Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration

被引:24
|
作者
Ellis, R
ToksvigLarsen, S
Marcacci, M
Caramella, D
Fadda, M
机构
[1] UNIV LUND HOSP,DEPT ORTHOPAED SURG,S-22185 LUND,SWEDEN
[2] RIZZOLI ORTHOPAED INST,BIOMECH LAB,BOLOGNA,ITALY
关键词
registration; validation; computed tomography; computer-assisted surgery;
D O I
10.1097/00004424-199610000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Accurate registration of computed tomography (CI) images to the patient is crucial for computer-assisted surgery, Markers used in roentgen stereo-grammetric analysis (RSA) can be located in a CT scan using a novel approach and also can be located physically, Roentgen stereo-grammetric analysis data act as ''ground truth'' for the three-dimensional marker locations. METHODS. Two foam-bone phantoms were marked, The markers were scanned seven times with RSA, three times with axial CT, and contacted four times with a coordinate measuring arm, Root-mean-square (RMS) errors were derived for the registrations. RESULTS. Computed tomography and RSA data register to 0.15 mm RMS error, Computed tomography and arm data register to 0.25 mm, The markers are biocompatible, and the coordinate measuring arm is usable in an operating room. CONCLUSIONS. Typical in vitro registration errors are approximately 2 mm, The authors have developed a marker that provides superior registration, and a procedure that can be used for in vivo studies.
引用
收藏
页码:658 / 667
页数:10
相关论文
共 50 条
  • [1] Accuracy of Fiducial Marker Based Multimodal Image Registration in Image Guided Surgery
    Zhang Hongwei
    Wang Guangzhi
    Ding Hui
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1538 - +
  • [2] Quantifying the accuracy of deformable image registration for cone-beam computed tomography with a physical phantom
    Wu, Richard Y.
    Liu, Amy Y.
    Williamson, Tyler D.
    Yang, Jinzhong
    Wisdom, Paul G.
    Zhu, Xiaorong R.
    Frank, Steven J.
    Fuller, Clifton D.
    Gunn, Gary B.
    Gao, Song
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 92 - 100
  • [3] Image registration of MR and CT images using a frameless fiducial marker system
    Kremser, C
    Plangger, C
    Bosecke, R
    Pallua, A
    Aichner, F
    Felber, SR
    MAGNETIC RESONANCE IMAGING, 1997, 15 (05) : 579 - 585
  • [4] The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry
    Brouwer, Charlotte L.
    Kierkels, Roel G. J.
    van 't Veld, Aart A.
    Sijtsema, Nanna M.
    Meertens, Harm
    RADIATION ONCOLOGY, 2014, 9
  • [5] A Literature Survey of Ultrasound and Computed Tomography-Based Cardiac Image Registration
    Ming, Chieng Thion
    Omar, Zaid
    Mahmood, Nasrul Humaimi
    Kadiman, Suhaini
    JURNAL TEKNOLOGI, 2015, 74 (06): : 93 - 101
  • [6] Validation of accuracy in image co-registration with computed tomography and magnetic resonance imaging in Gamma Knife radiosurgery
    Nakazawa, Hisato
    Mori, Yoshimasa
    Komori, Masataka
    Shibamoto, Yuta
    Tsugawa, Takahiko
    Kobayashi, Tatsuya
    Hashizume, Chisa
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (05) : 924 - 933
  • [7] Evaluating accuracy of cervical spine computed tomography interpretation by emergency trainees with the use of a structured protocol
    Malhotra, Geetika
    Varma, Dinesh
    Mitra, Biswadev
    EMERGENCY MEDICINE AUSTRALASIA, 2025, 37 (01)
  • [8] Computed tomography lung iodine contrast mapping by image registration and subtraction
    Goatman, Keith
    Plakas, Costas
    Schuijf, Joanne
    Beveridge, Erin
    Prokop, Mathias
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [9] Evaluation of percutaneous fiducial marker placement under computed tomography guidance for stereotactic radiotherapy for lung lesions
    Erdal, Mehmet
    Bayrak, Ahmet
    Imamoglu, Cetin
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2025, 16 (01): : 36 - 40
  • [10] An automated, quantitative, and case-specific evaluation of deformable image registration in computed tomography images
    Kierkels, R. G. J.
    den Otter, L. A.
    Korevaar, E. W.
    Langendijk, J. A.
    van der Schaaf, A.
    Knopf, A. C.
    Sijtsema, N. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (04)