Possible utility of MRI using Gd-EOB-DTPA for estimating liver functional reserve

被引:85
作者
Utsunomiya, Tohru [1 ]
Shimada, Mitsuo [1 ]
Hanaoka, Jun [1 ]
Kanamoto, Mami [1 ]
Ikemoto, Tetsuya [1 ]
Morine, Yuji [1 ]
Imura, Satoru [1 ]
Harada, Masafui [2 ]
机构
[1] Univ Tokushima, Dept Surg, Tokushima 7708503, Japan
[2] Univ Tokushima, Dept Radiol, Tokushima 7708503, Japan
基金
日本学术振兴会;
关键词
Fusion imaging; MR imaging; Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA); Scintigraphy with [Tc-99m] galactosyl human serum albumin (GSA); HEPATOBILIARY SCINTIGRAPHY; HEPATOCELLULAR FUNCTION; HEPATIC RESECTION; CONTRAST AGENT; PHASE; FAILURE; IMAGES;
D O I
10.1007/s00535-011-0513-8
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Preoperative estimation of the liver functional reserve is important in liver surgery. We evaluated the role of dynamic magnetic resonance (MR) imaging with gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA), i.e., EOB-MRI, for determining liver functional reserve. Fifty patients who underwent EOB-MRI to examine their liver tumors were included in this study. We first performed a pixel-by-pixel comparison of registered MR images and activity images with Tc-99m galactosyl human serum albumin (GSA) on each slice, and the correlation coefficient was calculated for 8 patients. We also determined the correlation coefficient between the relative signal intensity (SI) values of EOB-MRI and preoperative liver function, such as the GSA, indocyanine green dye retention at 15 min (ICGR15), and prothrombin time. The mean of the correlation coefficients for 512 x 512 matrices between the EOB-MRI and the GSA was 0.83 +/- A 0.05 (ranging from 0.73 to 0.87). The correlation coefficient between the relative SI of the EOB-MRI and the receptor index (LHL15) of GSA was 0.56 (P < 0.01). Better correlation coefficients were observed between the relative SI and the liver function test, including ICGR15 (r = -0.67, P < 0.01) and prothrombin time (r = 0.59, P < 0.01). In a patient with hilar cholangiocarcinoma whose right hepatic duct was obstructed, the relative SI in the right lobe (2.4 +/- A 0.3) was significantly lower than that in the left lobe (3.1 +/- A 0.1). EOB-MRI represents a practical and reliable imaging technique that may be used to estimate regional liver functional reserve in the clinical setting.
引用
收藏
页码:470 / 476
页数:7
相关论文
共 29 条
  • [1] Akaki S, 1999, J NUCL MED, V40, P394
  • [2] Results of surgical and nonsurgical treatment for small-sized hepatocellular carcinomas: A retrospective and nationwide survey in Japan
    Arii, S
    Yamaoka, Y
    Futagawa, S
    Inoue, K
    Kobayashi, K
    Kojiro, M
    Makuuchi, M
    Nakamura, Y
    Okita, K
    Yamada, R
    [J]. HEPATOLOGY, 2000, 32 (06) : 1224 - 1229
  • [3] General multilevel linear modeling for group analysis in FMRI
    Beckmann, CF
    Jenkinson, M
    Smith, SM
    [J]. NEUROIMAGE, 2003, 20 (02) : 1052 - 1063
  • [4] Efficacy and safety of MR imaging with liver-specific contrast agent: US Multicenter Phase III study
    Bluemke, DA
    Sahani, D
    Amendola, M
    Balzer, T
    Breuer, J
    Brown, JJ
    Casalino, DD
    Davis, PL
    Francis, IR
    Krinsky, G
    Lee, FT
    Lu, D
    Paulson, EK
    Schwartz, LH
    Siegelman, ES
    [J]. RADIOLOGY, 2005, 237 (01) : 89 - 98
  • [5] 99mTc-Mebrofenin Hepatobiliary Scintigraphy with SPECT for the Assessment of Hepatic Function and Liver Functional Volume Before Partial Hepatectomy
    de Graaf, Wilmar
    van Lienden, Krijn P.
    van Gulik, Thomas M.
    Bennink, Roelof J.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) : 229 - 236
  • [6] Risk assessment of posthepatectomy liver failure using hepatobiliary scintigraphy and CT volumetry
    Dinant, Sander
    de Graaf, Wilmar
    Verwer, Bart J.
    Bennink, Roelof J.
    van Lienden, Krijn P.
    Gouma, Dirk J.
    van Vliet, Arlne K.
    van Gulik, Thomas M.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) : 685 - 692
  • [7] FMRIB, 2011, FMRIBS LIN IM REG TO
  • [8] Improved detection of focal liver lesions at MR imaging: Multicenter comparison of gadoxetic acid-enhanced MR images with intraoperative findings
    Huppertz, A
    Balzer, T
    Blakeborough, A
    Breuer, L
    Giovagnoni, A
    Heinz-Peer, G
    Laniado, M
    Manfredi, RM
    Mathieu, DG
    Mueller, D
    Reimer, P
    Robinson, PJ
    Strotzer, M
    Taupitz, M
    Vogl, TJ
    [J]. RADIOLOGY, 2004, 230 (01) : 266 - 275
  • [9] Improved optimization for the robust and accurate linear registration and motion correction of brain images
    Jenkinson, M
    Bannister, P
    Brady, M
    Smith, S
    [J]. NEUROIMAGE, 2002, 17 (02) : 825 - 841
  • [10] MEASUREMENT OF HEPATOCELLULAR FUNCTION WITH DECONVOLUTIONAL ANALYSIS - APPLICATION IN THE DIFFERENTIAL-DIAGNOSIS OF ACUTE JAUNDICE
    JUNI, JE
    REICHLE, R
    [J]. RADIOLOGY, 1990, 177 (01) : 171 - 175