Coronary Artery Calcium Scoring on Low-dose Prospective Electrocardiographically-triggered 64-Slice CT

被引:26
|
作者
Horiguchi, Jun [1 ]
Matsuura, Noriaki [3 ]
Yamamoto, Hideya [2 ]
Kiguchi, Masao [1 ]
Fujioka, Chikako [1 ]
Kitagawa, Toshiro [2 ]
Kohno, Nobuoki [2 ]
Ito, Katsuhide [2 ,3 ]
机构
[1] Hiroshima Univ Hosp, Dept Clin Radiol, Minami Ku, Hiroshima 7348551, Japan
[2] Hiroshima Univ, Grad Sch Biomed Sci, Programs Appl Biomed, Dept Mol & Internal Med,Div Clin Med Sci, Hiroshima, Japan
[3] Hiroshima Univ, Grad Sch Biomed Sci, Programs Appl Biomed, Dept Radiol,Div Med Intelligence, Hiroshima, Japan
关键词
CT; coronary artery; calcium; radiation dose; interscan variability; interobserver variability; MULTIDETECTOR ROW CT; ULTRAFAST COMPUTED-TOMOGRAPHY; ELECTRON-BEAM TOMOGRAPHY; IN-VITRO-ASSESSMENT; INTERSCAN VARIABILITY; CARDIAC CT; QUANTIFICATION; CALCIFICATION; REPRODUCIBILITY; DISEASE;
D O I
10.1016/j.acra.2008.05.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this prospective study was to assess image noise and variability in repeated coronary artery calcium (CAC) scoring on low-dose prospective electrocardiographically-triggered 64-slice multidetector computed tomography. Materials and Methods. Patients (n = 115) suspected of having coronary artery disease were scanned twice, using a tube current of 10 X body mass index mA. The standard deviation (SD) of the Computed tomographic value in the ascending aorta and (mean + 2 X SD) were obtained. Repeated CAC scores (Agatston, Volume, and mass) were measured by two observers, and the interscan and interobserver variability were determined. Results. The mean tube current used was 246 +/- 36 mA. The mean tube current-time product and mean estimated effective dose were 57 +/- 8 mA and 0.9 +/- 0.2 mSv, respectively. The SD and (mean + 2 X SD) Computed tomographic values in the ascending aorta were 16 +/- 3 and 75 +/- 10 Hounsfield units, respectively. Repeated CAC scores were correlated (r(2) = 0.995-0.998). The interscan variability for observer I and observer 2, respectively, were 13% and 13% for Agatston score, 12% and 11% for volume, and 11% and 11% for mass. The interobserver variability for scan I and scan 2, respectively, were 3% and 3% for Agatston score, 5% and 3% for volume, and 3% and 3% for mass. Conclusion. Low-dose prospective electrocardiographically-triggered 64-slice multidetector computed tomography shows low interscan and interobserver variability on CAC scoring while maintaining low image noise.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 50 条
  • [21] Low-dose coronary calcium scoring CT using a dedicated reconstruction filter for kV-independent calcium measurements
    Jubran, Ayman
    Mastrodicasa, Domenico
    van Praagh, Gijs D.
    Willemink, Martin J.
    Kino, Aya
    Wang, Jia
    Fleischmann, Dominik
    Nieman, Koen
    EUROPEAN RADIOLOGY, 2022, 32 (06) : 4225 - 4233
  • [22] Radiation dose exposure of computed tomography coronary angiography: comparison of dual-source, 16-slice and 64-slice CT
    Rixe, J.
    Conradi, G.
    Rolf, A.
    Schmermund, A.
    Magedanz, A.
    Erkapic, D.
    Deetjen, A.
    Hamm, C. W.
    Dill, T.
    HEART, 2009, 95 (16) : 1337 - 1342
  • [23] Reduction of radiation dose estimates in cardiac 64-slice CT angiography in patients after coronary artery bypass graft surgery
    Hermann, Franziska
    Martinoff, Stefan
    Meyer, Tanja
    Hadamitzky, Martin
    Jiang, Chaohui
    Hendrich, Eva
    Hausleiter, Joerg
    INVESTIGATIVE RADIOLOGY, 2008, 43 (04) : 253 - 260
  • [24] The Future of Concurrent Automated Coronary Artery Calcium Scoring on Screening Low-Dose Computed Tomography
    Waltz, Jeffrey
    Kocher, Madison
    Kahn, Jacob
    Dirr, McKenzie
    Burt, Jeremy R.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (06)
  • [25] Deep convolutional neural networks for automatic coronary calcium scoring in a screening study with low-dose chest CT
    Lessmann, Nikolas
    Isgum, Ivana
    Setio, Arnaud A. A.
    de Vos, Bob D.
    Ciompi, Francesco
    de Jong, Pim A.
    Oudkerk, Matthijs
    Mali, Willem P. Th. M.
    Viergever, Max A.
    van Ginneken, Bram
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [26] 64-Slice spiral double-low CT to evaluate the degree of stenosis and plaque composition in diagnosing coronary artery disease
    Feng, Xiao-Rong
    Liang, Li-Hua
    Wu, Ju-Fang
    Chen, Yao-Qiang
    Liang, Shuang
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (04) : 3088 - 3092
  • [27] High-quality low-dose cardiovascular computed tomography (CCT) in pediatric patients using a 64-slice scanner
    Cannao, Paola Maria
    Secchi, Francesco
    Ali, Marco
    D'Angelo, Ida Daniela
    Scarabello, Marco
    Di Leo, Giovanni
    Sardanelli, Francesco
    ACTA RADIOLOGICA, 2018, 59 (10) : 1247 - 1253
  • [28] Enhancing Radiation Dose Efficiency in Prospective ECG-Triggered Coronary CT Angiography Using Calcium-Scoring CT
    Hagar, Muhammad Taha
    Soschynski, Martin
    Benndorf, Matthias
    Stein, Thomas
    Taron, Jana
    Schlett, Christopher L.
    Bamberg, Fabian
    Krauss, Tobias
    DIAGNOSTICS, 2023, 13 (12)
  • [29] Automatic Coronary Calcium Scoring in Low-Dose Chest Computed Tomography
    Isgum, Ivana
    Prokop, Mathias
    Niemeijer, Meindert
    Viergever, Max A.
    van Ginneken, Bram
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (12) : 2322 - 2334
  • [30] Automatic coronary calcium scoring in low-dose non-ECG-synchronized thoracic CT scans
    Isgum, Ivana
    Prokop, Mathias
    Jacobs, Peter C.
    Gondrie, Martijn J.
    Mali, Willem P. Th. M.
    Viergever, Max A.
    van Ginneken, Bram
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624