Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration

被引:24
作者
Ellis, R
ToksvigLarsen, S
Marcacci, M
Caramella, D
Fadda, M
机构
[1] UNIV LUND HOSP,DEPT ORTHOPAED SURG,S-22185 LUND,SWEDEN
[2] RIZZOLI ORTHOPAED INST,BIOMECH LAB,BOLOGNA,ITALY
关键词
registration; validation; computed tomography; computer-assisted surgery;
D O I
10.1097/00004424-199610000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Accurate registration of computed tomography (CI) images to the patient is crucial for computer-assisted surgery, Markers used in roentgen stereo-grammetric analysis (RSA) can be located in a CT scan using a novel approach and also can be located physically, Roentgen stereo-grammetric analysis data act as ''ground truth'' for the three-dimensional marker locations. METHODS. Two foam-bone phantoms were marked, The markers were scanned seven times with RSA, three times with axial CT, and contacted four times with a coordinate measuring arm, Root-mean-square (RMS) errors were derived for the registrations. RESULTS. Computed tomography and RSA data register to 0.15 mm RMS error, Computed tomography and arm data register to 0.25 mm, The markers are biocompatible, and the coordinate measuring arm is usable in an operating room. CONCLUSIONS. Typical in vitro registration errors are approximately 2 mm, The authors have developed a marker that provides superior registration, and a procedure that can be used for in vivo studies.
引用
收藏
页码:658 / 667
页数:10
相关论文
共 50 条
  • [31] Evaluation of computed tomography settings in the context of visualization and discrimination of low dose injections of a novel liquid soft tissue fiducial marker in head and neck imaging
    David Steybe
    Philipp Poxleitner
    Pit Jacob Voss
    Marc Christian Metzger
    Rainer Schmelzeisen
    Fabian Bamberg
    Suam Kim
    Maximilian Frederik Russe
    BMC Medical Imaging, 21
  • [32] Computed tomography with image intensifier: potential use for nondestructive testing and imaging of small objects
    Rao, DV
    Cesareo, R
    Brunetti, A
    Gigante, GE
    NDT & E INTERNATIONAL, 2000, 33 (08) : 523 - 530
  • [33] Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration
    Parker, CC
    Damyanovich, A
    Haycocks, T
    Haider, M
    Bayley, A
    Catton, CN
    RADIOTHERAPY AND ONCOLOGY, 2003, 66 (02) : 217 - 224
  • [34] Accuracy of Postoperative Computed Tomography and Magnetic Resonance Image Fusion for Assessing Deep Brain Stimulation Electrodes
    Thani, Nova B.
    Bala, Arul
    Swann, Gary B.
    Lind, ChristopherR. P.
    NEUROSURGERY, 2011, 69 (01) : 207 - 214
  • [35] Evaluation of computed tomography settings in the context of visualization and discrimination of low dose injections of a novel liquid soft tissue fiducial marker in head and neck imaging
    Steybe, David
    Poxleitner, Philipp
    Voss, Pit Jacob
    Metzger, Marc Christian
    Schmelzeisen, Rainer
    Bamberg, Fabian
    Kim, Suam
    Russe, Maximilian Frederik
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [36] Use of computed tomography image processing for mapping of human cervical facet surface geometry
    Onan, OA
    Hipp, JA
    Heggeness, MH
    MEDICAL ENGINEERING & PHYSICS, 1998, 20 (01) : 77 - 81
  • [37] The accuracy of 3D fluoroscopy (XT) vs computed tomography (CT) registration in deep brain stimulation (DBS) surgery
    Matthew D. Cooper
    Carlos Restrepo
    Ron Hill
    Murray Hong
    Ryan Greene
    Lutz M. Weise
    Acta Neurochirurgica, 2020, 162 : 1871 - 1878
  • [38] Automatic registration of pelvic computed tomography data and magnetic resonance scans including a dull circle method for quantitative accuracy evaluation
    van Herk, M
    de Munck, JC
    Lebesque, JV
    Muller, S
    Rasch, C
    Touw, A
    MEDICAL PHYSICS, 1998, 25 (10) : 2054 - 2067
  • [39] The accuracy of 3D fluoroscopy (XT) vs computed tomography (CT) registration in deep brain stimulation (DBS) surgery
    Cooper, Matthew D.
    Restrepo, Carlos
    Hill, Ron
    Hong, Murray
    Greene, Ryan
    Weise, Lutz M.
    ACTA NEUROCHIRURGICA, 2020, 162 (08) : 1871 - 1878
  • [40] Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
    Haiter-Neto, F.
    Wenzel, A.
    Gotfredsen, E.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (01) : 18 - 22