Liver motion during cone beam computed tomography guided stereotactic body radiation therapy

被引:93
|
作者
Park, Justin C. [1 ,3 ]
Park, Sung Ho [4 ]
Kim, Jong Hoon [4 ]
Yoon, Sang Min [4 ]
Song, Si Yeol [4 ]
Liu, Zhaowei [3 ]
Song, Bongyong [1 ]
Kauweloa, Kevin [1 ]
Webster, Matthew J. [1 ]
Sandhu, Ajay [1 ]
Mell, Loren K. [1 ]
Jiang, Steve B. [1 ]
Mundt, Arno J. [1 ]
Song, William Y. [1 ,2 ]
机构
[1] Univ Calif San Diego, Ctr Adv Radiotherapy Technol, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Radiat Med & Appl Sci, Rebecca & John Moores Comprehens Canc Ctr, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Elect & Comp Engn, La Jolla, CA 92093 USA
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiat Oncol, Seoul 138736, South Korea
基金
新加坡国家研究基金会;
关键词
liver motion; marker tracking; CBCT; IGRT; SBRT; REAL-TIME TUMOR; TRACKING RADIOTHERAPY; FIDUCIAL MARKERS; ABDOMINAL COMPRESSION; ORGAN MOTION; SET-UP; ACCURACY; FEASIBILITY; VARIABILITY; POSITION;
D O I
10.1118/1.4754658
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Understanding motion characteristics of liver such as, interfractional and intrafractional motion variability, difference in motion within different locations in the organ, and their complex relationship with the breathing cycles are particularly important for image-guided liver SBRT. The purpose of this study was to investigate such motion characteristics based on fiducial markers tracked with the x-ray projections of the CBCT scans, taken immediately prior to the treatments. Methods: Twenty liver SBRT patients were analyzed. Each patient had three fiducial markers (2 x 5-mm gold) percutaneously implanted around the gross tumor. The prescription ranged from 2 to 8 fractions per patient. The CBCT projections data for each fraction (similar to 650 projections/scan), for each patient, were analyzed and the 2D positions of the markers were extracted using an in-house algorithm. In total, >55 000 x-ray projections were analyzed from 85 CBCT scans. From the 2D extracted positions, a 3D motion trajectory of the markers was constructed, from each CBCT scans, resulting in left-right (LR), anterior-posterior (AP), and cranio-caudal (CC) location information of the markers with >55 000 data points. The authors then analyzed the interfraction and intrafraction liver motion variability, within different locations in the organ, and as a function of the breathing cycle. The authors also compared the motion characteristics against the planning 4DCT and the RPM (TM) (Varian Medical Systems, Palo Alto, CA) breathing traces. Variations in the appropriate gating window (defined as the percent of the maximum range at which 50% of the marker positions are contained), between fractions were calculated as well. Results: The range of motion for the 20 patients were 3.0 +/- 2.0 mm, 5.1 +/- 3.1 mm, and 17.9 +/- 5.1 mm in the planning 4DCT, and 2.8 +/- 1.6 mm, 5.3 +/- 3.1 mm, and 16.5 +/- 5.7 mm in the treatment CBCT, for LR, AP, and CC directions, respectively. The range of respiratory period was 3.9 +/- 0.7 and 4.2 +/- 0.8 s during the 4DCT simulation and the CBCT scans, respectively. The authors found that breathing-induced AP and CC motions are highly correlated. That is, all markers moved cranially also moved posteriorly and vice versa, irrespective of the location. The LR motion had a more variable relationship with the AP/CC motions, and appeared random with respect to the location. That is, when the markers moved toward cranial-posterior direction, 58% of the markers moved to the patient-right, 22% of the markers moved to the patient-left, and 20% of the markers had minimal/none motion. The absolute difference in the motion magnitude between the markers, in different locations within the liver, had a positive correlation with the absolute distance between the markers (R-2 = 0.69, linear-fit). The interfractional gating window varied significantly for some patients, with the largest having 29.4%-56.4% range between fractions. Conclusions: This study analyzed the liver motion characteristics of 20 patients undergoing SBRT. A large variation in motion was observed, interfractionally and intrafractionally, and that as the distance between the markers increased, the difference in the absolute range of motion also increased. This suggests that marker(s) in closest proximity to the target be used. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4754658]
引用
收藏
页码:6431 / 6442
页数:12
相关论文
共 50 条
  • [41] Stereotactic body radiation therapy for liver metastases
    Dawood, Omar
    Mahadevan, Anand
    Goodman, Karyn A.
    EUROPEAN JOURNAL OF CANCER, 2009, 45 (17) : 2947 - 2959
  • [42] Cone-beam computed tomography in hypofractionated stereotactic radiotherapy for brain metastases
    Ingrosso, Gianluca
    Miceli, Roberto
    Fedele, Dahlia
    Ponti, Elisabetta
    Benassi, Michaela
    Barbarino, Rosaria
    Di Murro, Luana
    Giudice, Emilia
    Santarelli, Federico
    Santoni, Riccardo
    RADIATION ONCOLOGY, 2012, 7
  • [43] Surface guided frameless positioning for lung stereotactic body radiation therapy
    Sarudis, Sebastian
    Karlsson, Anna
    Back, Anna
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 215 - 226
  • [44] Stereotactic Body Radiation Therapy for Liver Metastases
    Krug, David
    Blanck, Oliver
    Boda-Heggemann, Judit
    Dunst, Juergen
    ZENTRALBLATT FUR CHIRURGIE, 2019, 144 (03): : 242 - 251
  • [45] Stereotactic body radiation therapy planning for liver tumors using functional images from dual-energy computed tomography
    Ohira, Shingo
    Kanayama, Naoyuki
    Toratani, Masayasu
    Ueda, Yoshihiro
    Koike, Yuhei
    Karino, Tsukasa
    Shunsuke, Ono
    Miyazaki, Masayoshi
    Koizumi, Masahiko
    Teshima, Teruki
    RADIOTHERAPY AND ONCOLOGY, 2020, 145 : 56 - 62
  • [46] Investigating the Possibility of Using Cone Beam Computed Tomography (CBCT) for Radiation Therapy Treatment Planning
    E. N. Lykova
    E. P. Morozova
    S. S. Khromov
    A. P. Chernyaev
    Moscow University Physics Bulletin, 2021, 76 : 233 - 239
  • [47] Dose estimation for cone-beam computed tomography in image-guided radiation therapy using mesh-type reference computational phantoms and assuming head and neck cancer
    Cumur, Ceyda
    Fujibuchi, Toshioh
    Hamada, Keisuke
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [48] Cone Beam Computed Tomography for Adaptive Radiotherapy Treatment Planning
    Srinivasan, Kavitha
    Mohammadi, Mohammad
    Shepherd, Justin
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2014, 34 (04) : 377 - 385
  • [49] Effects of respiratory motion on accurate four-dimensional computed tomography acquisition and plan delivery for lung stereotactic body radiation therapy
    Bae, Bong Kyung
    Kim, Sung Joon
    Kim, Jae-Chul
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 84 (04) : 323 - 334
  • [50] Investigating the Possibility of Using Cone Beam Computed Tomography (CBCT) for Radiation Therapy Treatment Planning
    Lykova, E. N.
    Morozova, E. P.
    Khromov, S. S.
    Chernyaev, A. P.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (04) : 233 - 239