Brain Imaging with Slotted Hybridized Magnetic Metamaterial Hat at 7-T MRI

被引:5
|
作者
Ali, Hassan [1 ]
Forsberg, Erik [1 ]
Jun, Hu [1 ]
机构
[1] Zhejiang Univ, Dept Opt Engn, Ctr Opt & Electromagnet Res, State Key Lab Modern Opt Instrumentat, Hangzhou 310058, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
TO-NOISE RATIO; RADIOFREQUENCY COIL; EFFICIENT;
D O I
10.1007/s00723-016-0848-7
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Study of human pathologies and acquisition of anatomical images without any surgical intervention inside human body is possible because of magnetic resonance imaging (MRI), which is the keystone technique to characterize the psychology and neurochemistry of human body. However, for clinical trials, the study and cure of human diseases are followed by medical investigations of different animal anatomies. By employing different imaging techniques to animal anatomical models during their clinical trials yielded in exceptional image acquisition without any surgical invasion in the model, which resulted in noninvasive technique as compared to surgical invasion and opened the possibility to study human pathologies more precisely. This work exploits the notable properties of unique combination of multi-circular hybridized surface coils which can be used as hybridized magnetic metamaterial hat (HMMH). HMMH not only strengthens the uniformity of radio frequency (RF) rotational symmetry around its axis but also improves the signal-to-noise ratio (SNR) for rat's brain imaging at 7-T MRI. We analyzed a periodic array of strongly coupled circular copper coils attached on circular coil shaped printed circuit board (PCB) substrate. In the design, some copper coils were inspired by the slot cavity loaded with parametric elements (capacitor and inductor). In addition, coils in the form of HMMH exploited the advantages of the hybrid modes which exhibited better and deeper RF sensitivity into the region of interest (ROI) as compared to single loop RF coil by exciting two Eigen modes simultaneously which resulted in homogenized magnetic field ( B-field) and enhanced SNR at ROI. At resonance, the value of relative negative permeability, mu(r) = -7 + j11 was achieved at 300 MHz for 7-T MRI. Furthermore, image quality at ROI was optimized by varying rat's head position under magnetic resonance (MR) coil of MRI apparatus and in the presence or absence of HMMH. Design configuration and circuit model analysis were also done.
引用
收藏
页码:67 / 83
页数:17
相关论文
共 50 条
  • [21] 7-T Diffusion Tensor Imaging and Fiber Tracking
    Sammet, S.
    Irfanoglu, O.
    Sammet, C.
    Yuh, W.
    Knopp, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [22] A 7-T Actively Shielded Superconducting Magnet for Animal MRI
    Jiang, Xiaohua
    Guo, Yan
    Chen, Jiangbo
    Chai, Guolin
    Liu, Siyuan
    Zhang, Tieshan
    Wang, Lixiang
    Yang, Taofeng
    Cheng, Hongxiang
    Deng, Huijuan
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [23] Osteochondritis Dissecans of the Knee at 7-T Trabecular Bone MRI
    Zhen, Zhiming
    Chen, Wei
    RADIOLOGY, 2024, 311 (03)
  • [24] Retrobulbar vasculature using 7-T magnetic resonance imaging with dedicated eye surface coil
    John B. Christoforidis
    Peter A. Wassenaar
    Greg A. Christoforidis
    Vincent Y. Ho
    Michael V. Knopp
    Petra M. Schmalbrock
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 271 - 277
  • [25] Precentral and cerebellar atrophic changes in moyamoya disease using 7-T magnetic resonance imaging
    Moon, Hyeong Cheol
    Oh, Byeong Ho
    Cheong, Chaejoon
    Kim, Won Seop
    Min, Kyung Soo
    Kim, Young Gyu
    Park, Young Seok
    ACTA RADIOLOGICA, 2020, 61 (04) : 487 - 495
  • [26] Retrobulbar vasculature using 7-T magnetic resonance imaging with dedicated eye surface coil
    Christoforidis, John B.
    Wassenaar, Peter A.
    Christoforidis, Greg A.
    Ho, Vincent Y.
    Knopp, Michael V.
    Schmalbrock, Petra M.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (01) : 271 - 277
  • [27] Subchondral bone microarchitecture analysis in the proximal tibia at 7-T MRI
    Agten, Christoph A.
    Honig, Stephen
    Saha, Punam K.
    Regatte, Ravinder
    Chang, Gregory
    ACTA RADIOLOGICA, 2018, 59 (06) : 716 - 722
  • [28] Use of a Commercial 7-T MRI Scanner for Clinical Brain Imaging: Indications, Protocols, Challenges, and Solutions-A Single-Center Experience
    Ozutemiz, Can
    White, Matthew
    Elvendahl, Wendy
    Eryaman, Yigitcan
    Marjanska, Malgorzata
    Metzger, Gregory J.
    Patriat, Remi
    Kulesa, Jeramy
    Harel, Noam
    Watanabe, Yoichi
    Grant, Andrea
    Genovese, Guglielmo
    Cayci, Zuzan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 221 (06) : 788 - 805
  • [29] MAGNETIC RESONANCE IMAGING OF THE CANINE BRAIN AT 7 T
    Kang, Byeong-Teck
    Ko, Ki-Jin
    Jang, Dong-Pyo
    Han, Jae-Yong
    Lim, Chae-Young
    Park, Chul
    Yoo, Jong-Hyun
    Kim, Ju-Won
    Jung, Dong-In
    Kim, Young-Bo
    Woo, Eung-Je
    Cho, Zang-Hee
    Park, Hee-Myung
    VETERINARY RADIOLOGY & ULTRASOUND, 2009, 50 (06) : 615 - 621
  • [30] 7-T Neuromelanin and R2*MRI in Parkinson Disease
    Lakhani, Dhairya A.
    Middlebrooks, Erik H.
    RADIOLOGY, 2022, 305 (02) : 296 - 296