Cyclic strain amplitude dictates the growth response of vascular smooth muscle cells in vitro: role in in-stent restenosis and inhibition with a sirolimus drug-eluting stent

被引:16
作者
Colombo, Alberto [1 ,2 ]
Guha, Shaunta [2 ]
Mackle, Joseph N. [2 ]
Cahill, Paul A. [2 ,3 ]
Lally, Caitriona [1 ,3 ]
机构
[1] Dublin City Univ, Sch Mech & Mfg Engn, Dublin 9, Ireland
[2] Dublin City Univ, Sch Biotechnol, Fac Sci & Hlth, Dublin 9, Ireland
[3] Dublin City Univ, Ctr Med Engn Res, Dublin 9, Ireland
基金
爱尔兰科学基金会;
关键词
Vascular smooth muscle cells; Cyclic strain; Restenosis; Stents; Apoptosis; Proliferation; COMPLIANCE MATCHING STENT; CORONARY-ARTERY-DISEASE; FINITE-ELEMENT-ANALYSIS; FLUID SHEAR-STRESS; WALL MECHANICS; MYOCARDIAL-INFARCTION; BALLOON ANGIOPLASTY; RABBIT AORTA; LONG-TERM; IMPLANTATION;
D O I
10.1007/s10237-012-0433-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The putative effects of changes in mean strain and cyclic strain amplitude on vascular smooth muscle cell (vSMC) growth (proliferation and apoptosis) were examined. Subsequently, a quantitative measure of vSMC growth was obtained to determine the prolonged effect of changes in mechanical burden following bare-metal stent (BMS) and sirolimus drug-eluting stent (DES) deployment in vitro. Bovine aortic vSMCs were exposed to prolonged cyclic strain using a Flexercell(TM) Tension system and a novel Sylgard(TM) phantom vessel following stent implantation before the level of vSMC proliferation and apoptosis was assessed by FACS analysis, cell counting, and immunocytochemistry. Physiological cyclic strain (5%) decreased vSMC proliferation and increased apoptosis in a temporal manner. There was no significant difference in cell growth following exposure to varying mean strains with similar amplitude. In contrast, exposure to varying strain amplitudes with similar mean strains resulted in significant differences in cell proliferation and apoptosis. In parallel studies, the level of vSMC proliferation and cell survival was significantly increased within low amplitude, high mean strain regions of a phantom vessel following BMS implantation when compared to regions of higher strain amplitude upstream and downstream of the stent, respectively. Moreover, the level of vSMC growth within the stented region was significantly attenuated following implantation of a sirolimus-coated DES independent of significant changes in cell survival. Cyclic strain amplitude is an important regulator of vSMC growth capacity within a stent and is a target for inhibition using a sirolimus-coated DES.
引用
收藏
页码:671 / 683
页数:13
相关论文
共 44 条
  • [1] Increased Synthetic Phenotype Behavior of Smooth Muscle Cells in Response to In Vitro Balloon Angioplasty Injury Model
    Acampora, K. Bethany
    Nagatomi, Jiro
    Langan, Eugene M., III
    LaBerge, Martine
    [J]. ANNALS OF VASCULAR SURGERY, 2010, 24 (01) : 116 - 126
  • [2] Coated scents for the prevention of restenosis: Part II
    Babapulle, MN
    Eisenberg, MJ
    [J]. CIRCULATION, 2002, 106 (22) : 2859 - 2866
  • [3] Smooth Muscle Cells Orchestrate the Endothelial Cell Response to Flow and Injury
    Balcells, Mercedes
    Martorell, Jordi
    Olive, Carla
    Santacana, Marina
    Chitalia, Vipul
    Cardoso, Angelo A.
    Edelman, Elazer R.
    [J]. CIRCULATION, 2010, 121 (20) : 2192 - U67
  • [4] Atrophic remodeling of the artery-cuffed artery
    Bayer, IM
    Adamson, SL
    Langille, BL
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1999, 19 (06) : 1499 - 1505
  • [5] Effects of stent design parameters on normal artery wall mechanics
    Bedoya, Julian
    Meyer, Clark A.
    Timmins, Lucas H.
    Moreno, Michael R.
    Moore, James E., Jr.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (05): : 757 - 765
  • [6] Hemodynamics and wall mechanics of a compliance matching stent: In vitro and in vivo analysis
    Berry, JL
    Manoach, E
    Mekkaoui, C
    Rolland, PH
    Moore, JE
    Rachev, A
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (01) : 97 - 105
  • [7] Phenotype dictates the growth response of vascular smooth muscle cells to pulse pressure in vitro
    Cappadona, C
    Redmond, EM
    Theodorakis, NG
    McKillop, IH
    Hendrickson, R
    Chhabra, A
    Sitzmann, JV
    Cahill, PA
    [J]. EXPERIMENTAL CELL RESEARCH, 1999, 250 (01) : 174 - 186
  • [8] Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions
    Colombo, A
    Moses, JW
    Morice, MC
    Ludwig, J
    Holmes, DR
    Spanos, V
    Louvard, Y
    Desmedt, B
    Di Mario, C
    Leon, MB
    [J]. CIRCULATION, 2004, 109 (10) : 1244 - 1249
  • [9] A method to develop mock arteries suitable for cell seeding and in-vitro cell culture experiments
    Colombo, A.
    Zahedmanesh, H.
    Toner, D. M.
    Cahill, P. A.
    Lally, C.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2010, 3 (06) : 470 - 477
  • [10] An analysis of the strain field in biaxial Flexcell membranes for different waveforms and frequencies
    Colombo, A.
    Cahill, P. A.
    Lally, C.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H8) : 1235 - 1245