键词
D O I
10.1063/1.4802690
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A simple, single-channel millimeter-wave interferometer system has been designed, fabricated, and installed on the J-TEXT tokamak. For the plasma density anticipated on J-TEXT, a solid-state source operating at 150 GHz has been chosen to minimize errors due to both vibration along the beam path and refraction in the plasma. The new aspect of the interferometer design is to use a subharmonic mixer for detection with a frequency doubled 150 GHz source. It employs a single source which is bias-tuned and modulated with a sawtooth wave form up to 100 kHz in order to generate the intermediate frequency. The 12.5 GHz voltage-controlled oscillator is multiplied to 75 GHz before a final doubler raises it to 150 GHz. A portion of the 75 GHZ power is used for the local oscillator (LO) and is directly connected to the LO input of the subharmonic mixer. The phase is evaluated by a digital phase comparator using a software-based algorithm. Detection noise limits the minimum resolvable phase change with the interferometer to +/- 0.05 fringe, which corresponds to an averaged electron density change along the chord of +/- 1.1 x 10(17) m(-2). The maximum measurable electron density is expected to be similar to 9 x 10(19) m(-3). A comparison of preliminary results from the millimeter wave interferometer with that from the far-infrared hydrogen cyanide laser (wavelength of 337 mu m) interferometer shows good agreement during the pulse flat-top period. The millimeter wave interferometer system will be used as a part of the density feedback control system in the future. (C) 2013 AIP Publishing LLC. [http://dx.doi.org/10.1063/1.4802690]
引用
收藏
页数:4
相关论文
共 7 条
[1]   Multichannel interferometer system for the helically symmetric experiment [J].
Brower, DL ;
Deng, C ;
Ding, WX ;
Anderson, DT ;
Mason, W .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) :1081-1084
[2]   The 7-channel FIR HCN interferometer on J-TEXT tokamak [J].
Chen, W. ;
Gao, L. ;
Chen, J. ;
Li, Q. ;
Wang, Z. J. ;
Zhuang, G. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[3]   1-MILLIMETER WAVE INTERFEROMETER FOR THE MEASUREMENT OF LINE INTEGRAL ELECTRON-DENSITY ON TFTR [J].
EFTHIMION, PC ;
TAYLOR, G ;
ERNST, W ;
GOLDMAN, M ;
MCCARTHY, M ;
ANDERSON, H ;
LUHMANN, NC .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05) :908-910
[4]  
Hutchinson I. H., 2002, PRINCIPLES PLASMA DI
[5]   Design and implementation of a multichannel millimeter wave interferometer for the Compact Toroidal Hybrid experiment [J].
Miller, M. C. ;
Hanson, J. D. ;
Hartwell, G. J. ;
Knowlton, S. F. ;
Maurer, D. A. ;
Stevenson, B. A. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10)
[6]   Design and operation of a low cost, reliable millimeter-wave interferometer [J].
Porte, L ;
Rettig, CL ;
Peebles, WA ;
Ngyuen, X .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :1082-1084
[7]   The reconstruction and research progress of the TEXT-U tokamak in China [J].
Zhuang, G. ;
Pan, Y. ;
Hu, X. W. ;
Wang, Z. J. ;
Ding, Y. H. ;
Zhang, M. ;
Gao, L. ;
Zhang, X. Q. ;
Yang, Z. J. ;
Yu, K. X. ;
Gentle, K. W. ;
Huang, H. .
NUCLEAR FUSION, 2011, 51 (09)