Determination of 27 Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry

被引:14
作者
King, Thomas [1 ]
Sheridan, Robert [1 ]
机构
[1] New York State Dept Agr & Markets Food Lab, 1220 Washington Ave, Albany, NY 12235 USA
关键词
RICE BRAN; CATTLE; COPPER; LEAD; INTOXICATION; TOXICITY; TISSUES;
D O I
10.5740/jaoacint.18-0198
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed to determine 27 elements (aluminum, arsenic, boron, cadmium, calcium, chromium, cobalt, copper, iron, lead, magnesium, manganese, mercury, molybdenum, nickel, phosphorus, potassium, selenium, sodium, sulfur, vanadium, zinc, antimony, uranium, beryllium, thallium, and thorium) in animal feeds and pet foods using closed vessel microwave digestion and inductively coupled plasma-mass spectrometry. These elements can adversely affect animal health when amounts become excessive or deficient in food. For potentially toxic elements, the target LOQ was determined to be 1/10 the lowest maximum tolerable level (MTL) for the most sensitive animal species. For nutritionally essential elements, the target LOQ was determined to be 1/10 the concentration that would be considered deficient in feed if that level is lower than 1/10 the lowest MTL. The targeted high end of the quantitation range was selected as twice the highest MTL. A single-laboratory validation (SLV) was performed to determine the accuracy and precision of the method, and the results were evaluated with respect to predetermined performance characteristics. The test materials used in the SLV included two National Institute of Standards and Technology certified reference materials, two Association of American Feed Control Officials (AAFCO) check samples, and one in-house previously analyzed feed sample. The concentrations of each element determined were the result of spiked analyte, incurred analyte, or a combination of spiked and incurred analyte. All samples were analyzed seven times on different days at 2 x LOQ and at the midrange concentration. For most data, the results of the SLV met or exceeded the criteria for accuracy and repeatability. For accuracy, K at the midrange level had a mean recovery of 95%, which is just below the low preferred accuracy threshold of 97%. For repeatability, all the 2 x LOQ CVr values were below the preferred values. Be, Cr, Ni, Na, Mn, and S all had midrange CVr values exceeding the preferred values. Be had the highest midrange CVr value of 9.93. Eight AAFCO check samples were also analyzed to determine the method's accuracy and repeatability for elements at the manufacturer's claimed levels. For accuracy, all results had z-scores <1.5. For repeatability, three CVr values from two AAFCO check samples were greater than the preferred limits.
引用
收藏
页码:434 / 444
页数:11
相关论文
共 50 条
  • [21] Determination of elements in carbon fiber using inductively coupled plasma mass spectrometry (ICP-MS)
    Zhao, Ting
    Zhou, Mingqiang
    Liu, Weili
    Huang, Wei
    He, Junzhi
    Chi, Haitao
    Gao, Xia
    APPLIED MATERIALS AND TECHNOLOGIES FOR MODERN MANUFACTURING, PTS 1-4, 2013, 423-426 : 767 - 770
  • [22] DETERMINATION OF LEAD BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY COMPARING SEVERAL CALIBRATION TECHNIQUES
    GOOSSENS, J
    MOENS, L
    DAMS, R
    ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) : 171 - 181
  • [23] Elemental bio-imaging of trace elements in teeth using laser ablation-inductively coupled plasma-mass spectrometry
    Hare, Dominic
    Austin, Christine
    Doble, Philip
    Arora, Manish
    JOURNAL OF DENTISTRY, 2011, 39 (05) : 397 - 403
  • [24] Determination of lead by hydride generation inductively coupled plasma mass spectrometry
    Li, JX
    Lu, F
    Umemura, T
    Tsunoda, K
    ANALYTICA CHIMICA ACTA, 2000, 419 (01) : 65 - 72
  • [25] Comparison of laser ablation-inductively coupled plasma-mass spectrometry and micro-X-ray fluorescence spectrometry for elemental imaging in Daphnia magna
    Gholap, Deepti S.
    Izmer, Andrei
    De Samber, Bjoern
    van Elteren, Johannes T.
    Selih, Vid S.
    Evens, Roel
    De Schamphelaere, Karel
    Janssen, Colin
    Balcaen, Lieve
    Lindemann, Inge
    Vincze, Laszlo
    Vanhaecke, Frank
    ANALYTICA CHIMICA ACTA, 2010, 664 (01) : 19 - 26
  • [26] Elucidation of tellurium biogenic nanoparticles in garlic, Allium sativum, by inductively coupled plasma-mass spectrometry
    Tanaka, Yu-ki
    Takada, Shohei
    Kumagai, Kazuhiro
    Kobayashi, Keita
    Hokura, Akiko
    Ogra, Yasumitsu
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2020, 62
  • [27] Characterization of Copper Bioavailability in Wheat Flour by Chemical Fractionation and Inductively Coupled Plasma-Mass Spectrometry
    Erdemir, Umran Seven
    Gucer, Seref
    ANALYTICAL LETTERS, 2016, 49 (07) : 1056 - 1065
  • [28] Detecting nanoparticulate silver using single-particle inductively coupled plasma-mass spectrometry
    Mitrano, Denise M.
    Lesher, Emily K.
    Bednar, Anthony
    Monserud, Jon
    Higgins, Christopher P.
    Ranville, James F.
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2012, 31 (01) : 115 - 121
  • [29] Determination of lead, cadmium and mercury in blood for assessment of environmental exposure: A comparison between inductively coupled plasma-mass spectrometry and atomic absorption spectrometry
    Palmer, Christopher D.
    Lewis, Miles E., Jr.
    Geraghty, Ciaran M.
    Barbosa, Fernando, Jr.
    Parsons, Patnck J.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (08) : 980 - 990
  • [30] DETERMINATION OF LEAD IN WHOLE-BLOOD USING INDUCTIVELY-COUPLED ARGON PLASMA-MASS SPECTROMETRY WITH ISOTOPE-DILUTION
    PASCHAL, DC
    CALDWELL, KL
    TING, BG
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (05) : 367 - 370