Flocculation Activity of Grafted Chitosan for Water Treatment

被引:0
|
作者
Alatawi, Raedah A. S. [1 ]
Bukhari, Abeer Abdulaziz H. [1 ]
Al-Sayed, Hanan M. A. [2 ,3 ]
Faridi, U. . [4 ]
Khali, S. A. [5 ]
Mohamed, Wael S. [6 ]
机构
[1] Univ Tabuk, Fac Sci, Dept Chem, Tabuk 71421, Saudi Arabia
[2] Univ Tabuk, Fac Home Econ, Dept Nutr & Food Sci, Tabuk, Saudi Arabia
[3] Ain Shams Univ, Fac Agr, Food Sci Dept, Cairo, Egypt
[4] Univ Tabuk, Fac Sci, Biochem Dept, Tabuk 71421, Saudi Arabia
[5] Univ Tabuk, Alwajh Coll, Chem Dept, Tabuk, Saudi Arabia
[6] Natl Res Ctr, Polymers Dept, Cairo, Egypt
来源
EGYPTIAN JOURNAL OF CHEMISTRY | 2022年 / 65卷 / 12期
关键词
Type your keywords here; separated by semicolons; REMOVAL; STARCH;
D O I
10.21608/EJCHEM.2022.119028.5352
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Chitosan was grafted with 2-(dimethylamino) ethyl methacrylate monomer, or with 2-(dimethylamine) ethyl methacrylate-acrylic acid monomers. The obtained chitosan poly 2-(dimethylamine) ethyl methacrylate (I) as well as Chitosan poly-2-(dimethylamine) ethyl methacrylate-acrylic acid (II) hybrids were evaluated in flocculation performance of kaolin suspension and also in the clarification behavior of treated tap water when combined with alum. The polymerization was carried out using potassium persulphate/sodium bisulphite redox initiation system at 60(O)C for 3 hours. The obtained two grafted samples I and II were characterized using FTIR, thermal properties expressed as thermogravemetric analysis (TGA) and differential scanning calorimeter (DSC) as well as X-ray. The water clarification from kaolin suspension was evaluated for the two obtained hybrid polymers with respect to the pH, polymer dosage, and settling time. The combination between the prepared hybrid and alum was also investigated. The results showed that the grafted chitosan copolymers I & II exhibited thermal stability. The best flocculation for the two prepared hybrid I & II were observed at pH 6.5 and dosage concentration of 1 ppm with recorded turbidity of 3.01 & 2.66 NTU. The best flocculation was observed for native chitosan at pH 7.5 and 4.85 NTU. Combination between 25 ppm alum with 0.5 of each of I & II induced more water clarification with turbidity values of 1.84 & 1.65.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [21] Protocatechuic acid grafted onto chitosan: Characterization and antioxidant activity
    Liu, Jun
    Meng, Chen-guang
    Yan, Ye-hua
    Shan, Ya-na
    Kan, Juan
    Jin, Chang-hai
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2016, 89 : 518 - 526
  • [22] Research Progress of Magnetic Flocculation in Water Treatment
    Hu, Zhihao
    Wu, Kun
    Wang, Zihan
    Shah, Kinjal J.
    Sun, Yongjun
    MAGNETOCHEMISTRY, 2024, 10 (08)
  • [23] A study of titanium sulfate flocculation for water treatment
    Wu, Yi-Fan
    Liu, Wen
    Gao, Nai-Yun
    Tao, Tao
    WATER RESEARCH, 2011, 45 (12) : 3704 - 3711
  • [24] FLOCCULATION AS A TREATMENT FOR PETROLEUM REFINERY WASTE WATER
    HART, WB
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1957, 49 (05): : A77 - &
  • [25] Critical elements of flocculation in drinking water treatment
    Alansari, Amir
    Amburgey, James
    AWWA WATER SCIENCE, 2020, 2 (06):
  • [26] Numerical simulation of mechanical flocculation in water treatment
    Zhan, Minshu
    You, Minghao
    Liu, Lingling
    Zhang, Yilin
    Yuan, Fang
    Guo, Baoyu
    Cheng, Guojian
    Xu, Wei
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (04):
  • [27] Insight into flocculation mechanism of chitosan
    Chen, Liang
    Chen, Dong-Hui
    Wu, Chong-Liang
    2003, Editorial Board of Journal of Dong Hua University (20):
  • [28] Flocculation of algae using chitosan
    Divakaran, R
    Pillai, VNS
    JOURNAL OF APPLIED PHYCOLOGY, 2002, 14 (05) : 419 - 422
  • [29] Flocculation of algae using chitosan
    Ravi Divakaran
    V.N. Sivasankara Pillai
    Journal of Applied Phycology, 2002, 14 : 419 - 422
  • [30] Flocculation studies based on water-soluble polymers of grafted carboxymethyl cellulose and polyacrylamide
    Biswal, D.R.
    Singh, R.P.
    Journal of Applied Polymer Science, 2006, 102 (02): : 1000 - 1007