Investigating the effect of duct burner fuel mass flow rate on exergy destruction of a real combined cycle power plant components based on advanced exergy analysis

被引:30
作者
Boyaghchi, Fateme Ahmadi [1 ]
Molaie, Hanieh [1 ]
机构
[1] Alzahra Univ, Fac Engn & Technol, Dept Mech Engn, Tehran, Iran
关键词
Advanced exergy; Combined cycle power plant; Duct burner; Parametric study; Avoidable/unavoidable exergy destruction; ELECTRICITY-GENERATING FACILITY; THERMOECONOMIC OPTIMIZATION; IRREVERSIBILITY; COSTS;
D O I
10.1016/j.enconman.2015.07.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this research, an advanced exergy analysis of a real combined cycle power plant (CCPP) with supplementary firing is investigated. The endogenous/exogenous irreversibilities of each component and their combination with avoidable/unavoidable irreversibilities are identified. Furthermore, parametric study of the total exergy destruction, thermal and exergetic efficiencies and different parts of exergy destruction of each component are examined as a function of duct burner fuel mass flow rate ((m) over dot(DB)). It is revealed that the avoidable exergy destruction of CCPP decreases within 23.9% while its unavoidable part increases by about 50% as (m) over dot(DB) increases. In addition, the endogenous avoidable exergy destruction of CCPP gets 3 times while its exogenous part of avoidable is reduced within 86% by increasing film. It is found that the growth of (m) over dot(DB) elevates the potential improvement of high pressure superheater (HP.SUP), low pressure evaporator (LP.EVAP) and low pressure steam turbine (LP.ST), and decreases the avoidable exergy destruction of the high pressure evaporator (HP.EVAP) and duct burner (DB). Moreover, the increment of (m) over dot(DB), decreases the unavoidable exergy destruction just in high pressure steam turbine (HP.ST) and dearator (DEAR) by. about 8.2% and 5%, respectively, and increases the exogenous of avoidable exergy destruction of DB ((E) over dot(D,DB)(AV)) within 166%. It means that the effect of other components irreversibilities on avoidable exergy destruction of DB is increased while inefficiency of this component has considerable decrement on its avoidable exergy destruction. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:827 / 835
页数:9
相关论文
共 28 条
[1]   Advanced exergy analysis of an electricity-generating facility using natural gas [J].
Acikkalp, Emin ;
Aras, Haydar ;
Hepbasli, Arif .
ENERGY CONVERSION AND MANAGEMENT, 2014, 82 :146-153
[2]   Advanced exergoeconomic analysis of an electricity-generating facility that operates with natural gas [J].
Acikkalp, Emin ;
Aras, Haydar ;
Hepbasli, Arif .
ENERGY CONVERSION AND MANAGEMENT, 2014, 78 :452-460
[3]   Exergy, exergoeconomic and environmental analyses and evolutionary algorithm based multi-objective optimization of combined cycle power plants [J].
Ahmadi, Pouria ;
Dincer, Ibrahim ;
Rosen, Marc A. .
ENERGY, 2011, 36 (10) :5886-5898
[4]   Thermodynamic analysis and thermoeconomic optimization of a dual pressure combined cycle power plant with a supplementary firing unit [J].
Ahmadi, Pouria ;
Dincer, Ibrahim .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (05) :2296-2308
[5]   Exergy analysis of a 420 MW combined cycle power plant [J].
Ameri, M. ;
Ahmadi, P. ;
Khanmohammadi, S. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (02) :175-183
[6]   Enhancing the efficiency and power of the triple-pressure reheat combined cycle by means of gas reheat, gas recuperation, and reduction of the irreversibility in the heat recovery steam generator [J].
Bassily, A. M. .
APPLIED ENERGY, 2008, 85 (12) :1141-1162
[7]   Modeling, analysis, and modifications of different GT cooling techniques for modern commercial combined cycle power plants with reducing the irreversibility of the HRSG [J].
Bassily, A. M. .
APPLIED THERMAL ENGINEERING, 2013, 53 (01) :131-146
[8]  
Bejan A, 1996, THERMAL DESIGN OPTIM
[9]   Sensitivity analysis of exergy destruction in a real combined cycle power plant based on advanced exergy method [J].
Boyaghchi, Fateme Ahmadi ;
Molaie, Hanieh .
ENERGY CONVERSION AND MANAGEMENT, 2015, 99 :374-386
[10]   Avoidable thermodynamic inefficiencies and costs in an externally fired combined cycle power plant [J].
Cziesla, F ;
Tsatsaronis, G ;
Gao, ZL .
ENERGY, 2006, 31 (10-11) :1472-1489