Coronary Artery Calcium Scoring on Low-dose Prospective Electrocardiographically-triggered 64-Slice CT

被引:26
作者
Horiguchi, Jun [1 ]
Matsuura, Noriaki [3 ]
Yamamoto, Hideya [2 ]
Kiguchi, Masao [1 ]
Fujioka, Chikako [1 ]
Kitagawa, Toshiro [2 ]
Kohno, Nobuoki [2 ]
Ito, Katsuhide [2 ,3 ]
机构
[1] Hiroshima Univ Hosp, Dept Clin Radiol, Minami Ku, Hiroshima 7348551, Japan
[2] Hiroshima Univ, Grad Sch Biomed Sci, Programs Appl Biomed, Dept Mol & Internal Med,Div Clin Med Sci, Hiroshima, Japan
[3] Hiroshima Univ, Grad Sch Biomed Sci, Programs Appl Biomed, Dept Radiol,Div Med Intelligence, Hiroshima, Japan
关键词
CT; coronary artery; calcium; radiation dose; interscan variability; interobserver variability; MULTIDETECTOR ROW CT; ULTRAFAST COMPUTED-TOMOGRAPHY; ELECTRON-BEAM TOMOGRAPHY; IN-VITRO-ASSESSMENT; INTERSCAN VARIABILITY; CARDIAC CT; QUANTIFICATION; CALCIFICATION; REPRODUCIBILITY; DISEASE;
D O I
10.1016/j.acra.2008.05.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this prospective study was to assess image noise and variability in repeated coronary artery calcium (CAC) scoring on low-dose prospective electrocardiographically-triggered 64-slice multidetector computed tomography. Materials and Methods. Patients (n = 115) suspected of having coronary artery disease were scanned twice, using a tube current of 10 X body mass index mA. The standard deviation (SD) of the Computed tomographic value in the ascending aorta and (mean + 2 X SD) were obtained. Repeated CAC scores (Agatston, Volume, and mass) were measured by two observers, and the interscan and interobserver variability were determined. Results. The mean tube current used was 246 +/- 36 mA. The mean tube current-time product and mean estimated effective dose were 57 +/- 8 mA and 0.9 +/- 0.2 mSv, respectively. The SD and (mean + 2 X SD) Computed tomographic values in the ascending aorta were 16 +/- 3 and 75 +/- 10 Hounsfield units, respectively. Repeated CAC scores were correlated (r(2) = 0.995-0.998). The interscan variability for observer I and observer 2, respectively, were 13% and 13% for Agatston score, 12% and 11% for volume, and 11% and 11% for mass. The interobserver variability for scan I and scan 2, respectively, were 3% and 3% for Agatston score, 5% and 3% for volume, and 3% and 3% for mass. Conclusion. Low-dose prospective electrocardiographically-triggered 64-slice multidetector computed tomography shows low interscan and interobserver variability on CAC scoring while maintaining low image noise.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 25 条
[1]   Variability of repeated coronary artery calcium measurements by electron beam tomography [J].
Achenbach, S ;
Ropers, D ;
Möhlenkamp, S ;
Schmermund, A ;
Muschiol, G ;
Groth, J ;
Kusus, M ;
Regenfus, M ;
Daniel, WG ;
Erbel, R ;
Moshage, W .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :210-+
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]   SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE [J].
BIELAK, LF ;
KAUFMANN, RB ;
MOLL, PP ;
MCCOLLOUGH, CH ;
SCHWARTZ, RS ;
SHEEDY, PF .
RADIOLOGY, 1994, 192 (03) :631-636
[4]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[5]   Detection and quantification of coronary calcification: An update. [J].
Fischbach, R ;
Heindel, W .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (05) :407-414
[6]   ACCF/AHA 2007 Clinical Expert Consensus document on coronary artery calcium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain [J].
Greenland, Philip ;
Bonow, Robert O. ;
Brundage, Bruce H. ;
Budoff, Matthew J. ;
Eisenberg, Mark J. ;
Grundy, Scott M. ;
Lauer, Michael S. ;
Post, Wendy S. ;
Raggi, Paolo ;
Redberg, Rita F. ;
Rodgers, George P. ;
Shaw, Leslee J. ;
Taylor, Allen J. ;
Weintraub, William S. ;
Harrington, Robert A. ;
Abrams, Jonathan ;
Anderson, Jeffrey L. ;
Bates, Eric R. ;
Eisenberg, Mark J. ;
Grines, Cindy L. ;
Hlatky, Mark A. ;
Lichtenberg, Robert C. ;
Lindner, Jonathan R. ;
Pohost, Gerald M. ;
Schofield, Richard S. ;
Shubrooks, Samuel J., Jr. ;
Stein, James H. ;
Tracy, Cynthia M. ;
Vogel, Robert A. ;
Wesley, Deborah J. ;
Lewin, John C. ;
Arend, Thomas E., Jr. ;
Bradfield, Lisa ;
Velasquez, Maria ;
Barrett, Erin A. ;
Christiansen, Peg .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (03) :378-402
[7]   Potential clinical impact of variability in the measurement of coronary artery calcification with sequential MDCT [J].
Halliburton, SS ;
Stillman, AE ;
Lieber, M ;
Kasper, JM ;
Kuzmiak, SA ;
White, RD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) :643-648
[8]   Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose [J].
Hong, C ;
Bae, KT ;
Pilgram, TK ;
Suh, J ;
Bradley, D .
RADIOLOGY, 2002, 225 (03) :901-906
[9]   Timing on 16-slice scanner and implications for 64-slice cardiac CT: Do you start scanning immediately after breath hold? [J].
Horiguchi, J ;
Shen, Y ;
Hirai, N ;
Yamamoto, H ;
Akiyama, Y ;
Ishifuro, M ;
Kakizawa, H ;
Hieda, M ;
Tachikake, T ;
Matsuura, N ;
Ito, K .
ACADEMIC RADIOLOGY, 2006, 13 (02) :173-176
[10]   Variability of repeated coronary artery calcium measurements by 16-MDCT with retrospective reconstruction [J].
Horiguchi, J ;
Yamamoto, H ;
Akiyama, Y ;
Hirai, N ;
Marukawa, K ;
Fukuda, H ;
Ito, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (06) :1917-1923