Liver motion during cone beam computed tomography guided stereotactic body radiation therapy

被引:93
|
作者
Park, Justin C. [1 ,3 ]
Park, Sung Ho [4 ]
Kim, Jong Hoon [4 ]
Yoon, Sang Min [4 ]
Song, Si Yeol [4 ]
Liu, Zhaowei [3 ]
Song, Bongyong [1 ]
Kauweloa, Kevin [1 ]
Webster, Matthew J. [1 ]
Sandhu, Ajay [1 ]
Mell, Loren K. [1 ]
Jiang, Steve B. [1 ]
Mundt, Arno J. [1 ]
Song, William Y. [1 ,2 ]
机构
[1] Univ Calif San Diego, Ctr Adv Radiotherapy Technol, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Radiat Med & Appl Sci, Rebecca & John Moores Comprehens Canc Ctr, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Elect & Comp Engn, La Jolla, CA 92093 USA
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiat Oncol, Seoul 138736, South Korea
基金
新加坡国家研究基金会;
关键词
liver motion; marker tracking; CBCT; IGRT; SBRT; REAL-TIME TUMOR; TRACKING RADIOTHERAPY; FIDUCIAL MARKERS; ABDOMINAL COMPRESSION; ORGAN MOTION; SET-UP; ACCURACY; FEASIBILITY; VARIABILITY; POSITION;
D O I
10.1118/1.4754658
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Understanding motion characteristics of liver such as, interfractional and intrafractional motion variability, difference in motion within different locations in the organ, and their complex relationship with the breathing cycles are particularly important for image-guided liver SBRT. The purpose of this study was to investigate such motion characteristics based on fiducial markers tracked with the x-ray projections of the CBCT scans, taken immediately prior to the treatments. Methods: Twenty liver SBRT patients were analyzed. Each patient had three fiducial markers (2 x 5-mm gold) percutaneously implanted around the gross tumor. The prescription ranged from 2 to 8 fractions per patient. The CBCT projections data for each fraction (similar to 650 projections/scan), for each patient, were analyzed and the 2D positions of the markers were extracted using an in-house algorithm. In total, >55 000 x-ray projections were analyzed from 85 CBCT scans. From the 2D extracted positions, a 3D motion trajectory of the markers was constructed, from each CBCT scans, resulting in left-right (LR), anterior-posterior (AP), and cranio-caudal (CC) location information of the markers with >55 000 data points. The authors then analyzed the interfraction and intrafraction liver motion variability, within different locations in the organ, and as a function of the breathing cycle. The authors also compared the motion characteristics against the planning 4DCT and the RPM (TM) (Varian Medical Systems, Palo Alto, CA) breathing traces. Variations in the appropriate gating window (defined as the percent of the maximum range at which 50% of the marker positions are contained), between fractions were calculated as well. Results: The range of motion for the 20 patients were 3.0 +/- 2.0 mm, 5.1 +/- 3.1 mm, and 17.9 +/- 5.1 mm in the planning 4DCT, and 2.8 +/- 1.6 mm, 5.3 +/- 3.1 mm, and 16.5 +/- 5.7 mm in the treatment CBCT, for LR, AP, and CC directions, respectively. The range of respiratory period was 3.9 +/- 0.7 and 4.2 +/- 0.8 s during the 4DCT simulation and the CBCT scans, respectively. The authors found that breathing-induced AP and CC motions are highly correlated. That is, all markers moved cranially also moved posteriorly and vice versa, irrespective of the location. The LR motion had a more variable relationship with the AP/CC motions, and appeared random with respect to the location. That is, when the markers moved toward cranial-posterior direction, 58% of the markers moved to the patient-right, 22% of the markers moved to the patient-left, and 20% of the markers had minimal/none motion. The absolute difference in the motion magnitude between the markers, in different locations within the liver, had a positive correlation with the absolute distance between the markers (R-2 = 0.69, linear-fit). The interfractional gating window varied significantly for some patients, with the largest having 29.4%-56.4% range between fractions. Conclusions: This study analyzed the liver motion characteristics of 20 patients undergoing SBRT. A large variation in motion was observed, interfractionally and intrafractionally, and that as the distance between the markers increased, the difference in the absolute range of motion also increased. This suggests that marker(s) in closest proximity to the target be used. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4754658]
引用
收藏
页码:6431 / 6442
页数:12
相关论文
共 50 条
  • [31] Clinical Implementation of Cone Beam Computed Tomography-Guided Online Adaptive Radiation Therapy in Whole Breast Irradiation
    Nelissen, Koen J.
    Verbakel, Wilko F. A. R.
    Middelburg Van-Rijn, Judith G.
    Rijksen, Barbara L. T.
    Admiraal, Marjan A.
    Visser, Jorrit
    van der Himst, Jessica
    Goudschaal, Karin N.
    Bucko, Ewa
    Slotman, Ben J.
    van Vlaenderen, Angelique R. W.
    van den Bongard, Desiree H. J. G.
    BREAST ART Study Grp
    ADVANCES IN RADIATION ONCOLOGY, 2025, 10 (01)
  • [32] Clinical impact of cone beam computed tomography on iterative treatment planning during ultrasound-guided percutaneous ablation of liver malignancies
    Floridi, Chiara
    Radaelli, Alessandro
    Pesapane, Filippo
    Fumarola, Enrico Maria
    Lecchi, Michela
    Agostini, Andrea
    Giovagnoni, Andrea
    Carrafiello, Gianpaolo
    Wood, Bradford
    MEDICAL ONCOLOGY, 2017, 34 (06)
  • [33] Surgeon radiation exposure in cone beam computed tomography-based, image-guided spinal surgery
    Nottmeier, Eric W.
    Bowman, Cammi
    Nelson, Kevin L.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2012, 8 (02) : 196 - 200
  • [34] Characteristics and dosimetric impact of intrafraction motion during peripheral lung cancer stereotactic radiotherapy: is a second midpoint cone beam computed tomography of added value?
    Benkhaled, Sofian
    Koshariuk, Olga
    Van Esch, Ann
    Remouchamps, Vincent
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (03) : 490 - 499
  • [35] Comparison of different registration methods in cone-beam computed tomography for breast boost radiation therapy
    Lastrucci, A.
    Fedeli, L.
    Marciello, L.
    Serventi, E.
    Segnini, S.
    Meucci, F.
    Bernardi, L.
    Ricci, R.
    Marzano, S.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [36] The importance of cone-beam computed tomography in endodontic therapy: A review
    Kolarkodi, Shaul Hameed
    SAUDI DENTAL JOURNAL, 2023, 35 (07) : 780 - 784
  • [37] Radiation safety issues with positron-emission/computed tomography simulation for stereotactic body radiation therapy
    Kearns, William T.
    Urbanic, James J.
    Hampton, Carnell J.
    McMullen, Kevin P.
    Blackstock, A. William
    Stieber, Volker W.
    Hinson, William H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (03): : 141 - 146
  • [38] Observational study of cone beam computed tomography based interfractional urinary bladder filling variation during image guided radiation therapy in pelvic malignancies
    Shah, Manjari
    Agarwal, Sandeep
    Agarwal, Rashi
    Subramanian, Bala
    Gupta, Sweety
    De, Sudarsan
    Mishra, Shiv
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (01) : 152 - 156
  • [39] Stereotactic body radiation therapy for liver tumours
    Maingon, P.
    Nouhaud, E.
    Mornex, F.
    Crehange, G.
    CANCER RADIOTHERAPIE, 2014, 18 (04): : 313 - 319
  • [40] Cone-beam CT radiomics for early response assessment in liver stereotactic body radiation therapy: Results of a pilot study
    Shan, Jingjing
    Yang, Pengfei
    Yen, Eric
    Zhou, Qinxuan
    Gu, Benxing
    Xie, Xuyun
    Wang, Jing
    Niu, Tianye
    Sun, Xiaonan
    CANCER RADIOTHERAPIE, 2025, 29 (01):