Determination of 27 Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry

被引:14
作者
King, Thomas [1 ]
Sheridan, Robert [1 ]
机构
[1] New York State Dept Agr & Markets Food Lab, 1220 Washington Ave, Albany, NY 12235 USA
关键词
RICE BRAN; CATTLE; COPPER; LEAD; INTOXICATION; TOXICITY; TISSUES;
D O I
10.5740/jaoacint.18-0198
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed to determine 27 elements (aluminum, arsenic, boron, cadmium, calcium, chromium, cobalt, copper, iron, lead, magnesium, manganese, mercury, molybdenum, nickel, phosphorus, potassium, selenium, sodium, sulfur, vanadium, zinc, antimony, uranium, beryllium, thallium, and thorium) in animal feeds and pet foods using closed vessel microwave digestion and inductively coupled plasma-mass spectrometry. These elements can adversely affect animal health when amounts become excessive or deficient in food. For potentially toxic elements, the target LOQ was determined to be 1/10 the lowest maximum tolerable level (MTL) for the most sensitive animal species. For nutritionally essential elements, the target LOQ was determined to be 1/10 the concentration that would be considered deficient in feed if that level is lower than 1/10 the lowest MTL. The targeted high end of the quantitation range was selected as twice the highest MTL. A single-laboratory validation (SLV) was performed to determine the accuracy and precision of the method, and the results were evaluated with respect to predetermined performance characteristics. The test materials used in the SLV included two National Institute of Standards and Technology certified reference materials, two Association of American Feed Control Officials (AAFCO) check samples, and one in-house previously analyzed feed sample. The concentrations of each element determined were the result of spiked analyte, incurred analyte, or a combination of spiked and incurred analyte. All samples were analyzed seven times on different days at 2 x LOQ and at the midrange concentration. For most data, the results of the SLV met or exceeded the criteria for accuracy and repeatability. For accuracy, K at the midrange level had a mean recovery of 95%, which is just below the low preferred accuracy threshold of 97%. For repeatability, all the 2 x LOQ CVr values were below the preferred values. Be, Cr, Ni, Na, Mn, and S all had midrange CVr values exceeding the preferred values. Be had the highest midrange CVr value of 9.93. Eight AAFCO check samples were also analyzed to determine the method's accuracy and repeatability for elements at the manufacturer's claimed levels. For accuracy, all results had z-scores <1.5. For repeatability, three CVr values from two AAFCO check samples were greater than the preferred limits.
引用
收藏
页码:434 / 444
页数:11
相关论文
共 50 条
  • [1] Determination of Tin in Canned Foods by Inductively Coupled Plasma-Mass Spectrometry
    Trandafir, Ion
    Nour, Violeta
    Ionica, Mira Elena
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2012, 21 (03): : 749 - 754
  • [2] Determination of Lead Species in Algae by Capillary Electrophoresis-Inductively Coupled Plasma-Mass Spectrometry
    Li Jing-Xi
    Sun Cheng-Jun
    Zheng Li
    Jiang Feng-Hua
    Yin Xiao-Fei
    Chen Jun-Hui
    Wang Xiao-Ru
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (11) : 1659 - 1664
  • [3] Study on the in vivo toxic mechanism of xixin based on trace elements determination by inductively coupled plasma-mass spectrometry
    Bao Yong-Rui
    Yang Xin-Xin
    Wang Shuai
    Meng Xian-Sheng
    Zhu Rui-Qing
    Xia Yue-Ming
    Cai Lin
    PHARMACOGNOSY MAGAZINE, 2014, 10 (38) : 141 - 146
  • [4] Determination of toxic and potentially toxic elements in rice and rice-based products by inductively coupled plasma-mass spectrometry
    Londonio, Agustin
    Morzan, Ezequiel
    Smichowski, Patricia
    FOOD CHEMISTRY, 2019, 284 : 149 - 154
  • [5] Lead Fractionation Analysis in Lipstick Samples by Inductively Coupled Plasma-Mass Spectrometry
    Yilmazcan, Ozlem
    Erdemir, Umran Seven
    Izgi, Belgin
    Ozer, Elif Tumay
    Gucer, Seref
    SPECTROSCOPY LETTERS, 2015, 48 (04) : 290 - 295
  • [6] SIMULTANEOUS DETERMINATION OF LEAD, BISMUTH AND THALLIUM IN PLASMA AND URINE BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    MAURAS, Y
    PREMELCABIC, A
    BERRE, S
    ALLAIN, P
    CLINICA CHIMICA ACTA, 1993, 218 (02) : 201 - 205
  • [7] TRACE DETERMINATION OF MANGANESE IN URINE BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    Golasik, Magdalena
    Herman, Malgorzata
    Piekoszewski, Wojciech
    Gomolka, Ewa
    Wodowski, Grzegorz
    Walas, Stanislaw
    ANALYTICAL LETTERS, 2014, 47 (11) : 1921 - 1930
  • [8] Accurate determination of silver nanoparticles in animal tissues by inductively coupled plasma mass spectrometry
    Veverkova, Lenka
    Hradilova, Sarka
    Milde, David
    Panacek, Ales
    Skopalova, Jana
    Kvitek, Libor
    Petrzlova, Kamila
    Zboril, Radek
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 102 : 7 - 11
  • [9] Determination of 18 Trace Elements in 10 Batches of the Tibetan Medicine Qishiwei Zhenzhu Pills by Direct Inductively Coupled Plasma-Mass Spectrometry
    Fu, Ke
    Song, Yinglian
    Zhang, Dewei
    Xu, Min
    Wu, Ruixia
    Xiong, Xueqing
    Liu, Xianwu
    Wu, Lei
    Guo, Ya
    Zhou, You
    Li, Xiaoli
    Wang, Zhang
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2022, 2022
  • [10] Determination of trace elements in high purity iron by solid phase extraction/inductively coupled plasma mass spectrometry
    Hasegawa, S
    Sato, K
    Ide, K
    Kobayashi, T
    Igarashi, S
    Naito, K
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2000, 64 (12) : 1212 - 1217