摘要
Shock tunnels are important ground test facilities that can generate high-enthalpy flow. Flight velocity at a high Mach number can be simulated for aerodynamic testing of chemically reacting flows. However, the application of these tunnels is limited due to the only milliseconds-long test duration, especially for aerodynamic force measurement using traditional strain gauge balances. This study presents an impulse force-measurement system, which was used for a large-scale test model to measure its drag in a high-enthalpy shock tunnel with an approximately 3-7-ms test time. Force tests were conducted for a cone in the JF-10 high-enthalpy shock tunnel in the Institute of Mechanics, Chinese Academy of Sciences. An integrated design of the impulse force-measurement system was proposed for load measurement over a short duration, for which a recommended design criterion is that the measurement period be a minimum of twice the period corresponding to the lowest natural frequency of the measurement system. The current measurement technique breaks the limitations of the application of the conventional strain gauge balance. As an integrated measuring system, the impulse force-measurement system expands the structural design concept of strain gauge balances. The impulse force-measurement system performed well in the present tests. The test results show differences from the numerical simulations and some data obtained in a conventional wind tunnel. A preliminary analysis was performed on the real gas effects on the aerodynamic force.
引用
收藏
页码:603 / 613
页数:11
相关论文
共 50 条
  • [41] Estimates of echo correlation and measurement bias in acoustic radiation force impulse imaging
    McAleavey, SA
    Nightingale, KR
    Trahey, GE
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (06) : 631 - 641
  • [42] Measurement of impact force for triboluminescent-enhanced composites by modified impulse method
    Frketic, Jolie
    Ariza, Natalia
    Olawale, David
    Okoli, Okenwa
    Dickens, Tarik
    Frazier, Nydeia Bolden
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2016, 35 (11) : 915 - 923
  • [43] Design of Measurement System Hydrostatic Force
    Nugroho, Setyo
    Satwika, Nyoman Ade
    2016 INTERNATIONAL ELECTRONICS SYMPOSIUM (IES), 2016, : 248 - 251
  • [44] A novel variable force ratio test system for force measurement
    Zhang, Jun
    Tian, Yu
    Ren, Zongjin
    Hua, Mei
    Jia, Zhenyuan
    ADVANCES IN MECHANICAL ENGINEERING, 2019, 11 (04)
  • [45] Force transducer system for measurement of ice hockey skating force
    Stidwill T.J.
    Turcotte R.A.
    Dixon P.
    Pearsall D.J.
    Sports Engineering, 2009, 12 (2) : 63 - 68
  • [46] Force calibration for an endovascular robotic system with proximal force measurement
    Sankaran, Naveen Kumar
    Chembrammel, Pramod
    Kesavadas, Thenkurussi
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (02):
  • [47] Evaluation of the Force Sensitive Application Hand Force Measurement System
    Jung, Kihyo
    You, Heecheon
    Kwon, Ochae
    HUMAN FACTORS AND ERGONOMICS IN MANUFACTURING & SERVICE INDUSTRIES, 2010, 20 (03) : 226 - 232
  • [48] An integrate ultrasound system for Intravascular Acoustic Radiation Force Impulse Imaging
    Yu, Can
    Ye, Lei
    Xiao, Xin
    Wang, Junjie
    Li, Jian
    Zhang, Hui
    Wang, Zhuochen
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [49] EFFICACY OF LIVER STIFFNESS MEASUREMENT USING ACOUSTIC RADIATION FORCE IMPULSE IN COMPARISON WITH FIBROSCAN
    Saito, Hidetsugu
    Ebinuma, Hirotoshi
    Ojiro, Keisuke
    Cho, Hakusyo
    Umeda, Rumiko
    Usui, Shingo
    Yamagishi, Yoshiyuki
    Wakabayashi, Kanji
    Nakamoto, Nobuhiro
    Hibi, Toshifumi
    HEPATOLOGY, 2009, 50 (04) : 742A - 742A
  • [50] OPTICAL-FIBER IMPULSE-RESPONSE MEASUREMENT SYSTEM
    DANNWOLF, JW
    GOTTFRIED, S
    SARGENT, GA
    STRUM, RC
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1976, 25 (04) : 401 - 406