Possible utility of MRI using Gd-EOB-DTPA for estimating liver functional reserve

被引:87
作者
Utsunomiya, Tohru [1 ]
Shimada, Mitsuo [1 ]
Hanaoka, Jun [1 ]
Kanamoto, Mami [1 ]
Ikemoto, Tetsuya [1 ]
Morine, Yuji [1 ]
Imura, Satoru [1 ]
Harada, Masafui [2 ]
机构
[1] Univ Tokushima, Dept Surg, Tokushima 7708503, Japan
[2] Univ Tokushima, Dept Radiol, Tokushima 7708503, Japan
基金
日本学术振兴会;
关键词
Fusion imaging; MR imaging; Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA); Scintigraphy with [Tc-99m] galactosyl human serum albumin (GSA); HEPATOBILIARY SCINTIGRAPHY; HEPATOCELLULAR FUNCTION; HEPATIC RESECTION; CONTRAST AGENT; PHASE; FAILURE; IMAGES;
D O I
10.1007/s00535-011-0513-8
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Preoperative estimation of the liver functional reserve is important in liver surgery. We evaluated the role of dynamic magnetic resonance (MR) imaging with gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA), i.e., EOB-MRI, for determining liver functional reserve. Fifty patients who underwent EOB-MRI to examine their liver tumors were included in this study. We first performed a pixel-by-pixel comparison of registered MR images and activity images with Tc-99m galactosyl human serum albumin (GSA) on each slice, and the correlation coefficient was calculated for 8 patients. We also determined the correlation coefficient between the relative signal intensity (SI) values of EOB-MRI and preoperative liver function, such as the GSA, indocyanine green dye retention at 15 min (ICGR15), and prothrombin time. The mean of the correlation coefficients for 512 x 512 matrices between the EOB-MRI and the GSA was 0.83 +/- A 0.05 (ranging from 0.73 to 0.87). The correlation coefficient between the relative SI of the EOB-MRI and the receptor index (LHL15) of GSA was 0.56 (P < 0.01). Better correlation coefficients were observed between the relative SI and the liver function test, including ICGR15 (r = -0.67, P < 0.01) and prothrombin time (r = 0.59, P < 0.01). In a patient with hilar cholangiocarcinoma whose right hepatic duct was obstructed, the relative SI in the right lobe (2.4 +/- A 0.3) was significantly lower than that in the left lobe (3.1 +/- A 0.1). EOB-MRI represents a practical and reliable imaging technique that may be used to estimate regional liver functional reserve in the clinical setting.
引用
收藏
页码:470 / 476
页数:7
相关论文
共 29 条
[1]  
Akaki S, 1999, J NUCL MED, V40, P394
[2]   Results of surgical and nonsurgical treatment for small-sized hepatocellular carcinomas: A retrospective and nationwide survey in Japan [J].
Arii, S ;
Yamaoka, Y ;
Futagawa, S ;
Inoue, K ;
Kobayashi, K ;
Kojiro, M ;
Makuuchi, M ;
Nakamura, Y ;
Okita, K ;
Yamada, R .
HEPATOLOGY, 2000, 32 (06) :1224-1229
[3]   General multilevel linear modeling for group analysis in FMRI [J].
Beckmann, CF ;
Jenkinson, M ;
Smith, SM .
NEUROIMAGE, 2003, 20 (02) :1052-1063
[4]   Efficacy and safety of MR imaging with liver-specific contrast agent: US Multicenter Phase III study [J].
Bluemke, DA ;
Sahani, D ;
Amendola, M ;
Balzer, T ;
Breuer, J ;
Brown, JJ ;
Casalino, DD ;
Davis, PL ;
Francis, IR ;
Krinsky, G ;
Lee, FT ;
Lu, D ;
Paulson, EK ;
Schwartz, LH ;
Siegelman, ES .
RADIOLOGY, 2005, 237 (01) :89-98
[5]   99mTc-Mebrofenin Hepatobiliary Scintigraphy with SPECT for the Assessment of Hepatic Function and Liver Functional Volume Before Partial Hepatectomy [J].
de Graaf, Wilmar ;
van Lienden, Krijn P. ;
van Gulik, Thomas M. ;
Bennink, Roelof J. .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) :229-236
[6]   Risk assessment of posthepatectomy liver failure using hepatobiliary scintigraphy and CT volumetry [J].
Dinant, Sander ;
de Graaf, Wilmar ;
Verwer, Bart J. ;
Bennink, Roelof J. ;
van Lienden, Krijn P. ;
Gouma, Dirk J. ;
van Vliet, Arlne K. ;
van Gulik, Thomas M. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) :685-692
[7]  
FMRIB, 2011, FMRIBS LIN IM REG TO
[8]   Improved detection of focal liver lesions at MR imaging: Multicenter comparison of gadoxetic acid-enhanced MR images with intraoperative findings [J].
Huppertz, A ;
Balzer, T ;
Blakeborough, A ;
Breuer, L ;
Giovagnoni, A ;
Heinz-Peer, G ;
Laniado, M ;
Manfredi, RM ;
Mathieu, DG ;
Mueller, D ;
Reimer, P ;
Robinson, PJ ;
Strotzer, M ;
Taupitz, M ;
Vogl, TJ .
RADIOLOGY, 2004, 230 (01) :266-275
[9]   Improved optimization for the robust and accurate linear registration and motion correction of brain images [J].
Jenkinson, M ;
Bannister, P ;
Brady, M ;
Smith, S .
NEUROIMAGE, 2002, 17 (02) :825-841
[10]   MEASUREMENT OF HEPATOCELLULAR FUNCTION WITH DECONVOLUTIONAL ANALYSIS - APPLICATION IN THE DIFFERENTIAL-DIAGNOSIS OF ACUTE JAUNDICE [J].
JUNI, JE ;
REICHLE, R .
RADIOLOGY, 1990, 177 (01) :171-175