Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration

被引:24
作者
Ellis, R
ToksvigLarsen, S
Marcacci, M
Caramella, D
Fadda, M
机构
[1] UNIV LUND HOSP,DEPT ORTHOPAED SURG,S-22185 LUND,SWEDEN
[2] RIZZOLI ORTHOPAED INST,BIOMECH LAB,BOLOGNA,ITALY
关键词
registration; validation; computed tomography; computer-assisted surgery;
D O I
10.1097/00004424-199610000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Accurate registration of computed tomography (CI) images to the patient is crucial for computer-assisted surgery, Markers used in roentgen stereo-grammetric analysis (RSA) can be located in a CT scan using a novel approach and also can be located physically, Roentgen stereo-grammetric analysis data act as ''ground truth'' for the three-dimensional marker locations. METHODS. Two foam-bone phantoms were marked, The markers were scanned seven times with RSA, three times with axial CT, and contacted four times with a coordinate measuring arm, Root-mean-square (RMS) errors were derived for the registrations. RESULTS. Computed tomography and RSA data register to 0.15 mm RMS error, Computed tomography and arm data register to 0.25 mm, The markers are biocompatible, and the coordinate measuring arm is usable in an operating room. CONCLUSIONS. Typical in vitro registration errors are approximately 2 mm, The authors have developed a marker that provides superior registration, and a procedure that can be used for in vivo studies.
引用
收藏
页码:658 / 667
页数:10
相关论文
共 50 条
  • [41] Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    Kitamura, K
    Shirato, H
    Shimizu, S
    Shinohara, N
    Harabayashi, T
    Shimizu, T
    Kodama, Y
    Endo, H
    Onimaru, R
    Nishioka, S
    Aoyama, H
    Tsuchiya, K
    Miyasaka, K
    RADIOTHERAPY AND ONCOLOGY, 2002, 62 (03) : 275 - 281
  • [42] How to obtain high-accuracy image registration: application to movement correction of dynamic positron emission tomography data
    Andersson, JLR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (06) : 575 - 586
  • [43] Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography
    Solomon, Justin
    Samei, Ehsan
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (03)
  • [44] Spatial resolution measurement for iterative reconstruction by use of image-averaging techniques in computed tomography
    Urikura A.
    Ichikawa K.
    Hara T.
    Nishimaru E.
    Nakaya Y.
    Radiological Physics and Technology, 2014, 7 (2) : 358 - 366
  • [45] IMAGE FUSION OF REAL-TIME ULTRASONOGRAPHY WITH COMPUTED TOMOGRAPHY: FACTORS AFFECTING THE REGISTRATION ERROR AND MOTION OF FOCAL HEPATIC LESIONS
    Lee, Min Woo
    Park, Hyun Jeong
    Kang, Tae Wook
    Ryu, Jiwon
    Bang, Won-Chul
    Lee, Bora
    Lee, Eun Sun
    Choi, Byung Ihn
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (09) : 2024 - 2032
  • [46] Usage of image registration and three-dimensional visualization tools on serial computed tomography for the analysis of patients with traumatic intraparenchymal hemorrhages
    Shih, Yun-Ju
    Liu, Yan-Lin
    Zhou, Jonathan T.
    Zhang, Yang
    Chen, Jeon-Hor
    Chen, Tai-Yuan
    Yang, Cheng-Chun
    Su, Min-Ying
    JOURNAL OF CLINICAL NEUROSCIENCE, 2022, 98 : 154 - 161
  • [47] Use and uncertainties of mutual information for computed tomography/magnetic resonance (CT/MR) registration post permanent implant of the prostate
    Roberson, PL
    McLaughlin, PW
    Narayana, V
    Troyer, S
    Hixson, GV
    Kessler, ML
    MEDICAL PHYSICS, 2005, 32 (02) : 473 - 482
  • [48] Integration accuracy of craniofacial cone-beam computed tomography images with three-dimensional facial scans according to different registration areas
    Aljawad, Hussein
    Kang, Nara
    Lee, Kyungmin Clara
    ANGLE ORTHODONTIST, 2023, 93 (01) : 66 - 70
  • [49] Effects of Lung Injury on Regional Aeration and Expiratory Time Constants: Insights From Four-Dimensional Computed Tomography Image Registration
    Herrmann, Jacob
    Gerard, Sarah E.
    Shao, Wei
    Xin, Yi
    Cereda, Maurizio
    Reinhardt, Joseph M.
    Christensen, Gary E.
    Hoffman, Eric A.
    Kaczka, David W.
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [50] In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration
    Han, Gaofeng
    Li, Jing
    Wang, Shuo
    Liu, Yan
    Wang, Xuedong
    Zhou, Yanheng