Clinical Evaluation of a Novel Preloaded Intraocular Lens Delivery System During Routine Cataract Surgery

被引:4
作者
Black, Daniel [1 ]
Corbett, Dean [2 ]
Roberts, Timothy V. [3 ,4 ]
Cronin, Brendan [5 ]
Smith, Pamela J. [6 ]
Janakiraman, D. Priya [6 ]
Jackson, Beth E. [6 ]
机构
[1] Sunshine Eye Clin, Birtinya, Qld, Australia
[2] Auckland Eye Ltd, Auckland, New Zealand
[3] Univ Sydney, Sydney Med Sch, Sydney, NSW, Australia
[4] Vis Eye Inst, Sydney, NSW, Australia
[5] Queensland Eye Inst, South Brisbane, Qld, Australia
[6] Johnson & Johnson Surg Vis Inc, Santa Ana, CA USA
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
cataract surgery; IOL; preloaded delivery system; clinical handleability; IOL IMPLANTATION; INCISION SIZE; INJECTOR; ENDOPHTHALMITIS; MICROINCISION; PERFORMANCE; SURFACE;
D O I
10.2147/OPTH.S260925
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical handleability and acceptability of a novel preloaded intraocular lens (IOL) delivery system for implantation of the TECNIS ZCB00 IOL (Johnson & Johnson Surgical Vision, Inc., Santa Ana, CA, USA) during routine small-incision cataract surgery. Subjects and Methods: In this prospective, open-label, noncomparative, unilateral or bilateral, multicenter study, adult subjects with unilateral or bilateral cataracts scheduled for IOL implantation were enrolled. Surgeons and surgical technicians completed per-eye day-of-surgery and end-of-surgical-day questionnaires. The primary endpoint of the study was the rate of acceptable overall clinical performance of the preloaded IOL delivery system. Other endpoints included additional responses from the questionnaires, preimplantation incision size, and safety. Results: The study included 91 eyes that underwent cataract surgery and IOL implantation using the preloaded delivery system and were available for the 1-day postoperative visit. Five surgeons and 14 surgical technicians from four investigational sites participated in the study. The rate of acceptable overall clinical performance was 100% (91/91) of eyes, with most responses (78/91; 85.7%) being the highest possible rating of 5 (very satisfied). Favorable responses by most surgeons and surgical technicians regarding additional endpoints further highlighted the handleability and acceptability of the preloaded delivery system. No ocular adverse events or lens findings (ie, no cases of IOL instability, haptic breakage, IOL marking, or crimping) were reported. Conclusion: The results of this study demonstrated that this preloaded IOL delivery system was safe and effective during routine small-incision cataract surgery.
引用
收藏
页码:2291 / 2300
页数:10
相关论文
共 50 条
  • [31] Influence of intraocular lens material on the development of acute endophthalmitis after cataract surgery?
    Kodjikian, L.
    Beby, F.
    Rabilloud, M.
    Bruslea, D.
    Halphen, I.
    Fleury, J.
    Grange, J-D
    Garweg, J. G.
    EYE, 2008, 22 (02) : 184 - 193
  • [32] Influence of intraocular lens material on the development of acute endophthalmitis after cataract surgery?
    L Kodjikian
    F Beby
    M Rabilloud
    D Bruslea
    I Halphen
    J Fleury
    J-D Grange
    J G Garweg
    Eye, 2008, 22 : 184 - 193
  • [33] Outcome of cataract surgery with primary intraocular lens implantation in children
    Ram, Jagat
    Gupta, Nishant
    Sukhija, Jaspreet Singh
    Chaudhary, Manish
    Verma, Neelam
    Kumar, Sunil
    Severia, Saurabh
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (08) : 1086 - 1090
  • [34] Optical quality of toric intraocular lens implantation in cataract surgery
    Xiao, Xian-Wen
    Hao, Jing
    Zhang, Hong
    Tian, Fang
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (01) : 66 - 71
  • [35] TORIC INTRAOCULAR LENS IMPLANTATION FOR ASTIGMATISM CORRECTION IN CATARACT SURGERY
    Vickovic, Ivanka Petric
    Loncar, Valentina Lacmanovic
    Mandic, Zdravko
    Ivekovic, Renata
    Herman, Jelena Skunca
    Sesar, Antonio
    ACTA CLINICA CROATICA, 2012, 51 (02) : 293 - 297
  • [36] Clinical features and outcomes of congenital cataract surgery with primary intraocular lens implantation in a tunisian cohort
    Malek, Ines
    Sayadi, Jihene
    Sammouda, Takwa
    Choura, Racem
    Mekni, Manel
    Zghal, Imen
    Khairallah, Moncef
    Nacef, Leila
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2022, 34 (02): : 187 - 193
  • [37] Challenges during femtosecond laser assisted cataract surgery with posterior chamber phakic intraocular lens
    Nath, Manas
    Gireesh, Prasanth
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1744 - +
  • [38] Computer-Aided Intraoperative Toric Intraocular Lens Positioning and Alignment During Cataract Surgery
    Zhai, Yuxuan
    Zhang, Guanghua
    Zheng, Longsheng
    Yang, Guangqian
    Zhao, Ke
    Gong, Yubin
    Zhang, Zhe
    Zhang, Ximei
    Sun, Bin
    Wang, Zhao
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (10) : 3921 - 3932
  • [39] Sustained Antibiotic Release from an Intraocular Lens-Hydrogel Assembly for Cataract Surgery
    Garty, Shai
    Shirakawa, Rika
    Warsen, Adelaide
    Anderson, Erin M.
    Noble, Misty L.
    Bryers, James D.
    Ratner, Buddy D.
    Shen, Tueng. T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (09) : 6109 - 6116
  • [40] A Critical Appraisal of New Developments in Intraocular Lens Modifications and Drug Delivery Systems for the Prevention of Cataract Surgery Complications
    Mylona, Ioanna
    Tsinopoulos, Ioannis
    PHARMACEUTICALS, 2020, 13 (12) : 1 - 25