Role of Navigation in Total Hip Arthroplasty

被引:44
作者
Kelley, Todd C. [1 ]
Swank, Michael L. [2 ]
机构
[1] Univ Cincinnati, Dept Orthopaed, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Cincinnati Orthopaed Res Inst, Cincinnati, OH 45242 USA
关键词
ACETABULAR COMPONENT; IMAGELESS NAVIGATION; CUP; ORIENTATION; ACCURACY; DISLOCATION; PLACEMENT;
D O I
10.2106/JBJS.H.01463
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Current uses of computed tomography-based and imageless navigation systems for total hip arthroplasty include proper placement of the acetabular component, measurement of limb-length changes, enablement of minimally invasive surgery, and proper placement of components for hip resurfacing procedures. This article provides an overview of the rationale for computer-assisted surgery in total hip arthroplasty and hip resurfacing. The experience of the senior author (M.L.S.) with computer-assisted surgery for hip arthroplasty has demonstrated improved position of the acetabular component as compared with the position attainable with use of mechanical instruments, maintenance of appropriate position of the acetabular component during minimally invasive surgery, and appropriate positioning of the femoral and acetabular components during the learning curve for hip resurfacing procedures.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 30 条
[1]   Robots in orthopaedic surgery - Past, present, and future [J].
Bargar, William L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :31-36
[2]   Minimally invasive total hip arthroplasty - Development, early results, and a critical analysis [J].
Berry, DJ ;
Berger, RA ;
Callaghan, JJ ;
Dorr, LD ;
Duwelius, PJ ;
Hartzband, MA ;
Lieberman, JR ;
Mears, DC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2235-2236
[3]  
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[4]   On a method of investigating the deep ganglia and tracts of the central nervous system (Cerebellum) (Reprinted from Br Med J, pg 1799, 1906) [J].
Clarke, R. H. ;
Horsley, Victor .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :3-6
[5]  
CLARKE RH, 1906, BMJ-BRIT MED J, V1, P1799
[6]   Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[7]   Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position [J].
Dorr, Lawrence A. ;
Malik, Aamer ;
Wan, Zhinian ;
Long, William T. ;
Harris, Michael .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :92-99
[8]   Accuracy of intraoperative assessment of acetabular prosthesis placement [J].
Hassan, DM ;
Johnston, GHF ;
Dust, WNC ;
Watson, G ;
Dolovich, AT .
JOURNAL OF ARTHROPLASTY, 1998, 13 (01) :80-84
[9]   Orientation of the acetabular component - A comparison of five navigation systems with conventional surgical technique [J].
Honl, M. ;
Schwieger, K. ;
Salineros, M. ;
Jacobs, J. ;
Morlock, M. ;
Wimmer, M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (10) :1401-1405
[10]   Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement [J].
Jolles, BM ;
Genoud, P ;
Hoffmeyer, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :174-179