Recent Progress in Electrochemical pH-Sensing Materials and Configurations for Biomedical Applications

被引:194
作者
Ghoneim, M. T. [1 ]
Nguyen, A. [4 ]
Dereje, N. [2 ]
Huang, J. [3 ]
Moore, G. C. [5 ]
Murzynowski, P. J. [6 ]
Dagdeviren, C. [1 ]
机构
[1] MIT, MIT Media Lab, Cambridge, MA 02139 USA
[2] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[3] MIT, Dept Aeronaut & Astronaut, Cambridge, MA 02139 USA
[4] MIT, Dept Biol Engn, Cambridge, MA 02142 USA
[5] MIT, Dept Mat Sci & Engn, Cambridge, MA 02142 USA
[6] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02142 USA
关键词
FIELD-EFFECT-TRANSISTOR; ION-SELECTIVE ELECTRODES; MICRO-FLUIDIC PLATFORM; OF-THE-ART; IRIDIUM OXIDE; REAL-TIME; THIN-FILM; N-TYPE; EXTRACELLULAR PH; DOUBLE-LAYER;
D O I
10.1021/acs.chemrev.8b00655
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
pH-sensing materials and configurations are rapidly evolving toward exciting new applications, especially those in biomedical applications. In this review, we highlight rapid progress in electrochemical pH sensors over the past decade (20082018) with an emphasis on key considerations, such as materials selection, system configurations, and testing protocols. In addition to recent progress in optical pH sensors, our main focus in this review is on electromechanical pH sensors due to their significant advances, especially in biomedical applications. We summarize developments of electrochemical pH sensors that by virtue of their optimized material chemistries (from metal oxides to polymers) and geometrical features (from thin films to quantum dots) enable their adoption in biomedical applications. We further present an overview of necessary sensing standards and protocols. Standards ensure the establishment of consistent protocols, facilitating collective understanding of results and building on the current state. Furthermore, they enable objective benchmarking of various pH-sensing reports, materials, and systems, which is critical for the overall progression and development of the field. Additionally, we list critical issues in recent literary reporting and suggest various methods for objective benchmarking. pH regulation in the human body and state-of-the-art pH sensors (from ex vivo to in vivo) are compared for suitability in biomedical applications. We conclude our review by (i) identifying challenges that need to be overcome in electrochemical pH sensing and (ii) providing an outlook on future research along with insights, in which the integration of various pH sensors with advanced electronics can provide a new platform for the development of novel technologies for disease diagnostics and prevention.
引用
收藏
页码:5248 / 5297
页数:50
相关论文
共 301 条
  • [11] [Anonymous], IEEE REG 10 C HYD 19
  • [12] Ashton J., 2011, TSP, V1, P1
  • [13] Doping Asymmetry Problem in ZnO: Current Status and Outlook
    Avrutin, Vitaliy
    Silversmith, Donald J.
    Morkoc, Hadis
    [J]. PROCEEDINGS OF THE IEEE, 2010, 98 (07) : 1269 - 1280
  • [14] Synthesis, diffused reflectance and electrical properties of nanocrystalline Fe-doped ZnO via sol-gel calcination technique
    Aydin, C.
    Abd El-sadek, M. S.
    Zheng, Kaibo
    Yahia, I. S.
    Yakuphanoglu, F.
    [J]. OPTICS AND LASER TECHNOLOGY, 2013, 48 : 447 - 452
  • [15] Baliga Sharmila, 2013, J Indian Soc Periodontol, V17, P461, DOI 10.4103/0972-124X.118317
  • [16] Non-invasive wearable electrochemical sensors: a review
    Bandodkar, Amay J.
    Wang, Joseph
    [J]. TRENDS IN BIOTECHNOLOGY, 2014, 32 (07) : 363 - 371
  • [17] Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
    Bandodkar, Amay J.
    Hung, Vinci W. S.
    Jia, Wenzhao
    Valdes-Ramirez, Gabriela
    Windmiller, Joshua R.
    Martinez, Alexandra G.
    Ramirez, Julian
    Chan, Garrett
    Kerman, Kagan
    Wang, Joseph
    [J]. ANALYST, 2013, 138 (01) : 123 - 128
  • [18] Monitoring pH with organic-based field-effect transistors
    Bartic, C
    Palan, B
    Campitelli, A
    Borghs, G
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3) : 115 - 122
  • [19] ZnO extended-gate field-effect transistors as pH sensors -: art. no. 143508
    Batista, PD
    Mulato, M
    [J]. APPLIED PHYSICS LETTERS, 2005, 87 (14) : 1 - 3
  • [20] THE MODERN UNDERSTANDING OF THE GLASS-ELECTRODE RESPONSE
    BAUCKE, FGK