Determination of 27 Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry

被引:14
作者
King, Thomas [1 ]
Sheridan, Robert [1 ]
机构
[1] New York State Dept Agr & Markets Food Lab, 1220 Washington Ave, Albany, NY 12235 USA
关键词
RICE BRAN; CATTLE; COPPER; LEAD; INTOXICATION; TOXICITY; TISSUES;
D O I
10.5740/jaoacint.18-0198
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed to determine 27 elements (aluminum, arsenic, boron, cadmium, calcium, chromium, cobalt, copper, iron, lead, magnesium, manganese, mercury, molybdenum, nickel, phosphorus, potassium, selenium, sodium, sulfur, vanadium, zinc, antimony, uranium, beryllium, thallium, and thorium) in animal feeds and pet foods using closed vessel microwave digestion and inductively coupled plasma-mass spectrometry. These elements can adversely affect animal health when amounts become excessive or deficient in food. For potentially toxic elements, the target LOQ was determined to be 1/10 the lowest maximum tolerable level (MTL) for the most sensitive animal species. For nutritionally essential elements, the target LOQ was determined to be 1/10 the concentration that would be considered deficient in feed if that level is lower than 1/10 the lowest MTL. The targeted high end of the quantitation range was selected as twice the highest MTL. A single-laboratory validation (SLV) was performed to determine the accuracy and precision of the method, and the results were evaluated with respect to predetermined performance characteristics. The test materials used in the SLV included two National Institute of Standards and Technology certified reference materials, two Association of American Feed Control Officials (AAFCO) check samples, and one in-house previously analyzed feed sample. The concentrations of each element determined were the result of spiked analyte, incurred analyte, or a combination of spiked and incurred analyte. All samples were analyzed seven times on different days at 2 x LOQ and at the midrange concentration. For most data, the results of the SLV met or exceeded the criteria for accuracy and repeatability. For accuracy, K at the midrange level had a mean recovery of 95%, which is just below the low preferred accuracy threshold of 97%. For repeatability, all the 2 x LOQ CVr values were below the preferred values. Be, Cr, Ni, Na, Mn, and S all had midrange CVr values exceeding the preferred values. Be had the highest midrange CVr value of 9.93. Eight AAFCO check samples were also analyzed to determine the method's accuracy and repeatability for elements at the manufacturer's claimed levels. For accuracy, all results had z-scores <1.5. For repeatability, three CVr values from two AAFCO check samples were greater than the preferred limits.
引用
收藏
页码:434 / 444
页数:11
相关论文
共 50 条
  • [41] Determination of Pb, Cr, Cd, and As in Aluminum-Plastic Packaging Materials via Inductively Coupled Plasma-Mass Spectrometry with Microwave Digestion
    Mi Hai-peng
    Zhu Hong-ming
    Li Gen-rong
    Yu Xiang
    Ma Bing-bing
    Zhou Xi-lin
    Wang Ya-sen
    Su Zhong-hua
    Deng Xiong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (02) : 646 - 650
  • [42] Comparison of tunable bandpass reaction cell inductively coupled plasma mass spectrometry with conventional inductively coupled plasma mass spectrometry for the determination of heavy metals in whole blood and urine
    Nixon, DE
    Neubauer, KR
    Eckdahl, SJ
    Butz, JA
    Burritt, MF
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (09) : 1377 - 1387
  • [43] Determination of trace elements in biological samples by inductively coupled plasma mass spectrometry with tetramethylammonium hydroxide solubilization at room temperature
    Batista, Bruno Lemos
    Grotto, Denise
    Rodrigues, Jairo Lisboa
    de Oliveira Souza, Vanessa Cristina
    Barbosa, Fernando, Jr.
    ANALYTICA CHIMICA ACTA, 2009, 646 (1-2) : 23 - 29
  • [44] Determination of Trace Elements in Mushrooms by Inductively Coupled Plasma - Mass Spectrometry (ICP-MS): Characterization of the Health Risk
    Dimitrijevic, Marija
    Nikolic, Jelena
    Mitic, Violeta
    Stankov Jovanovic, Vesna
    Miladinovic, Dragoljub
    ANALYTICAL LETTERS, 2023, 56 (13) : 2201 - 2214
  • [45] Lead determination in whole blood by laser ablation coupled with inductively coupled plasma mass spectrometry
    Hsieh, Hui-Fang
    Chang, Wei-Shan
    Hsieh, Yi-Kong
    Wang, Chu-Fang
    TALANTA, 2009, 79 (02) : 183 - 188
  • [46] Method validation for direct determination of some trace and toxic elements in soft drinks by inductively coupled plasma mass spectrometry
    Ghuniem, Mahmoud M.
    Khorshed, Mona A.
    Souaya, Eglal R.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2019, 99 (06) : 515 - 540
  • [47] Elemental Profiling of Smokeless Tobacco Samples Using Inductively Coupled Plasma-Mass Spectrometry, their Chemometric Analysis and Assessment of Health Hazards
    Alhazmi, Hassan A.
    Ahsan, Waquar
    Attafi, Ibraheem M.
    Khalid, Asaad
    Abdelwahab, Siddig I.
    Al Bratty, Mohammad
    Sultana, Shahnaz
    PHARMACOGNOSY MAGAZINE, 2018, 14 (58) : 587 - 596
  • [48] Evaluation of ultrasound-assisted extraction as sample pre-treatment for quantitative determination of rare earth elements in marine biological tissues by inductively coupled plasma-mass spectrometry
    Costas, M.
    Lavilla, I.
    Gil, S.
    Pena, F.
    de la Calle, I.
    Cabaleiro, N.
    Bendicho, C.
    ANALYTICA CHIMICA ACTA, 2010, 679 (1-2) : 49 - 55
  • [49] Sequential Analysis of Trace Elements in a Micro Volume Urine Sample Using Inductively Coupled Plasma Mass Spectrometry
    Laur, Nico
    Kaiser, Lars
    Deigner, Hans-Peter
    Kinscherf, Ralf
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [50] Rapid analysis of titanium dioxide nanoparticles in sunscreens using single particle inductively coupled plasma-mass spectrometry
    Dan, Yongbo
    Shi, Honglan
    Stephan, Chady
    Liang, Xinhua
    MICROCHEMICAL JOURNAL, 2015, 122 : 119 - 126