Feasibility of drying system using waste heat as the heating source

被引:0
|
作者
Xie, M. N. [1 ]
Shi, Y. L. [1 ]
Chen, L. X. [1 ]
机构
[1] Chinese Acad Sci, Fujian Inst Res Struct Matter, Quanzhou Inst Equipment Mfg, Beijing 100864, Peoples R China
关键词
D O I
10.1088/1755-1315/40/1/012031
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, a wastewater heat pump system was proposed and its thermal performance was analyzed. The proposed system includes two evaporators: an air-source evaporator and a water-source evaporator. The air-source evaporator absorbs heat from the moist hot air which exhaust from the drying oven. The water-source evaporator absorbs heat from the waste water, while the waste water recovers heat from the mechanical energy, which was produced by cutting and polishing in stone production. The thermodynamic model was developed to evaluate the performance of the proposed system. The energetic analysis was carried out to investigate the influences of the temperature of fresh air. The results show significantly higher energy efficiency, compact-sized and energy-saving compared with the system which uses air as the heat source. Among the seven of alternative refrigerants (R152a, R123, R1234yf, R1234ze, R600a, R22 and R600) investigated, R123 was suggested to be used in this heat pump for its high heating efficiency, inflammable, very low ODP(Ozone Depletion Potential) and GWP(Global warming potential).
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Feasibility limits of using low-grade industrial waste heat in symbiotic district heating and cooling networks
    Santin, Maurizio
    Chinese, Damiana
    De Angelis, Alessandra
    Biberacher, Markus
    CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2020, 22 (06) : 1339 - 1357
  • [32] Utilization of waste heat from commercial kitchen exhaust for water heating and dish drying
    Wang, Yuan
    Shen, Chao
    Sun, Pengyi
    Li, Chengyao
    Zhang, Chunxiao
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [33] DRYING COTTON WITH WASTE HEAT
    CARRIERE, B
    AGRICULTURAL RESEARCH, 1986, 34 (05) : 14 - 14
  • [34] Heating and cooling experiments and feasibility study using heating and cooling load model for ground water heat pump system
    Nam, Yujin
    Ooka, Ryozo
    Journal of Environmental Engineering, 2009, 74 (638) : 473 - 479
  • [35] CYCLIC TUNNEL DRYING OF SEWER PIPE USING WASTE HEAT
    REED, ND
    AMERICAN CERAMIC SOCIETY BULLETIN, 1977, 56 (03): : 354 - 354
  • [36] FEASIBILITY STUDY OF HEAT PUMP IN MAINE USING ATTIC HEAT SOURCE
    Lin, Lin
    Knittweis, Stephen
    Doxsey, Julie
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 6A, 2014,
  • [37] The feasibility of using a septic tank as a heat source for geothermal heat pumps
    Hanegan, T
    DenBraven, K
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (04): : 207 - 209
  • [38] FEASIBILITY STUDY OF A SUPERCRITICAL CYCLE AS A WASTE HEAT RECOVERY SYSTEM
    Agresta, Antonio
    Ingenito, Antonella
    Andriani, Roberto
    Gamma, Faust
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 6A, 2014,
  • [39] Experimental study on drying characteristics of compressed air drying system using liquid desiccant driven by air compressor waste heat
    Wang Z.
    Yin Y.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2019, 49 (05): : 851 - 857
  • [40] Waste steam over heating for drying purposes
    不详
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1922, 66 : 996 - 996