Experimental comparison of two different ilmenites in fluidized bed and fixed bed chemical-looping combustion

被引:28
作者
Schwebel, G. L. [1 ,3 ]
Filippou, D. [2 ]
Hudon, G. [2 ]
Tworkowski, M. [1 ]
Gipperich, A. [1 ]
Krumm, W. [1 ]
机构
[1] Univ Siegen, Inst Energietech, D-57068 Siegen, Germany
[2] Rio Tinto Iron & Titanium, Dept Technol, Sorel Tracy, PQ J3R 1M6, Canada
[3] G Schwebel Dht Envitech, D-35716 Dietzhoelztal, Germany
关键词
Chemical-looping combustion; Rock ilmenite; Fluidized bed; Fixed bed; Sintering; POWER-GENERATION SYSTEM; OXYGEN CARRIERS; OPERATION; DESIGN; FUEL; COAL;
D O I
10.1016/j.apenergy.2013.07.042
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Carbon capture for storage or reuse is seen as one possibility to lower the emissions of anthropogenic CO2. Chemical-looping combustion (CLC) is a promising second generation technique to capture CO2 from thermochemical fuel conversion processes, such as combustion for power generation. The technical implementation of CLC can be conducted using different arrangement approaches based on fluidized or fixed bed reactor designs. When it comes to conversion of solid fuels, the lifetime of an oxygen carrier in a CLC system may be limited by side reactions with fuel ash, or by carryover losses. Therefore, low cost oxygen carriers are preferred. In that context, ilmenite, an iron titanium oxide has been the subject of a number of studies. Here, two ilmenite samples from the Lac Tio mine, Quebec, Canada, extracted from different preparation states were evaluated during activation at 900 degrees C using a CO-CH4-H-2 gas mixture diluted in N-2. The experiments were carried out both under fluidized bed and fixed bed conditions to point out qualitative differences. Generally fixed bed reduction indicated higher gas conversion although coarser particles were used. However, if oxidation is carried out in a fixed bed, particle sintering may be a substantial problem.(C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1902 / 1908
页数:7
相关论文
共 50 条
  • [41] Combustion of Different Type Biopellets in a Fixed - Turbulent Fluidized Bed
    Isemin, Rafail
    Mikhalev, Alexander
    Konyakhin, Valentin
    Kuzmin, Sergey
    Milovanov, Oleg
    Klimov, Dmitry
    INTERNATIONAL SCIENTIFIC CONFERENCE URBAN CIVIL ENGINEERING AND MUNICIPAL FACILITIES (SPBUCEMF-2015), 2015, 117 : 132 - 141
  • [42] A model on chemical looping combustion of methane in a bubbling fluidized-bed process
    Choi, Jeong-Hoo
    Youn, Pil Sang
    Brahimi, Djamila
    Jeon, Young-Wook
    Kim, Sang Done
    Ryu, Ho-Jung
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2012, 29 (06) : 737 - 742
  • [43] A model on chemical looping combustion of methane in a bubbling fluidized-bed process
    Jeong-Hoo Choi
    Pil Sang Youn
    Djamila Brahimi
    Young-Wook Jeon
    Sang Done Kim
    Ho-Jung Ryu
    Korean Journal of Chemical Engineering, 2012, 29 : 737 - 742
  • [44] Comparative study between fluidized-bed and fixed-bed operation modes in pressurized chemical looping combustion of coal
    Zhang, Shuai
    Xiao, Rui
    Zheng, Wenguang
    APPLIED ENERGY, 2014, 130 : 181 - 189
  • [45] Investigation of biomass alkali release in a dual circulating fluidized bed chemical looping combustion system
    Gogolev, Ivan
    Pikkarainen, Toni
    Kauppinen, Juho
    Linderholm, Carl
    Steenari, Britt-Marie
    Lyngfelt, Anders
    FUEL, 2021, 297
  • [46] Chemical looping combustion of coal in a 5 kWth interconnected fluidized bed reactor using hematite as oxygen carrier
    Ma, Jinchen
    Zhao, Haibo
    Tian, Xin
    Wei, Yijie
    Rajendran, Sharmen
    Zhang, Yongliang
    Bhattacharya, Sankar
    Zheng, Chuguang
    APPLIED ENERGY, 2015, 157 : 304 - 313
  • [47] Use of a Chemical-Looping Reaction to Determine the Residence Time Distribution of Solids in a Circulating Fluidized Bed
    Donat, Felix
    Hu, Wenting
    Scott, Stuart A.
    Dennis, John S.
    ENERGY TECHNOLOGY, 2016, 4 (10) : 1230 - 1236
  • [48] Gas leakage properties of chemical looping combustion in interconnected fluidized bed
    Zhang, Siwen
    Wu, Jiahua
    Gu, Haiming
    Shen, Laihong
    Xiao, Jun
    Huagong Xuebao/CIESC Journal, 2012, 63 (07): : 2017 - 2024
  • [49] Experimental investigation of fluidized bed chemical looping combustion of Victorian brown coal using hematite
    Saha, Chiranjib
    Bhattacharya, Sankar
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2014, 2 (03) : 1642 - 1654
  • [50] Model-based analysis of bench-scale fixed-bed units for chemical-looping combustion
    Zhou, Zhiquan
    Han, Lu
    Bollas, George M.
    CHEMICAL ENGINEERING JOURNAL, 2013, 233 : 331 - 348