Determination of 27 Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry

被引:14
作者
King, Thomas [1 ]
Sheridan, Robert [1 ]
机构
[1] New York State Dept Agr & Markets Food Lab, 1220 Washington Ave, Albany, NY 12235 USA
关键词
RICE BRAN; CATTLE; COPPER; LEAD; INTOXICATION; TOXICITY; TISSUES;
D O I
10.5740/jaoacint.18-0198
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed to determine 27 elements (aluminum, arsenic, boron, cadmium, calcium, chromium, cobalt, copper, iron, lead, magnesium, manganese, mercury, molybdenum, nickel, phosphorus, potassium, selenium, sodium, sulfur, vanadium, zinc, antimony, uranium, beryllium, thallium, and thorium) in animal feeds and pet foods using closed vessel microwave digestion and inductively coupled plasma-mass spectrometry. These elements can adversely affect animal health when amounts become excessive or deficient in food. For potentially toxic elements, the target LOQ was determined to be 1/10 the lowest maximum tolerable level (MTL) for the most sensitive animal species. For nutritionally essential elements, the target LOQ was determined to be 1/10 the concentration that would be considered deficient in feed if that level is lower than 1/10 the lowest MTL. The targeted high end of the quantitation range was selected as twice the highest MTL. A single-laboratory validation (SLV) was performed to determine the accuracy and precision of the method, and the results were evaluated with respect to predetermined performance characteristics. The test materials used in the SLV included two National Institute of Standards and Technology certified reference materials, two Association of American Feed Control Officials (AAFCO) check samples, and one in-house previously analyzed feed sample. The concentrations of each element determined were the result of spiked analyte, incurred analyte, or a combination of spiked and incurred analyte. All samples were analyzed seven times on different days at 2 x LOQ and at the midrange concentration. For most data, the results of the SLV met or exceeded the criteria for accuracy and repeatability. For accuracy, K at the midrange level had a mean recovery of 95%, which is just below the low preferred accuracy threshold of 97%. For repeatability, all the 2 x LOQ CVr values were below the preferred values. Be, Cr, Ni, Na, Mn, and S all had midrange CVr values exceeding the preferred values. Be had the highest midrange CVr value of 9.93. Eight AAFCO check samples were also analyzed to determine the method's accuracy and repeatability for elements at the manufacturer's claimed levels. For accuracy, all results had z-scores <1.5. For repeatability, three CVr values from two AAFCO check samples were greater than the preferred limits.
引用
收藏
页码:434 / 444
页数:11
相关论文
共 50 条
  • [31] Rapid determination of trace elements in serum of hepatocellular carcinoma patients by inductively coupled plasma tandem mass spectrometry
    Fu, Liang
    Xie, Hualin
    Huang, Jianhua
    Chen, Lin
    ANALYTICA CHIMICA ACTA, 2020, 1112 : 1 - 7
  • [32] Determination of Toxic Elements in Nuts by Inductively Coupled Plasma Mass Spectrometry after Microwave-Induced Combustion
    Muller, Aline L. H.
    Muller, Cristiano C.
    Lyra, Fernanda
    Mello, Paola A.
    Mesko, Marcia F.
    Muller, Edson I.
    Flores, Erico M. M.
    FOOD ANALYTICAL METHODS, 2013, 6 (01) : 258 - 264
  • [33] Portable x-ray fluorescence for assessing trace elements in rice and rice products: Comparison with inductively coupled plasma-mass spectrometry
    Fleming, David E. B.
    Foran, Kelly A.
    Kim, Jong Sung
    Guernsey, Judy R.
    APPLIED RADIATION AND ISOTOPES, 2015, 104 : 217 - 223
  • [34] Determination of Chromium Based on Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Wei, Xing
    Zhou, Jing-Jing
    Liu, Jin-Hui
    Chen, Ming-Li
    Wang, Jian-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (03) : 432 - 439
  • [35] Minireview: Advances in Germanium Isotope Analysis by Multiple Collector-Inductively Coupled Plasma-Mass Spectrometry
    Meng, Yu-Miao
    Hu, Rui-Zhong
    ANALYTICAL LETTERS, 2018, 51 (05) : 627 - 647
  • [36] Quantitative dried blood spot analysis for metallodrugs by laser ablation inductively coupled plasma-mass spectrometry
    Kroeger, Sabrina
    Sperling, Michael
    Karst, Uwe
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2019, 51 : 50 - 56
  • [37] Determination of the total and extractable mass fractions of cadmium and lead in mineral feed by using isotope dilution inductively coupled plasma mass spectrometry
    Vassileva, Emilia
    Hoenig, Michel
    ANALYTICA CHIMICA ACTA, 2011, 701 (01) : 37 - 44
  • [38] A rugged and transferable method for determining blood cadmium, mercury, and lead with inductively coupled plasma-mass spectrometry
    McShane, William J.
    Pappas, R. Steven
    Wilson-McElprang, Veronica
    Paschal, Dan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (06) : 638 - 644
  • [39] Assessment of trace elements in human brain using inductively coupled plasma mass spectrometry
    Krebs, Nikolaus
    Langkammer, Christian
    Goessler, Walter
    Ropele, Stefan
    Fazekas, Franz
    Yen, Kathrin
    Scheurer, Eva
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2014, 28 (01) : 1 - 7
  • [40] Trace elemental imaging of coralline hydroxyapatite by laser-ablation inductively coupled plasma-mass spectroscopy
    Chou, J.
    Austin, C.
    Doble, P.
    Ben-Nissan, B.
    Milthorpe, B.