Hybrid fast damping control strategy for doubly fed induction generators against power system inter-area oscillations

被引:6
|
作者
Liao, Kai [1 ]
Xu, Yan [1 ]
Wang, Yao [2 ]
He, Zhengyou [3 ]
Marzooghi, Hesamoddin [4 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, 50 Nanyang Ave, Singapore, Singapore
[2] Southwest Minzu Univ, Sch Elect & Informat Engn, Chengdu 610041, Sichuan, Peoples R China
[3] Southwest Jiaotong Univ, Sch Elect Engn, Chengdu 611756, Sichuan, Peoples R China
[4] CQ Univ, Sch Engn & Technol, Brisbane, Qld 4000, Australia
关键词
asynchronous generators; power system stability; bang-bang control; reactive power control; frequency-domain analysis; wind power plants; power generation control; hybrid fast damping control strategy; doubly fed induction generators; power system inter-area oscillations; bang-bang modulation; inter-area oscillations; active power modulation; torsional oscillations; DFIG reactive power; system critical oscillation mode; detected critical oscillation mode; lead phase; frequency domain analysis; detailed dynamic model; comprehensive test; modified two-area system; aggregated wind farm; operation point variation; identification errors; WIND GENERATION; TURBINES; SIGNALS;
D O I
10.1049/iet-rpg.2017.0196
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Here, a hybrid fast damping control strategy based on bang-bang modulation is proposed for doubly fed induction generators (DFIGs) against inter-area oscillations. Since the changes in active power modulation of DFIG may result in its interactive effect with torsional oscillations, this study relies on the modulation of DFIG reactive power to rapidly attenuate the system's critical oscillation mode. In order to overcome the buffeting of the bang-bang modulation, the proposed control strategy is designed as a hybrid scheme consisting of three operating modes which are switched based on the amplitude of the detected critical oscillation mode. The required lead phase for the proposed control strategy is determined using frequency domain analysis using detailed dynamic model of the DFIG. A comprehensive test is carried out by conducting simulation studies on a modified two-area system including an aggregated wind farm. It has been shown that the proposed strategy damps inter-area oscillations much quicker than the conventional continuous damping controller. Simulation results also showed that the control scheme is robust to the operation point variation and identification errors for practical application.
引用
收藏
页码:463 / 471
页数:9
相关论文
共 50 条
  • [31] Intelligent control of inter-area oscillations in power systems
    Pugliese, P
    Sbrizzai, R
    Trovato, M
    LaScala, M
    MELECON '96 - 8TH MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, PROCEEDINGS, VOLS I-III: INDUSTRIAL APPLICATIONS IN POWER SYSTEMS, COMPUTER SCIENCE AND TELECOMMUNICATIONS, 1996, : 737 - 741
  • [32] WAMS Based Damping Control of Inter-area Oscillations Employing Energy Storage System
    Ma, Jing
    Wang, Tong
    Thorp, James S.
    Wang, Zengping
    Yang, Qixun
    Phadke, A. G.
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2012, 12 (02) : 33 - 40
  • [33] A Novel System-Centric Intelligent Adaptive Control Architecture for damping Inter-area mode oscillations in Power System
    Swann, Gerald
    Kamalasadan, Sukumar
    2010 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2010,
  • [34] Wide-area robust control for damping multiple inter-area oscillations
    Chen, He
    Chen, Jing
    Chen, Xiying
    Bai, Hong
    Guo, Zhizhong
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 627 - +
  • [35] Wide-area Damping Control for Inter-area Oscillations: A Comprehensive Review
    Younis, Mohamed Ramadan
    Iravani, Reza
    2013 IEEE ELECTRICAL POWER & ENERGY CONFERENCE (EPEC), 2013,
  • [36] Selection and design of a TCSC control signal in damping power system inter-area oscillations for multiple operating conditions
    Fan, LL
    Feliachi, A
    Schoder, K
    ELECTRIC POWER SYSTEMS RESEARCH, 2002, 62 (02) : 127 - 137
  • [37] Nonlinear Coordinated Control of HVDC and TCSC for Damping Inter-Area Oscillations of Parallel AC/DC Power System
    Shi, Fang
    Wang, Jie
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (06): : 6190 - 6196
  • [38] Model Prediction Adaptive Control of Inter-Area Oscillations in Multi-Generators Power Systems
    Wang, Lin
    Cheung, Helen
    Hamlyn, Alexander
    Cheung, Richard
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 4323 - 4329
  • [39] Evaluation of Residue Based Power Oscillation Damping Control of Inter-area Oscillations for Static Power Sources
    Adamczyk, A.
    Teodorescu, R.
    Iov, F.
    Kjaer, P. C.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [40] The impact of wind farms with doubly fed induction generators on power system electromechanical oscillations
    Jafarian, M.
    Ranjbar, A. M.
    RENEWABLE ENERGY, 2013, 50 : 780 - 785