Maximum embryo absorbed dose from intravenous urography: Interhospital variations

被引:8
作者
Damilakis, J
Perisinakis, K
Koukourakis, M
Gourtsoyiannis, N
机构
[1] Department of Medical Physics, University of Crete, 711 10 Stavrakia, Iraklion, Crete
[2] Department of Radiology, University of Crete, 711 10 Stavrakia, Iraklion, Crete
[3] Department of Radiotherapy, University Hospital of Iraklion, Iraklion, Crete
关键词
D O I
10.1093/oxfordjournals.rpd.a032079
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study was to determine the maximum embryo dose during intravenous urography (IVU) examinations, when inadvertent irradiation of a pregnant woman occurs, and to investigate the variation of doses received from different institutions. Doses at average embryo depth from IVU examinations have been measured in four institutions, using a Rando phantom and thermoluminescent crystals. In order to estimate the maximum range of embryo doses, radiologists were asked to carry out the examinations with the same technique as in female patients with acute ureteral obstruction. The range of doses estimated at embryo depth for the institutions participating in this study was 5.77 to 35.2 mGy. The considerable interhospital variation found in dose can be explained by different equipment and techniques used. A simple method of estimating embryo dose from pelvic radiographs reported previously was found to be also applicable to IVU examinations. Absorbed dose at 6 sm, the average embryo depth, was found significantly less than 50 mGy.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 10 条
  • [1] A COMPARISON OF DIAGNOSTIC-RADIOLOGY PRACTICE AND PATIENT EXPOSURE IN BRITAIN, FRANCE AND ITALY
    CONTENTO, G
    MALISAN, MR
    PADOVANI, R
    MACCIA, C
    WALL, BF
    SHRIMPTON, PC
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (722) : 143 - 152
  • [2] A PATIENT-EQUIVALENT ATTENUATION PHANTOM FOR ESTIMATING PATIENT EXPOSURES FROM AUTOMATIC EXPOSURE CONTROLLED X-RAY EXAMINATIONS OF THE ABDOMEN AND LUMBOSACRAL SPINE
    CONWAY, BJ
    DUFF, JE
    FEWELL, TR
    JENNINGS, RJ
    ROTHENBERG, LN
    FLEISCHMAN, RC
    [J]. MEDICAL PHYSICS, 1990, 17 (03) : 448 - 453
  • [3] GALZADO A, 1991, BRIT J RADIOL, V64, P539
  • [4] SOMATIC DOSE INDEX FOR DIAGNOSTIC RADIOLOGY
    LAWS, PW
    ROSENSTEIN, M
    [J]. HEALTH PHYSICS, 1978, 35 (05): : 629 - 642
  • [5] *NCRP, 1994, CONS REG UN RAD EXP
  • [6] PATIENT DOSES AND RISKS FROM DIAGNOSTIC-RADIOLOGY IN NORTHEAST ITALY
    PADOVANI, R
    CONTENTO, G
    FABRETTO, M
    MALISAN, MR
    BARBINA, V
    GOZZI, G
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (710) : 155 - 165
  • [7] Plaut S., 1993, RAD PROTECTION XRAY
  • [8] ESTIMATION AND MINIMIZATION OF FETAL ABSORBED DOSE - DATA FROM COMMON RADIOGRAPHIC EXAMINATIONS
    RAGOZZINO, MW
    GRAY, JE
    BURKE, TM
    VANLYSEL, MS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (04) : 667 - 671
  • [9] AVERAGE FETAL DEPTH INUTERO - DATA FOR ESTIMATION OF FETAL ABSORBED RADIATION-DOSE
    RAGOZZINO, MW
    BRECKLE, R
    HILL, LM
    GRAY, JE
    [J]. RADIOLOGY, 1986, 158 (02) : 513 - 515
  • [10] DOSES TO PATIENTS FROM ROUTINE DIAGNOSTIC-X-RAY EXAMINATIONS IN ENGLAND
    SHRIMPTON, PC
    WALL, BF
    JONES, DG
    FISHER, ES
    HILLIER, MC
    KENDALL, GM
    HARRISON, IRM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704) : 749 - 758